Mixed methods usability evaluation of an assistive wearable robotic hand orthosis for people with spinal cord injury

被引:7
|
作者
Dittli, Jan [1 ]
Meyer, Jan T. [1 ]
Gantenbein, Jessica [1 ]
Buetzer, Tobias [1 ]
Ranzani, Raffaele [1 ]
Linke, Anita [2 ]
Curt, Armin [2 ]
Gassert, Roger [1 ,3 ]
Lambercy, Olivier [1 ,3 ]
机构
[1] Swiss Fed Inst Technol, Dept Hlth Sci & Technol, Rehabil Engn Lab, Lengghalde 5, CH-8008 Zurich, Switzerland
[2] Balgrist Univ Hosp, Spinal Cord Injury Ctr, Forchstr 340, CH-8008 Zurich, Switzerland
[3] Singapore ETH Ctr, Future Hlth Technol Programme, CREATE Campus,1 Create Way,06-01 CREATE Tower, Singapore 138602, Singapore
关键词
Usability; Robotic hand orthosis; Mixed methods; Wearable robots; EXOSKELETON;
D O I
10.1186/s12984-023-01284-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BackgroundRobotic hand orthoses (RHO) aim to provide grasp assistance for people with sensorimotor hand impairment during daily tasks. Many of such devices have been shown to bring a functional benefit to the user. However, assessing functional benefit is not sufficient to evaluate the usability of such technologies for daily life application. A comprehensive and structured evaluation of device usability not only focusing on effectiveness but also efficiency and satisfaction is required, yet often falls short in existing literature. Mixed methods evaluations, i.e., assessing a combination of quantitative and qualitative measures, allow to obtain a more holistic picture of all relevant aspects of device usability. Considering these aspects already in early development stages allows to identify design issues and generate generalizable benchmarks for future developments.MethodsWe evaluated the short-term usability of the RELab tenoexo, a RHO for hand function assistance, in 15 users with tetraplegia after a spinal cord injury through a comprehensive mixed methods approach. We collected quantitative data using the Action Research Arm Test (ARAT), the System Usability Scale (SUS), and timed tasks such as the donning process. In addition, qualitative data were collected through semi-structured interviews and user observations, and analyzed with a thematic analysis to enhance the usability evaluation. All insights were attributed and discussed in relation to specifically defined usability attributes such as comfort, ease of use, functional benefit, and safety.ResultsThe RELab tenoexo provided an immediate functional benefit to the users, resulting in a mean improvement of the ARAT score by 5.8 points and peaking at 15 points improvement for one user (clinically important difference: 5.7 points). The mean SUS rating of 60.6 represents an adequate usability, however, indicating that especially the RHO donning (average task time = 295 s) was perceived as too long and cumbersome. The participants were generally very satisfied with the ergonomics (size, dimensions, fit) of the RHO. Enhancing the ease of use, specifically in donning, increasing the provided grasping force, as well as the availability of tailoring options and customization were identified as main improvement areas to promote RHO usability.ConclusionThe short-term usability of the RELab tenoexo was thoroughly evaluated with a mixed methods approach, which generated valuable data to improve the RHO in future iterations. In addition, learnings that might be transferable to the evaluation and design of other RHO were generated, which have the potential to increase the daily life applicability and acceptance of similar technologies.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Gait Training Using a Wearable Robotic Device for Non-Traumatic Spinal Cord Injury: A Case Report
    Yoshikawa, Kenichi
    Mutsuzaki, Hirotaka
    Koseki, Kazunori
    Endo, Yusuke
    Hashizume, Yuko
    Nakazawa, Ryo
    Aoyama, Toshiyuki
    Yozu, Arito
    Kohno, Yutaka
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2020, 11
  • [42] Comparative validity of energy expenditure prediction algorithms using wearable devices for people with spinal cord injury
    Yousif J. Shwetar
    Akhila L. Veerubhotla
    Zijian Huang
    Dan Ding
    Spinal Cord, 2020, 58 : 821 - 830
  • [43] Qualitative evaluation of a Community Peer Support Service for people with spinal cord injury
    B M Haas
    L Price
    J A Freeman
    Spinal Cord, 2013, 51 : 295 - 299
  • [44] Adaptation to Spanish and Validity by Wearable Sensors of the Physical Activity Recall Assessment for People with Spinal Cord Injury
    Castan, Alex
    Opisso, Eloy
    Chamarro, Andres
    Ginis, Kathleen A. Martin
    Sauri, Joan
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2023, 27 (04) : 362 - 376
  • [45] Qualitative evaluation of a Community Peer Support Service for people with spinal cord injury
    Haas, B. M.
    Price, L.
    Freeman, J. A.
    SPINAL CORD, 2013, 51 (04) : 295 - 299
  • [46] Comparative validity of energy expenditure prediction algorithms using wearable devices for people with spinal cord injury
    Shwetar, Yousif J.
    Veerubhotla, Akhila L.
    Huang, Zijian
    Ding, Dan
    SPINAL CORD, 2020, 58 (07) : 821 - 830
  • [47] Benefits and barriers to return to education and relationship to quality of life for people living with spinal cord injury: Results of a mixed methods study
    Hsieh, Shelly
    De Simone, Adria
    Dyson-Hudson, Trevor
    O'Neill, John
    Botticello, Amanda
    Chen, Ada
    Kirshblum, Steven
    JOURNAL OF SPINAL CORD MEDICINE, 2025, 48 (02): : 327 - 337
  • [48] A Wearable Vibration Glove for Improving Hand Sensation in Persons with Spinal Cord Injury Using Passive Haptic Rehabilitation
    Estes, L. T. C. Tanya
    Backus, Deborah
    PROCEEDINGS OF THE 2015 9TH INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING TECHNOLOGIES FOR HEALTHCARE (PERVASIVEHEALTH), 2015, : 37 - 44
  • [50] Comparison of methods to assess energy expenditure and physical activity in people with spinal cord injury
    Tanhoffer, Ricardo A.
    Tanhoffer, Aldre I. P.
    Raymond, Jacqueline
    Hills, Andrew P.
    Davis, Glen M.
    JOURNAL OF SPINAL CORD MEDICINE, 2012, 35 (01): : 35 - 45