Influence of Test Protocol on Filtration Efficiency of Medical Face Mask Material

被引:0
|
作者
Joubert, Aurelie [1 ]
Bouhanguel, Ala [1 ]
Andres, Yves [1 ]
Le Coq, Laurence [1 ]
机构
[1] IMT Atlantique, CNRS, UMR 6144, GEPEA, 4 Rue Alfred Kastler,CS 20722, F-44307 Nantes, France
关键词
Test aerosols; MS2; virus; Electrostatic charges; Particle collection mechanisms; PARTICLE CHARGE-DISTRIBUTION; CAPTURE;
D O I
10.4209/aaqr.230180
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Medical face masks are an efficient protective barrier against the propagation of bacteria and viruses in societies. The current European standard focuses on the bacterial filtration efficiency of the filtering material for a mean particle size of 3.0 mu m in terms of droplets that are exhaled, but viruses that are inhaled can be transported by particles of sub-micron size. The filtration efficiency of medical face mask material was evaluated in a bench test from both unused charged and discharged masks. Several polydisperse test aerosols were used - DEHS, alumina, HOLI, NaCl, Staphylococcus epidermidis and Emesvirus zinderi (MS2) - produced by liquid atomization and/or powder dispersion, and sized by optical and aerodynamic counters or cascade impactors. The results have shown that the particle size distribution and charges for a given type of aerosol can differ depending on the generator used, in particular the wet or dry nature of generation. The results in the sub-micron size range for charged face mask material showed that the filtration efficiency of neutral aerosols was lower than that of charged aerosols due to the electrostatic forces, e.g., 92% versus 99% efficiency for DEHS and alumina respectively for a mean aerodynamic diameter of 0.6 mu m. With the discharged face mask material, the filtration efficiency was degraded in the sub-micron size range for all types of aerosol tested: e.g., 30% versus 65% efficiency for a mean optical diameter of 0.25 mu m respectively for DEHS and alumina. For particle sizes > 3 mu m, the results indicated that the nature of the aerosol has little influence because particle collection is dominated by impaction and interception mechanisms. The tests with MS2 virus demonstrated a good fit with NaCl filtration efficiency expressed in aerodynamic diameters over a range between 0.65 and > 7 mu m, for charged and discharged medical face mask materials.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Impact of medical face mask wear on bacterial filtration efficiency and breathability
    Armand, Quentin
    Whyte, Henrietta Essie
    Verhoeven, Paul
    Grattard, Florence
    Leclerc, Lara
    Curt, Nicolas
    Ragey, Sophie Perinel
    Pourchez, Jérémie
    Environmental Technology and Innovation, 2022, 28
  • [2] Impact of medical face mask wear on bacterial filtration efficiency and breathability
    Armand, Quentin
    Whyte, Henrietta Essie
    Verhoeven, Paul
    Grattard, Florence
    Leclerc, Lara
    Curt, Nicolas
    Ragey, Sophie Perinel
    Pourchez, Jeremie
    ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2022, 28
  • [3] The effects of face mask specifications on work of breathing and particle filtration efficiency
    Monjezi, Mojdeh
    Jamaati, Hamidreza
    MEDICAL ENGINEERING & PHYSICS, 2021, 98 : 36 - 43
  • [4] Mask Material Filtration Efficiency and Mask Fitting at the Crossroads: Implications during Pandemic Times
    Ardon-Dryer, Karin
    Warzywoda, Juliusz
    Tekin, Rumeysa
    Biros, Jnev
    Almodovar, Sharilyn
    Weeks, Brandon L.
    Hope-Weeks, Louisa J.
    Sacco, Albert, Jr.
    AEROSOL AND AIR QUALITY RESEARCH, 2021, 21 (07)
  • [5] Determining the filtration efficiency of half-face medical protection mask (N99) against viral aerosol
    Wen, ZhanBo
    Lu, JianChun
    Li, JinSong
    Li, Na
    Zhao, JianJun
    Wang, Jie
    Yu, Long
    Yang, WenHui
    AEROBIOLOGIA, 2010, 26 (03) : 245 - 251
  • [6] Determining the filtration efficiency of half-face medical protection mask (N99) against viral aerosol
    ZhanBo Wen
    JianChun Lu
    JinSong Li
    Na Li
    JianJun Zhao
    Jie Wang
    Long Yu
    WenHui Yang
    Aerobiologia, 2010, 26 : 245 - 251
  • [7] Acoustic Attenuation of COVID-19 Face Masks: Correlation to Fibrous Material Porosity, Mask Breathability and Bacterial Filtration Efficiency
    Martarelli, Milena
    Montalto, Luigi
    Chiariotti, Paolo
    Simoni, Serena
    Castellini, Paolo
    Battista, Gianmarco
    Paone, Nicola
    ACOUSTICS, 2022, 4 (01): : 123 - 138
  • [8] FILTRATION EFFICIENCY OF FACE MASKS. THE DEVELOPMENT OF A RAPID LATEX FILTRATION EFFICIENCY TEST METHOD FOR USE IN SIMULATING BACTERIAL FILTRATION EFFICIENCY.
    WADSWORTH, LARRY C.
    DAVIS, WAYNE T.
    1982, V 19 (N 5): : 393 - 395
  • [9] Evaluation of particle filtration efficiency of commercially available materials for homemade face mask usage
    Joo, Taekyu
    Takeuchi, Masayuki
    Liu, Fobang
    Rivera, Matthew P.
    Barr, Joy
    Blum, Emily S.
    Parker, Eric
    Tipton, John H.
    Varnedoe, Julia
    Dutta, Bahnisikha
    Lively, Ryan P.
    Ng, Nga Lee
    AEROSOL SCIENCE AND TECHNOLOGY, 2021, 55 (08) : 930 - 942
  • [10] Riboflavin based setup as an alternative method for a preliminary screening of face mask filtration efficiency
    Cavallo, Aida
    Al Kayal, Tamer
    Soldani, Giorgio
    Losi, Paola
    Tedeschi, Lorena
    SCIENTIFIC REPORTS, 2024, 14 (01)