Registration of preoperative temporal bone CT-scan to otoendoscopic video for augmented-reality based on convolutional neural networks

被引:1
作者
Taleb, Ali [1 ]
Leclerc, Sarah [1 ]
Hussein, Raabid [2 ]
Lalande, Alain [1 ,3 ]
Bozorg-Grayeli, Alexis [1 ,4 ]
机构
[1] Univ Burgundy Franche Comte, ICMUB Lab, UMR 6302, CNRS, F-21000 Dijon, France
[2] Oticon Med, F-06220 Vallauris, France
[3] Dijon Univ Hosp, Med Imaging Dept, F-21000 Dijon, France
[4] Dijon Univ Hosp, ENT Dept, F-21000 Dijon, France
关键词
Registration; Ear surgery; Endoscopic video; Augmented reality; TO-PATIENT REGISTRATION; OTOLOGIC SURGERY; IMAGE; HEAD; ENDOSCOPY; ACCURACY; SYSTEM;
D O I
10.1007/s00405-023-08403-0
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Purpose Patient-to-image registration is a preliminary step required in surgical navigation based on preoperative images. Human intervention and fiducial markers hamper this task as they are time-consuming and introduce potential errors. We aimed to develop a fully automatic 2D registration system for augmented reality in ear surgery. Methods CT-scans and corresponding oto-endoscopic videos were collected from 41 patients (58 ears) undergoing ear examination (vestibular schwannoma before surgery, profound hearing loss requiring cochlear implant, suspicion of perilymphatic fistula, contralateral ears in cases of unilateral chronic otitis media). Two to four images were selected from each case. For the training phase, data from patients (75% of the dataset) and 11 cadaveric specimens were used. Tympanic membranes and malleus handles were contoured on both video images and CT-scans by expert surgeons. The algorithm used a U-Net network for detecting the contours of the tympanic membrane and the malleus on both preoperative CT-scans and endoscopic video frames. Then, contours were processed and registered through an iterative closest point algorithm. Validation was performed on 4 cases and testing on 6 cases. Registration error was measured by overlaying both images and measuring the average and Hausdorff distances. Results The proposed registration method yielded a precision compatible with ear surgery with a 2D mean overlay error of 0.65 +/- 0.60 mm for the incus and 0.48 +/- 0.32 mm for the round window. The average Hausdorff distance for these 2 targets was 0.98 +/- 0.60 mm and 0.78 +/- 0.34 mm respectively. An outlier case with higher errors (2.3 mm and 1.5 mm average Hausdorff distance for incus and round window respectively) was observed in relation to a high discrepancy between the projection angle of the reconstructed CT-scan and the video image. The maximum duration for the overall process was 18 s. Conclusions A fully automatic 2D registration method based on a convolutional neural network and applied to ear surgery was developed. The method did not rely on any external fiducial markers nor human intervention for landmark recognition. The method was fast and its precision was compatible with ear surgery.
引用
收藏
页码:2921 / 2930
页数:10
相关论文
共 4 条
  • [1] Registration of preoperative temporal bone CT-scan to otoendoscopic video for augmented-reality based on convolutional neural networks
    Ali Taleb
    Sarah Leclerc
    Raabid Hussein
    Alain Lalande
    Alexis Bozorg-Grayeli
    European Archives of Oto-Rhino-Laryngology, 2024, 281 : 2921 - 2930
  • [2] Video-based augmented reality combining CT-scan and instrument position data to microscope view in middle ear surgery
    Hussain, Raabid
    Lalande, Alain
    Marroquin, Roberto
    Guigou, Caroline
    Grayeli, Alexis Bozorg
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [3] Image Recognition Model over Augmented Reality Based on Convolutional Neural Networks Through Color-Space Segmentation
    Ovidio Restrepo-Rodriguez, Andres
    Esteban Casas-Mateus, Daniel
    Alonso Gaona-Garcia, Paulo
    Enrique Montenegro-Marin, Carlos
    ADVANCES IN COMPUTER VISION, CVC, VOL 1, 2020, 943 : 326 - 338
  • [4] X-ray and CT-scan-based automated detection and classification of covid-19 using convolutional neural networks (CNN)
    Thakur, Samritika
    Kumar, Aman
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 69