Description and validation of an equilibrium dialysis ID-LC-MS/MS candidate reference measurement procedure for free thyroxine in human serum

被引:7
|
作者
Jansen, Heleen I. [1 ,2 ,3 ]
van der Steen, Rob [4 ]
Brandt, Andre [4 ]
Olthaar, Andre J. [4 ]
Vesper, Hubert W. [5 ]
Shimizu, Eri [6 ]
Heijboer, Annemieke C. [1 ,2 ,3 ,7 ]
Van Uytfanghe, Katleen [8 ]
van Herwaarden, Antonius E. [4 ,9 ]
机构
[1] Amsterdam UMC Locat Vrije Univ Amsterdam, Dept Clin Chem, Endocrine Lab, Amsterdam, Netherlands
[2] Amsterdam UMC Locat Univ Amsterdam, Dept Clin Chem, Endocrine Lab, Amsterdam, Netherlands
[3] Amsterdam Gastroenterol Endocrinol & Metab, Amsterdam, Netherlands
[4] Radboud Univ Nijmegen, Dept Lab Med, Med Ctr, Nijmegen, Netherlands
[5] CDCP, Div Lab Sci, Atlanta, GA USA
[6] Reference Mat Inst Clin Chem Stand, Kanagawa, Japan
[7] Amsterdam Reprod & Dev Res Inst, Amsterdam, Netherlands
[8] Univ Ghent, Fac Pharmaceut Sci, Dept Bioanal, Lab Toxicol, Ghent, Belgium
[9] Radboud Univ Nijmegen, Dept Lab Med, Med Ctr, Geert Grooteplein Zuid 10, NL-6525 GA Nijmegen, Netherlands
关键词
conventional reference measurement procedure; free thyroxine; LC-MS; MS; standardization; THYROID-FUNCTION TESTS; MASS-SPECTROMETRY; STANDARDIZATION;
D O I
10.1515/cclm-2022-1134
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives Free thyroxine (FT4) in serum is routinely measured in clinical practice to diagnose and monitor thyroid disease. Due to its concentration in picomolar range and the delicate equilibrium of free and protein-bound T4, accurate measurement is challenging. As a consequence, large inter-method differences in FT4 results exists. Optimal method design and standardization of the FT4 measurement is therefore necessary. The IFCC Working Group for Standardization of Thyroid Function Tests proposed a reference system with a conventional reference measurement procedure (cRMP) for FT4 in serum. In this study, we describe our FT4 candidate cRMP and its validation in clinical samples.Methods This candidate cRMP is based on equilibrium dialysis (ED) combined with determination of T4 with an isotope-dilution liquid chromatography tandem mass-spectrometry (ID-LC-MS/MS) procedure and was developed according to the endorsed conventions. Its accuracy, reliability, and comparability was investigated using human sera.Results It was shown that the candidate cRMP adhered to the conventions and its accuracy, precision, and robustness were adequate in serum of healthy volunteers.Conclusions Our candidate cRMP measures FT4 accurately and performs well in serum matrix.
引用
收藏
页码:1605 / 1611
页数:7
相关论文
共 50 条
  • [1] Development of an equilibrium dialysis ID-UPLC-MS/MS candidate reference measurement procedure for free thyroxine in human serum
    Ribera, Ashley
    Zhang, Li
    Dabbs-Brown, Amonae
    Sugahara, Otoe
    Poynter, Krista
    van Uytfanghe, Katleen
    Shimizu, Eri
    Herwaarden, Antonius E. van
    Botelho, Julianne C.
    Danilenko, Uliana
    Vesper, Hubert W.
    CLINICAL BIOCHEMISTRY, 2023, 116 : 42 - 51
  • [2] Development of a candidate reference measurement procedure by ID-LC-MS/MS for total tau protein measurement in cerebrospinal fluid (CSF)
    Giangrande, Chiara
    Vaneeckhoutte, Helene
    Boeuf, Amandine
    Lalere, Beatrice
    Hirtz, Christophe
    Lehmann, Sylvain
    Quaglia, Milena
    Delatour, Vincent
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (07) : 1235 - 1244
  • [3] Clinical application of an optimized reference measurement procedure for serum digoxin using bracketing calibration method by ID-LC-MS/MS
    Yan, Qiaofang
    Huang, Fei
    Wang, Chuyang
    Zhan, Min
    Zhang, Qiaoxuan
    Huang, Di
    Yan, Jun
    Lin, Haibiao
    Huang, Xianzhang
    Han, Liqiao
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (29) : 6909 - 6918
  • [4] Development and validation of an isotope dilution-liquid chromatography (ID-LC-MS/MS)-based candidate reference measurement procedure for total 3,3′,5-triiodothyronine in human serum
    Li, Wenya
    Gao, Bingling
    Yang, Tao
    Tang, Liping
    Song, Dan
    Li, Hongmei
    Sun, Keqi
    Xiao, Peng
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025,
  • [5] Free Cortisol Measurement in Human Serum by Combined Equilibrium Dialysis and LC-MS/MS
    Twentyman, J.
    Cradic, K.
    Grebe, S.
    Singh, R.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A190 - A190
  • [6] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of levetiracetam in human serum and plasma
    Kobel, Anja
    Schierscher, Tobias
    Singh, Neeraj
    Salzmann, Linda
    Liesch, Franziska
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1967 - 1977
  • [7] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of topiramate in human serum and plasma
    Salzmann, Linda
    Spescha, Tino
    Singh, Neeraj
    Kobel, Anja
    Fischer, Vanessa
    Schierscher, Tobias
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1942 - 1954
  • [8] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of carbamazepine in human serum and plasma
    Schierscher, Tobias
    Salzmann, Linda
    Singh, Neeraj
    Bachmann, Martina
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1301 - 1313
  • [9] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of zonisamide in human serum and plasma
    Schierscher, Tobias
    Salzmann, Linda
    Singh, Neeraj
    Wild, Janik
    Fischer, Vanessa
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1288 - 1300
  • [10] Isotope-dilution-LC-MS/MS candidate reference measurement procedure for cefepime in human serum
    Schaeffler, Judith
    Vogeser, Michael
    Habler, Katharina
    JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB, 2024, 33 : 43 - 48