Impact of coronary CT image quality on the accuracy of the FFRCT Planner

被引:7
作者
Andreini, Daniele [1 ,2 ]
Belmonte, Marta [3 ,4 ]
Penicka, Martin [3 ]
Van Hoe, Lieven [3 ]
Mileva, Niya [3 ,5 ]
Paolisso, Pasquale [3 ,4 ]
Nagumo, Sakura [3 ,6 ]
Norgaard, Bjarne L. [7 ]
Ko, Brian [8 ,9 ]
Otake, Hiromasa [10 ]
Koo, Bon-Kwon [11 ,12 ]
Jensen, Jesper Moller [7 ]
Mizukami, Takuya [3 ,6 ]
Munhoz, Daniel [3 ,4 ]
Updegrove, Adam [13 ]
Taylor, Charles [13 ]
Leipsic, Jonathon [14 ]
Sonck, Jeroen [3 ]
De Bruyne, Bernard [3 ,15 ]
Collet, Carlos [3 ]
机构
[1] Galeazzi St Ambrogio Hosp, Clin Cardiol & Cardiovasc Imaging Unit, IRCCS, Via Cristina Belgioioso 173, I-20157 Milan, Italy
[2] Univ Milan, Dept Biomed & Clin Sci, Milan, Italy
[3] OLV Clin, Cardiovasc Ctr Aalst, Aalst, Belgium
[4] Univ Federico II, Dept Adv Biomed Sci, Naples, Italy
[5] Med Univ Sofia, Sofia, Bulgaria
[6] Showa Univ, Dept Cardiol, Fujigaoka Hosp, Yokohama, Kanagawa, Japan
[7] Aarhus Univ Hosp, Dept Cardiol, Aarhus, Denmark
[8] Monash Univ, Monash Cardiovasc Res Ctr, Clayton, Vic, Australia
[9] Monash Hlth, Monash Heart, Clayton, Vic, Australia
[10] Kobe Univ, Dept Internal Med, Div Cardiovasc Med, Grad Sch Med, Kobe, Hyogo, Japan
[11] Seoul Natl Univ Hosp, Dept Internal Med, Seoul, South Korea
[12] Seoul Natl Univ Hosp, Cardiovasc Ctr, Seoul, South Korea
[13] HeartFlow Inc, Redwood City, CA USA
[14] Univ British Columbia, Dept Med & Radiol, Vancouver, BC, Canada
[15] Lausanne Univ Hosp, Dept Cardiol, Lausanne, Switzerland
关键词
FFRCT; Coronary CT angiography; Percutaneous Coronary Intervention Planner; Image quality; Artifacts; FRACTIONAL FLOW RESERVE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; DIAGNOSTIC-ACCURACY; HEART-RATE; PERFORMANCE;
D O I
10.1007/s00330-023-10228-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To assess the accuracy of a virtual stenting tool based on coronary CT angiography (CCTA) and fractional flow reserve (FFR) derived from CCTA (FFRCT Planner) across different levels of image quality. Materials and methods Prospective, multicenter, single-arm study of patients with chronic coronary syndromes and lesions with FFR <= 0.80. All patients underwent CCTA performed with recent-generation scanners. CCTA image quality was adjudicated using the four-point Likert scale at a per-vessel level by an independent committee blinded to the FFRCT Planner. Patient- and technical-related factors that could affect the FFRCT Planner accuracy were evaluated. The FFRCT Planner was applied mirroring percutaneous coronary intervention (PCI) to determine the agreement with invasively measured post-PCI FFR. Results Overall, 120 patients (123 vessels) were included. Invasive post-PCI FFR was 0.880.06 and Planner FFRCT was 0.860.06 (mean difference 0.02 FFR units, the lower limit of agreement (LLA)-0.12, upper limit of agreement (ULA) 0.15). CCTA image quality was assessed as excellent (Likert score 4) in 48.3%, good (Likert score 3) in 45%, and sufficient (Likert score 2) in 6.7% of patients. The FFRCT Planner was accurate across different levels of image quality with a mean difference between FFRCT Planner and invasive post-PCI FFR of 0.020.07 in Likert score 4, 0.020.07 in Likert score 3 and 0.030.08 in Likert score 2, p=0.695. Nitrate dose >= 0.8mg was the only independent factor associated with the accuracy of the FFRCT Planner (95%CI-0.06 to-0.001, p=0.040). Conclusion The FFRCT Planner was accurate in predicting post-PCI FFR independent of CCTA image quality.
引用
收藏
页码:2677 / 2688
页数:12
相关论文
共 27 条
  • [1] SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: A report of the society of Cardiovascular Computed Tomography Guidelines Committee Endorsed by the North American Society for Cardiovascular Imaging (NASCI)
    Abbara, Suhny
    Blanke, Philipp
    Maroules, Christopher D.
    Cheezum, Michael
    Choi, Andrew D.
    Han, B. Kelly
    Marwan, Mohamed
    Naoum, Chris
    Norgaard, Bjarne L.
    Rubinshtein, Ronen
    Schoenhagen, Paul
    Villines, Todd
    Leipsic, Jonathon
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (06) : 435 - 449
  • [2] Image quality and radiation dose of coronary CT angiography performed with whole-heart coverage CT scanner with intra-cycle motion correction algorithm in patients with atrial fibrillation
    Andreini, Daniele
    Pontone, Gianluca
    Mushtaq, Saima
    Mancini, Maria Elisabetta
    Conte, Edoardo
    Guglielmo, Marco
    Volpato, Valentina
    Annoni, Andrea
    Baggiano, Andrea
    Formenti, Alberto
    Ditali, Valentina
    Perchinunno, Marco
    Fiorentini, Cesare
    Bartorelli, Antonio L.
    Pepi, Mauro
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (04) : 1383 - 1392
  • [3] Atrial Fibrillation: Diagnostic Accuracy of Coronary CT Angiography Performed with a Whole-Heart 230-μm Spatial Resolution CT Scanner
    Andreini, Daniele
    Pontone, Gianluca
    Mushtaq, Saima
    Conte, Edoardo
    Perchinunno, Marco
    Guglielmo, Marco
    Volpato, Valentina
    Annoni, Andrea
    Baggiano, Andrea
    Formenti, Alberto
    Mancini, Maria Elisabetta
    Beltrama, Virginia
    Ditali, Valentina
    Campari, Alessandro
    Fiorentini, Cesare
    Bartorelli, Antonio L.
    Pepi, Mauro
    [J]. RADIOLOGY, 2017, 284 (03) : 676 - 684
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] Effects of nitroglycerin on the diagnostic accuracy of electrocardiogram-gated coronary computed tomography angiography
    Chun, Eun Ju
    Lee, Whal
    Choi, Young Hoon
    Koo, Bon-Kwon
    Choi, Sang Il
    Jae, Hwan Jun
    Kim, Hyo-Cheol
    So, Young Ho
    Chung, Jin Wook
    Park, Jae Hyung
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (01) : 86 - 92
  • [6] Patient Characteristics as Predictors of Image Quality and Diagnostic Accuracy of MDCT Compared With Conventional Coronary Angiography for Detecting Coronary Artery Stenoses: CORE-64 Multicenter International Trial
    Dewey, Marc
    Vavere, Andrea L.
    Arbab-Zadeh, Armin
    Miller, Julie M.
    Sara, Leonardo
    Cox, Christopher
    Gottlieb, Ilan
    Yoshioka, Kunihiro
    Paul, Narinder
    Hoe, John
    de Roos, Albert
    Lardo, Albert C.
    Lima, Joao A.
    Clouse, Melvin E.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) : 93 - 102
  • [7] Real-world clinical utility and impact on clinical decision-making of coronary computed tomography angiography-derived fractional flow reserve: lessons from the ADVANCE Registry
    Fairbairn, Timothy A.
    Nieman, Koen
    Akasaka, Takashi
    Norgaard, Bjarne L.
    Berman, Daniel S.
    Raff, Gilbert
    Hurwitz-Koweek, Lynne M.
    Pontone, Gianluca
    Kawasaki, Tomohiro
    Sand, Niels Peter
    Jensen, Jesper M.
    Amano, Tetsuya
    Poon, Michael
    Ovrehus, Kristian
    Sonck, Jeroen
    Rabbat, Mark
    Mullen, Sarah
    De Bruyne, Bernard
    Rogers, Campbell
    Matsuo, Hitoshi
    Bax, Jeroen J.
    Leipsic, Jonathon
    Patel, Manesh R.
    [J]. EUROPEAN HEART JOURNAL, 2018, 39 (41) : 3701 - 3711
  • [8] CORONARY ARTERIAL RESPONSES TO GRADED DOSES OF NITROGLYCERIN
    FELDMAN, RL
    PEPINE, CJ
    CURRY, RC
    CONTI, CR
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1979, 43 (01) : 91 - 97
  • [9] Association of Improvement in Fractional Flow Reserve With Outcomes, Including Symptomatic Relief, After Percutaneous Coronary Intervention
    Fournier, Stephane
    Ciccarelli, Giovanni
    Toth, Gabor G.
    Milkas, Anastasios
    Xaplanteris, Panagiotis
    Tonino, Pim A. L.
    Fearon, William F.
    Pijls, Nico H. J.
    Barbato, Emanuele
    De Bruyne, Bernard
    [J]. JAMA CARDIOLOGY, 2019, 4 (04) : 370 - 374
  • [10] Impact of sublingual nitroglycerin dosage on FFRCT assessment and coronary luminal volume-to-myocardial mass ratio
    Holmes, Kenneth R.
    Fonte, Tim A.
    Weir-McCall, Jonathan
    Anastasius, Malcolm
    Blanke, Philipp
    Payne, Geoffrey W.
    Ellis, Jen
    Murphy, Darra T.
    Taylor, Charles
    Leipsic, Jonathon A.
    Sellers, Stephanie L.