SSA-optimized cascade optimal-PIDN controller for multi-area power system with RFB under deregulated environment

被引:13
作者
Rangi, Sandeep [1 ]
Jain, Sheilza [1 ]
Arya, Yogendra [2 ,3 ]
机构
[1] JC Bose Univ Sci & Technol, Dept Elect Engn, YMCA, Faridabad, Haryana, India
[2] JC Bose Univ Sci & Technol, Dept Elect Engn, YMCA, Faridabad, Haryana, India
[3] JC Bose Univ Sci & Technol, Dept Elect Engn, YMCA, Faridabad 121006, Haryana, India
关键词
cascade control; optimal control; PIDN; redox flow battery; salp swarm algorithm; LOAD FREQUENCY CONTROL; REDOX FLOW BATTERIES; AC/DC PARALLEL LINKS; ENERGY-STORAGE; AGC; IMPACT;
D O I
10.1002/oca.2962
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In today's rapidly evolving interconnected electric power system network, ancillary service such as automatic generation control (AGC) plays a critical and important role in safeguarding the system's power supply quality by establishing an equilibrium between generation and load demanded plus losses. A power system with a robust and smart AGC strategy is obligatory for better power quality and system security. Cascade control schemes cope up better with nonlinearity by tuning the gain of controller of power system amid continuous load changing. Therefore, in this article, a supplementary control approach that is, cascade optimal controller-proportional integral with derivative filter (COC-PIDN) is suggested for AGC performance advancement of the power systems under deregulated environment. The OC designed consuming full state feedback control approach acts as master controller and PIDN plays the role of slave controller. The nature inspired salp swarm algorithm is employed to adjust the PIDN parameters. Initially, the efficacy of the COC-PIDN control-method is explored on a two-area restructured reheat thermal system and then to validate its excellence and extensibility, the study is protracted to restructured two-area thermal-hydro system. Extensive analysis of the findings establishes that the dynamic performance of the COC-PIDN controller is more valuable than the OC and COC-PID approaches. The results of COC-PIDN get further improved in presence of redox flow battery. Finally, the sensitivity analysis as well the acquired results with the COC-PIDN controller with system nonlinearities demonstrate its robustness.
引用
收藏
页码:1972 / 1994
页数:23
相关论文
共 50 条
  • [21] Equilibrium Optimized AGC of Multi-Area Restructured Power System Using Cascaded Fractional Fuzzy Controller
    Aryan, Pulakraj
    Shankar, Ravi
    Ranjan, Mrinal
    2020 INTERNATIONAL CONFERENCE ON EMERGING FRONTIERS IN ELECTRICAL AND ELECTRONIC TECHNOLOGIES (ICEFEET 2020), 2020,
  • [22] Interconnected power control on unequal, deregulated multi-area power system using three-degree-of-freedom-based FOPID-PR controller
    Kumar, Rajiv
    Sharma, V. K.
    ELECTRICAL ENGINEERING, 2024, 106 (02) : 2107 - 2129
  • [23] Design of fractional order proportional integral controller for load frequency control of multi area power system under deregulated environment
    Kumar K.V.
    Ganesh V.
    International Journal of Power and Energy Conversion, 2020, 11 (03) : 223 - 247
  • [24] Performance Improvement of AGC Using Novel Controllers in a Multi-Area Solar Thermal System under Deregulated Environment
    Rajendran, Madhuvanthani
    Govindasamy, Sundar
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2024, 52 (06) : 847 - 862
  • [25] Performance Analysis of Multi-area Multi-source Power System with FOPID Controller and EVs
    Shukla, Rakesh Rajan
    Garg, Man Mohan
    Panda, Anup Kumar
    2023 IEEE IAS GLOBAL CONFERENCE ON RENEWABLE ENERGY AND HYDROGEN TECHNOLOGIES, GLOBCONHT, 2023,
  • [26] An Optimized Hybrid Fractional Order Controller for Frequency Regulation in Multi-Area Power Systems
    Mohamed, Emad A.
    Ahmed, Emad M.
    Elmelegi, Ahmed
    Aly, Mokhtar
    Elbaksawi, Osama
    Mohamed, Al-Attar Ali
    IEEE ACCESS, 2020, 8 : 213899 - 213915
  • [27] Crow Search Algorithm-Optimized Cascade Controller in a Multi-Area Thermal Wind Integrated System and Its Real-Time Validation
    Babu, Naladi Ram
    Chiranjeevi, Tirumalasetty
    Saha, Arindita
    Bhagat, Sanjeev Kumar
    Gupta, Umesh Kumar
    Vais, Ram Ishwar
    ELECTRICA, 2023, 23 (03): : 429 - +
  • [28] Decentralized load frequency controller for a multi-area interconnected power system
    Alrifai, Muthana T.
    Hassan, Mohamed F.
    Zribi, Mohamed
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2011, 33 (02) : 198 - 209
  • [29] Wind Energy Infiltrated Multi-Area Power System: Optimized 2-DOF-FOPID Controller for LFC
    Koley, Indrajit
    Datta, Asim
    Panda, Goutam Kumar
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2020, 10 (02): : 743 - 756
  • [30] Adaptive optimal wide-area controller for multi-area power system using phasor measurement unit measurements
    Joseph, Thomas
    Tyagi, Barjeev
    Kumar, Vishal
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (23) : 5284 - 5293