Programming Levels and Speech Perception in Pediatric Cochlear Implant Recipients With Enlarged Vestibular Aqueduct or GJB2 Mutation

被引:1
|
作者
Jahn, Kelly N. [1 ]
Morse-Fortier, Charlotte [2 ]
Griffin, Amanda M. [3 ]
Faller, David [3 ]
Cohen, Michael S. [4 ]
Kenna, Margaret A. [3 ]
Doney, Elizabeth [2 ]
Arenberg, Julie G. [2 ,5 ]
机构
[1] Univ Texas Dallas, Dept Speech Language & Hearing, Richardson, TX USA
[2] Massachusetts Eye & Ear, Audiol Div, Boston, MA 02114 USA
[3] Boston Childrens Hosp, Dept Otolaryngol & Commun Enhancement, Boston, MA USA
[4] Harvard Med Sch, Dept Otolaryngol Head & Neck Surg, Boston, MA USA
[5] Massachusetts Eye & Ear, 243 Charles St, Boston, MA 02114 USA
基金
美国国家卫生研究院;
关键词
Cochlear implant; Electrode-neuron interface; Etiology; EVA; GJB2; Pediatric; Programming; Speech perception; ELECTRODE-NEURON INTERFACE; HEARING-LOSS; CHILDREN; CT; HISTOPATHOLOGY; VALIDATION; USERS; MR;
D O I
10.1097/MAO.0000000000003879
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
ObjectiveTo determine the relationship between hearing loss etiology, cochlear implant (CI) programming levels, and speech perception performance in a large clinical cohort of pediatric CI recipients.Study DesignRetrospective chart review.SettingTertiary care hospitals.PatientsA total of 136 pediatric CI recipients (218 ears) were included in this study. All patients had diagnoses of either enlarged vestibular aqueduct (EVA) or GJB2 (Connexin-26) mutation confirmed via radiographic data and/or genetic reports. All patients received audiologic care at either Boston Children's Hospital or Massachusetts Eye and Ear in Boston, MA, between the years 1999 and 2020.Main Outcome MeasuresElectrode impedances and programming levels for each active electrode and speech perception scores were evaluated as a function of etiology (EVA or GJB2 mutation).ResultsChildren with EVA had significantly higher impedances and programming levels (thresholds and upper stimulation levels) than the children with GJB2 mutation. Speech perception scores did not differ as a function of etiology in this sample; rather, they were positively correlated with duration of CI experience (time since implantation).ConclusionsDifferences in electrode impedances and CI programming levels suggest that the electrode-neuron interface varies systematically as a function of hearing loss etiology in pediatric CI recipients with EVA and those with GJB2 mutation. Time with the CI was a better predictor of speech perception scores than etiology, suggesting that children can adapt to CI stimulation with experience.
引用
收藏
页码:E273 / E280
页数:8
相关论文
共 21 条
  • [1] Long term speech perception after cochlear implant in pediatric patients with GJB2 mutations
    Yoshida, Haruo
    Takahashi, Haruo
    Kanda, Yukihiko
    Usami, Shin-ichi
    AURIS NASUS LARYNX, 2013, 40 (05) : 435 - 439
  • [2] Enlarged Vestibular Aqueduct: Hearing Progression and Cochlear Implant Candidacy in Pediatric Patients
    Hodge, Sarah E.
    Thompson, Nicholas J.
    Park, Lisa R.
    Brown, Kevin D.
    OTOLOGY & NEUROTOLOGY, 2021, 42 (01) : 203 - 206
  • [3] Auditory Detection Thresholds and Cochlear Resistivity Differ Between Pediatric Cochlear Implant Listeners With Enlarged Vestibular Aqueduct and Those With Connexin-26 Mutations
    Jahn, Kelly N.
    Bergan, Molly D.
    Arenberg, Julie G.
    AMERICAN JOURNAL OF AUDIOLOGY, 2020, 29 (01) : 23 - 34
  • [4] High Prevalence of the Connexin 26 (GJB2) Mutation in Chinese Cochlear Implant Recipients
    Chen, Dongye
    Chen, Xiaowei
    Cao, Keli
    Zuo, Jin
    Jin, Xin
    Wei, Caogang
    Fang, Fude
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 2009, 71 (04): : 212 - 215
  • [5] Prevalence of GJB2 gene mutation in 330 cochlear implant patients in the Jiangsu province
    Shi, L.
    Chen, J.
    Li, J.
    Wei, X.
    Gao, X.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2016, 130 (10) : 902 - 906
  • [6] The effect of GJB2 and SLC26A4 gene mutations on rehabilitative outcomes in pediatric cochlear implant patients
    Yan, Yu-jun
    Li, Yun
    Yang, Tao
    Huang, Qi
    Wu, Hao
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2013, 270 (11) : 2865 - 2870
  • [7] Association of GJB2 gene mutation with cochlear implant performance in genetic non-syndromic hearing loss
    Karamert, Recep
    Bayazit, Yildirim A.
    Altinyay, Senay
    Yilmaz, Akin
    Menevse, Adnan
    Gokdogan, Ozan
    Gokdogan, Cagil
    Ant, Ayca
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2011, 75 (12) : 1572 - 1575
  • [8] Intraoperative Round Window Electrocochleography and Speech Perception Outcomes in Pediatric Cochlear Implant Recipients
    Formeister, Eric J.
    McClellan, Joseph H.
    Merwin, William H., III
    Iseli, Claire E.
    Calloway, Nathan H.
    Teagle, Holly F. B.
    Buchman, Craig A.
    Adunka, Oliver F.
    Fitzpatrick, Douglas C.
    EAR AND HEARING, 2015, 36 (02) : 249 - 260
  • [9] Benefit and predictive factors for speech perception outcomes in pediatric bilateral cochlear implant recipients
    Chang, Young-Soo
    Hong, Sung Hwa
    Kim, Eun Yeon
    Choi, Ji Eun
    Chung, Won-Ho
    Cho, Yang-Sun
    Moon, Il Joon
    BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2019, 85 (05) : 571 - 577
  • [10] Spectral Modulation Detection Performance and Speech Perception in Pediatric Cochlear Implant Recipients
    Davidson, Lisa S.
    Geers, Ann E.
    Uchanski, Rosalie M.
    AMERICAN JOURNAL OF AUDIOLOGY, 2021, 30 (04) : 1076 - 1087