Finite element analysis and clinical application of 3D-printed Ti alloy implant for the reconstruction of mandibular defects

被引:6
|
作者
Xue, Runqi [1 ]
Lai, Qingguo [1 ]
Xing, Hongyu [3 ]
Zhong, Chiyang [1 ]
Zhao, Yixuan [2 ]
Zhu, Kaiwen [2 ]
Deng, Yanwei [1 ]
Liu, Chengbin [4 ]
机构
[1] Shandong Univ, Dept Oral & Maxillofacial Surg, Hosp 2, Jinan 250033, Shandong Provin, Peoples R China
[2] Shandong Univ, Jinan, Shandong Provin, Peoples R China
[3] Shandong Jinan Univ, Sch Mech & Elect Engn, Jinan, Shandong Provin, Peoples R China
[4] Zaozhuang Municipal Hosp, Zaozhuang, Shandong Provin, Peoples R China
关键词
3D printing; Maxillofacial surgery; Reconstruction; Finite element analysis; Biomechanics; Personalized medicine; PLATES; FRACTURE; BONE;
D O I
10.1186/s12903-024-03857-y
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThe reconstruction of segmental defect of the mandible has always been a challenge. The customized reconstruction plate without a bone graft is also considered a transitional means of rehabilitation and reconstruction in some cases.MethodsThis study evaluated the biomechanical behaviors of customized plates with different structural designs comparing with commercial plates using the finite element method in reconstrution of the lateral mandible defect.ResultsSimulations revealed the stress state in the plate bodies, bone tissues and screws were associated with the width, height, thickness of the plates as well as the distribution of screws. In all of the groups, the system of 16 mm-high, 2.8 mm-thick customized reconstruction plate with 10 screws was considered to be the most ideal design because of the most harmonious biomechanical state. What's more, the stress shielding effects were not obvious in this experiment. Based on the above findings, we conducted a clinical case analysis to verify the mechanical properties of customized reconstruction and obtained a satisfactory operation result.ConclusionsThe results show that by adjusting the contour parameters of the reconstruction plates, an ideal and reliable customized plate can be manufactured. And the customized 3D-printed Ti alloy implant will be a new way to achieve mandibular reconstruction in patients unable to perform autologous bone graft surgery.Trial registrationThe present trial has been registered with ChiCTR, the registration number is ChiCTR 2,000,038,973 on 11/10/2020.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] The use of customized 3D-printed mandibular prostheses with pressure-reducing device: A clinical trial
    Chen, Chun-Feng
    Chen, Chun-Ming
    Huang, Wei-Chin
    Liu, Sung-Ho
    Wang, Ling-Lin
    Liu, Pei-Feng
    Chen, Ping-Ho
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2024, 46 (07): : 1614 - 1624
  • [32] Biomechanical behavior of the three-dimensionally printed surgical plates for mandibular defect reconstruction: a finite element analysis
    Wang, Chao-Fei
    Liu, Shuo
    Hu, Lei-Hao
    Yu, Yao
    Peng, Xin
    Zhang, Wen-Bo
    COMPUTER ASSISTED SURGERY, 2023, 28 (01)
  • [33] Applying 3D-Printed Porous Ti6Al4V Prostheses to Repair Osteomyelitis-Induced Partial Bone Defects of Lower Limbs: Finite Element Analysis and Clinical Outcomes
    Liu, Bingchuan
    Tan, Qizhao
    Wang, Zhengguang
    Hou, Guojin
    Wang, Caimei
    Tian, Yun
    ORTHOPAEDIC SURGERY, 2024, : 115 - 124
  • [34] Finite element analysis of 3D-Printed Acrylonitrile Styrene Acrylate (ASA) with Ultrasonic material characterization
    Yap, Yee Ling
    Toh, William
    Koneru, Rahul
    Chua, Zhong Yang
    Lin, Kehua
    Yeoh, Kirk Ming
    Lim, Chin Mian
    Lee, Jia Shing
    Plemping, Nur Adilah
    Lin, Rongming
    Ng, Teng Yong
    Chan, Keen Ian
    Guang, Huanyu
    Chan, Wai Yew Brian
    Teong, Soo Soon
    Zheng, Guoying
    INTERNATIONAL JOURNAL OF COMPUTATIONAL MATERIALS SCIENCE AND ENGINEERING, 2019, 8 (01)
  • [35] Novel and accurate 3D-Printed surgical guide for mandibular reconstruction with integrated dental implants
    Miljanovic, Dajana
    Seyedmahmoudian, Mehdi
    Horan, Ben
    Stojcevski, Alex
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 151
  • [36] The accuracy of patient specific implant prebented with 3D-printed rapid prototype model for orbital wall reconstruction
    Kim, Young Chul
    Jeong, Woo Shik
    Park, Tae-Kyung
    Choi, Jong Woo
    Koh, Kyung S.
    Oh, Tae Suk
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (06) : 928 - 936
  • [37] A 3D-printed Lateral Skull Base Implant for Repair of Tegmen Defects: A Case Series
    VanKoevering, Kyle Keith
    Gao, Rebecca Weiwei
    Ahmed, Sameer
    Green, Glenn Edward
    Arts, Henry Alexander
    OTOLOGY & NEUROTOLOGY, 2020, 41 (08) : 1108 - 1115
  • [38] Finite element modeling of 3D-printed part with cellular internal structure using homogenized properties
    Bhandari, Sunil
    Lopez-Anido, Roberto
    PROGRESS IN ADDITIVE MANUFACTURING, 2019, 4 (02) : 143 - 154
  • [39] Validation of Low Cost Patient Specific Implant Design Using Finite Element Analysis (FEA) for Reconstruction of Segmental Mandibular Defects: A Case Report and Literature Review
    Chakravarthy, Chitra
    Patil, Ravi S.
    Wagdargi, Shivraj
    Malyala, Santosh Kumar
    Sofhia, Daisy Arahna
    Babu, Chethan V.
    Koppunur, Rakesh
    Mundodi, Aishwarya
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2024, 23 (05) : 1096 - 1105
  • [40] Biomechanics of internal connection in mandibular implant-supported prosthesis under effect of loadings and number of implants: A 3D finite element analysis
    Dayrell, Andreza Costa
    Pimenta de Araujo, Cintia Tereza
    Rocha, Ricardo Lopes
    Isolan, Cristina Pereira
    Noritomi, Pedro Yoshito
    Mesquita, Marcelo Ferraz
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 148