Diagnostic Efficacy of Renal 2-D Shear Wave Elastography in Familial Mediterranean Fever Disease

被引:0
作者
Albayrak, Eda [1 ,2 ]
Akbas, Meral Gizem [1 ]
机构
[1] Tokat Gaziosmanpasa Univ, Fac Med, Dept Radiol, Tokat, Turkiye
[2] Tokat Gaziosmanpasa Univ, Med Fac, Dept Radiol, Muhittin Fisunoglu, TR-60100 Tokat, Turkiye
关键词
familial Mediterranean fever; shear wave elastography; kidneys; ultrasonography; AMYLOIDOSIS; ELASTICITY; VALUES;
D O I
10.1097/RUQ.0000000000000640
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aims of this study were to evaluate the kidneys of patients with familial Mediterranean fever (FMF) noninvasively and quantitatively using 2-D shear wave elastography (SWE) and to reveal the diagnostic efficacy of SWE in FMF-induced renal involvement. Healthy controls, FMF patients, and FMF patients with proteinuria were included in the study, and differences in renal stiffness values between the groups were examined. In addition, a relationship between age, sex, height, weight, body mass index, serum erythrocyte sedimentation rate, C-reactive protein, glomerular filtration rate, and renal stiffness values was evaluated. A total of 120 subjects, including 60 controls, 41 FMF patients without proteinuria, and 19 FMF patients with proteinuria, were enrolled in the study. Renal stiffness values were found to be significantly higher in the group with FMF compared with the control group. In addition, the values in the proteinuria group were higher than both the control group and FMF patients without proteinuria (P < 0.001). A significant positive correlation was found between the renal stiffness value and C-reactive protein. According to receiver operating characteristic analysis, the mean renal stiffness value was 7.905 kPa or greater to determine FMF-induced proteinuria. The current study shows that renal stiffness values were higher in FMF patients compared with the normal population and the values showed further increase in the presence of proteinuria, which indicates a more advanced stage of renal involvement of the disease. These findings reveal that SWE can be used as a noninvasive diagnostic tool in the diagnosis, follow-up, and evaluating the severity of FMF.
引用
收藏
页码:171 / 178
页数:8
相关论文
共 50 条
  • [31] Nutcracker syndrome in a child with familial Mediterranean fever (FMF) disease: renal ultrastructural features
    Ayhan Ozcan
    Ipek Isık Gonul
    Onur Sakallioglu
    Emin Oztas
    International Urology and Nephrology, 2009, 41 : 1047 - 1053
  • [32] Exploring the combined diagnostic role of serum MBL in association with renal resistive index and renal shear wave elastography in diabetic kidney disease patients
    Enas Ahmed Osman
    Khaled Mabrouk
    Ahmed Abdelsamie Mahmoud
    Medhat Madbouly
    Mohamed Moharam Mohamed Hussin
    Osama Mosbah
    Nevine Sherif
    Mohammed Ghanem Gaber
    Farida M. Khanany
    Beni-Suef University Journal of Basic and Applied Sciences, 14 (1)
  • [33] Chinese Ultrasound Doctors Association Guideline on Operational Standards for 2-D Shear Wave Elastography Examination of Musculoskeletal Tissues
    Zhu, Jiaan
    Qiu, Li
    Ta, Dean
    Hua, Xing
    Liu, Hongmei
    Zhang, Huabin
    Li, Jia
    Wang, Yuexiang
    Xi, Zhanguo
    Zheng, Yuanyi
    Shan, Yong
    Liu, Bingyan
    Huang, Weijun
    Liu, Weiyong
    Hao, Shaoyun
    Cui, Ligang
    Cai, Jin
    Zhang, Wei
    Zhang, Chao
    Chen, Shuqiang
    Wei, An
    Dong, Fajin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (02) : 175 - 183
  • [34] Diagnostic Accuracy of 2D-Shear Wave Elastography for Liver Fibrosis Severity: A Meta-Analysis
    Jiang, Tian'an
    Tian, Guo
    Zhao, Qiyu
    Kong, Dexing
    Cheng, Chao
    Zhong, Liyun
    Li, Lanjuan
    PLOS ONE, 2016, 11 (06):
  • [35] Establishment and Validation of a Predictive Model for Sarcopenia Based on 2-D Ultrasound and Shear Wave Elastography in the Medial Gastrocnemius Muscle
    Wang, Zecheng
    Xu, Zhenhong
    Zhong, Huohu
    Zheng, Xinying
    Yan, Lisheng
    Lyu, Guorong
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (09) : 1299 - 1307
  • [36] Evaluation of the Liver and Pancreas by 2D Shear Wave Elastography in Pediatric Wilson's Disease
    Yavuz, Sibel
    Piskin, Ferhat Can
    Oktay, Cemil
    Soyupak, Sureyya
    Tumgor, Gokhan
    TURKISH JOURNAL OF GASTROENTEROLOGY, 2022, 33 (02) : 161 - 167
  • [37] Differentiating solid breast masses: comparison of the diagnostic efficacy of shear wave elastography and magnetic resonance imaging
    Farghadani, Maryam
    Barikbin, Rozbeh
    Rezaei, Mostafa Haji
    Hekmatnia, Ali
    Aalinezhad, Marzieh
    Zare, Hosein
    DIAGNOSIS, 2021, 8 (03) : 382 - 387
  • [38] Diagnostic performance of 2D-shear wave elastography in the diagnosis of breast cancer: a clinical appraisal of cutoff values
    Bartolotta, Tommaso Vincenzo
    Orlando, Alessia Angela Maria
    Dimarco, Mariangela
    Zarcaro, Calogero
    Ferraro, Fabiola
    Cirino, Alessandra
    Matranga, Domenica
    Vieni, Salvatore
    Cabibi, Daniela
    RADIOLOGIA MEDICA, 2022, 127 (11): : 1209 - 1220
  • [39] Diagnostic performance of 2D-shear wave elastography in the diagnosis of breast cancer: a clinical appraisal of cutoff values
    Tommaso Vincenzo Bartolotta
    Alessia Angela Maria Orlando
    Mariangela Dimarco
    Calogero Zarcaro
    Fabiola Ferraro
    Alessandra Cirino
    Domenica Matranga
    Salvatore Vieni
    Daniela Cabibi
    La radiologia medica, 2022, 127 : 1209 - 1220
  • [40] Diagnostic value of real-time shear wave elastography in children with chronic kidney disease
    Liu, Qin
    Wang, Zhengrong
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2021, 77 (03) : 287 - 293