Impact of continuous glucose monitoring in youth with type 1 diabetes aged 15-21 years

被引:5
|
作者
Lee, Myron Andrew [1 ,2 ,3 ,4 ]
Holmes-Walker, Deborah Jane [2 ,3 ,4 ]
Farrell, Kaye [3 ]
Clark-Luccitti, Ashley [3 ]
机构
[1] Royal Prince Alfred Hosp, Sydney, NSW, Australia
[2] Westmead Hosp, Dept Diabet & Endocrinol, Westmead, NSW, Australia
[3] Westmead Hosp, Dept Diabet & Endocrinol, Diabet Transit Support Programme, Westmead, NSW, Australia
[4] Univ Sydney, Sydney Med Sch, Sydney, NSW, Australia
关键词
type; 1; diabetes; continuous glucose monitoring; youth; young adult; INSULIN-PUMP THERAPY; HYPOGLYCEMIA; ADULTS; FEAR;
D O I
10.1111/imj.15347
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background People with type 1 diabetes (T1D) aged <21 years are eligible for subsidised continuous glucose monitoring (CGM) products under the Australian National Diabetes Services Scheme. There are few real-world published studies to evaluate the benefits of CGM in young adults. Aims To perform a real-world observation study among youth with T1D to evaluate CGM use and benefits of CGM. Methods Patients at the Westmead Hospital Young Adult Diabetes Clinic aged 15-21 years who commenced CGM before July 2018 were followed for 6 months post commencement of CGM. Differences in HbA1c and glucose metrics at baseline and follow up are compared between those commencing CGM and those that did not. Results Forty-four (38%) of 115 eligible patients commenced CGM. Demographic characteristics and baseline HbA1c did not differ significantly between those started on CGM and those that did not. At 6 months, 18 (41%) of 44 patients still used CGM, with discomfort and inconvenience the most common reasons for dropout. In CGM continuers, at 6 months compared with baseline, there was no change in HbA1c (8.2% vs 8.0%; P = 0.8), coefficient of variation of glucose (38% vs 39%; P = 0.5) or percentage time in range (52% vs 58%; P = 0.3). Six-month follow-up HbA1c in CGM non-users deteriorated significantly compared with users. Mean hypoglycaemia fear scores (worry scale) were significantly decreased from baseline at 6 months (33 vs 18; P < 0.01). Conclusion There are high rates of discontinuation in CGM use among youth with T1D. At 6 months of CGM use, there was no significant change in glycaemic control, although HbA1c in non-users deteriorated significantly. Worry of hypoglycaemia was significantly decreased among those who continued CGM.
引用
收藏
页码:209 / 215
页数:7
相关论文
共 50 条
  • [21] Alarm Settings of Continuous Glucose Monitoring Systems and Associations to Glucose Outcomes in Type 1 Diabetes
    Lin, Yu Kuei
    Groat, Danielle
    Chan, Owen
    Hung, Man
    Sharma, Anu
    Varner, Michael W.
    Gouripeddi, Ramkiran
    Facelli, Julio C.
    Fisher, Simon J.
    JOURNAL OF THE ENDOCRINE SOCIETY, 2020, 4 (01)
  • [22] Impact of Carbohydrate on Glucose Variability in Patients with Type 1 Diabetes Assessed Through Professional Continuous Glucose Monitoring: A Retrospective Study
    Lin, Yi-Hsuan
    Huang, Yu-Yao
    Chen, Hsin-Yun
    Hsieh, Sheng-Hwu
    Sun, Jui-Hung
    Chen, Szu-Tah
    Lin, Chia-Hung
    DIABETES THERAPY, 2019, 10 (06) : 2289 - 2304
  • [23] Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials
    Dicembrini, I.
    Cosentino, C.
    Monami, M.
    Mannucci, E.
    Pala, L.
    ACTA DIABETOLOGICA, 2021, 58 (04) : 401 - 410
  • [24] Accuracy of continuous glucose monitoring during exercise-related hypoglycemia in individuals with type 1 diabetes
    Maytham, Kaisar
    Hagelqvist, Per G.
    Engberg, Susanne
    Forman, Julie L.
    Pedersen-Bjergaard, Ulrik
    Knop, Filip K.
    Vilsboll, Tina
    Andersen, Andreas
    FRONTIERS IN ENDOCRINOLOGY, 2024, 15
  • [25] Correlates of Continuous Glucose Monitoring Use Trajectories in Children and Adolescents with Type 1 Diabetes
    Miller, Victoria A.
    Xiao, Rui
    Willi, Steven M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (08) : 590 - 594
  • [26] Association between scanning frequency of flash glucose monitoring and continuous glucose monitoring-derived glycemic makers in children and adolescents with type 1 diabetes
    Suzuki, Junichi
    Urakami, Tatsuhiko
    Yoshida, Kei
    Kuwabara, Remi
    Mine, Yusuke
    Aoki, Masako
    Morioka, Ichiro
    PEDIATRICS INTERNATIONAL, 2021, 63 (02) : 154 - 159
  • [27] Salient Characteristics of Youth with Type 1 Diabetes Initiating Continuous Glucose Monitoring
    Telo, Gabriela H.
    Volkening, Lisa K.
    Butler, Deborah A.
    Laffel, Lori M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (06) : 373 - 378
  • [28] Continuous glucose monitoring reduces pubertal hyperglycemia of type 1 diabetes
    Nwosu, Benjamin Udoka
    Yeasmin, Shamima
    Ayyoub, Sanaa
    Rupendu, Shwetha
    Villalobos-Ortiz, Tony R.
    Jasmin, Gabrielle
    Parajuli, Sadichchha
    Zahedi, Bita
    Zitek-Morrison, Emily
    Alonso, Laura C.
    Barton, Bruce A.
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2020, 33 (07) : 865 - 872
  • [29] Youth with Type 1 Diabetes Had Improvement in Continuous Glucose Monitoring Metrics During the COVID-19 Pandemic
    Abdulhussein, Fatema S.
    Chesser, Hannah
    Boscardin, W. John
    Gitelman, Stephen E.
    Wong, Jenise C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (10) : 684 - 691
  • [30] Satisfaction with Continuous Glucose Monitoring in Pregnant Patients with Type 1 and Type 2 Diabetes
    Shrestha, Kevin S.
    Battarbee, Ashley N.
    AMERICAN JOURNAL OF PERINATOLOGY, 2024,