RESEARCH AND EDUCATION Comparison of strength of milled and conventionally processed PMMA complete-arch implant-supported immediate interim fixed dental prostheses

被引:12
作者
Angelara, Konstantina [1 ]
Bratos, Manuel [2 ,3 ]
Sorensen, John A. [4 ,5 ,6 ]
机构
[1] UT Hlth Sci Ctr, Dept Comprehens Dent, San Antonio, TX USA
[2] Univ Washington, Sch Dent, Dept Restorat Dent, Seattle, WA USA
[3] Private Practice, Madrid, Spain
[4] Univ Washington, Sch Dent, Dept Restorat Dent, Seattle, WA USA
[5] Univ Washington, Sch Dent, Biomimet Biomat Biophoton Biomech & Technol Lab B4, Seattle, WA USA
[6] 1959 NE Pacific St,Box 357456, Seattle, WA 98195 USA
关键词
PROVISIONAL RESTORATIONS; CAD/CAM; REHABILITATION; MAXILLA;
D O I
10.1016/j.prosdent.2021.04.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. A typical conversion process of a complete-arch immediate loading protocol entails preparing holes in a complete denture for connection to interim copings, which reduces the strength of the prosthesis. The excellent mechanical properties of milled polymethyl methacrylate (PMMA) disks may provide interim prostheses with improved strength. Purpose. The purpose of this in vitro study was to measure the flexural strength and failure load of simulated acrylic resin immediate implant-supported interim prostheses fabricated by conventional processing and computer-aided manufacturing. Material and methods. A master patient model was created with an acrylic resin base and 2 BioHorizons Internal 4.5-mm-diameter implants placed with a 21.5-mm span and multiunit abutments (MUA) tightened to place. Two groups with different prosthodontic designs were used: one represented the standard fixed prosthesis with support at each end (noncantilever, NC), and the other group represented the cantilever portion of the prosthesis (cantilever, C). Two connection designs of prosthesis blocks to MUA abutments were evaluated: one with typical holes in the prosthesis for capturing interim copings and one with a low-profile coping. For the heat-processed PMMA groups (HP/NC and HP/C), wax patterns were milled, and heat-polymerized denture base PMMA prostheses were processed. The milled PMMA groups (M/NC and M/C) were milled from a tooth-shaded PMMA disk for the prosthesis blocks. The milled low-profile groups (Mlp/NC and Mlp/C) had identical dimensions except that connection to the low-profile coping was designed with a cement space and a narrow diameter screw access hole and was milled from a PMMA disk. The failure load (N) of the cantilever prostheses was recorded, and for NC groups, the 3-point flexural strength formula (MPa) was calculated. The Weibull modulus, characteristic strength, and summary statistics were computed, and the groups were statistically analyzed with ANOVA and the post hoc Tukey test (a=.05). Results. The mean flexural strengths (MPa) were HP/NC=91.35 +/- 18.92; M/NC=143.94 +/- 36.79; Mlp/ NC=117.06 +/- 13.86. Significant differences were found among groups (P<.001). Mean failure loads (N) and Weibull modulus (WM) of cantilever prosthesis strengths were for HP/C=512.66, WM=5.597; M/C=695.06, WM=4.875; Mlp/C=254.97, WM=1.797 (P<.001). Conclusions. Implant fixed interim structures milled from high-density PMMA blanks had a 35% higher flexural strength for both the standard prostheses and the cantilever prostheses than heat-processed denture base PMMA. The low-profile coping design was stronger than the heat-processed material, and the failure point was relocated from the lateral walls to the cervical margin area. (J Prosthet Dent 2023;129:221-7)
引用
收藏
页码:221 / 227
页数:7
相关论文
共 20 条
[1]   Fracture strength of temporary fixed partial dentures: CAD/CAM versus directly fabricated restorations [J].
Alt, Vanessa ;
Hannig, Matthias ;
Woestmann, Bernd ;
Balkenhol, Markus .
DENTAL MATERIALS, 2011, 27 (04) :339-347
[2]   Digital dentistry: an overview of recent developments for CAD/CAM generated restorations [J].
Beuer, F. ;
Schweiger, J. ;
Edelhoff, D. .
BRITISH DENTAL JOURNAL, 2008, 204 (09) :505-511
[3]  
Beuer F, 2011, INT J PERIODONT REST, V31, P185
[4]  
Del Fabbro M, 2006, INT J PERIODONT REST, V26, P249
[5]   Frequency and Type of Prosthetic Complications Associated with Interim, Immediately Loaded Full-Arch Prostheses: A 2-Year Retrospective Chart Review [J].
Drago, Carl .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (06) :433-439
[6]  
Gallucci GO, 2004, INT J ORAL MAX IMPL, V19, P524
[7]  
Güth JF, 2012, J PROSTHET DENT, V107, P1, DOI 10.1016/S0022-3913(11)00171-5
[8]   Characteristic strength, Weibull modulus, and failure probability of fused silica glass [J].
Klein, Claude A. .
OPTICAL ENGINEERING, 2009, 48 (11)
[9]  
Lodding DW, 1997, CURR OPIN COSMET D, V4, P16
[10]  
Morton D, 2004, INT J ORAL MAX IMPL, V19, P103