Estimating Changes in Glomerular Filtration Rate With Fluorescein Isothiocyanate-Sinistrin During Renal Replacement Therapy

被引:1
作者
Chan, Goldia [1 ]
Pino, Christopher J. [2 ,3 ]
Johnston, Kimberly A. [2 ,3 ]
Humes, H. David [2 ,3 ]
机构
[1] Univ Michigan, Dept Vet Med, Ann Arbor, MI 48109 USA
[2] Innovat BioTherapies Inc, Ann Arbor, MI USA
[3] Univ Michigan, Dept Internal Med Nephrol, 4520 MSRB 1,SPC 5651,1150 W Med Ctr Dr, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
renal function; kidney injury; extracorporeal therapy; ACUTE KIDNEY INJURY; TRANSCUTANEOUS MEASUREMENT; AKI;
D O I
10.1097/MAT.0000000000001947
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Excreted exclusively by the kidneys, fluorescein isothiocyanate (FITC)-sinistrin can be used to measure glomerular filtration rate (GFR) and is detectable transdermally. Determination of changes in native kidney GFR (NK-GFR) in patients with acute kidney injury, particularly during continuous renal replacement therapy, improves clinical decision-making capability. To test feasibility of measuring changes in NK-GFR during CRRT with FITC-sinistrin, in vitro circuits (n = 2) were utilized to simultaneously clear FITC-sinistrin by removal of ultrafiltrate at varying rates, simulating kidney function, and by dialysis at a constant rate. Clearance calculated by fluorescence-measuring devices on the circuit showed good agreement with clearance calculated from assay of fluid samples (R-2 = 0.949). In vivo feasibility was studied by dialyzing anesthetized pigs (n = 3) and measuring FITC-sinistrin clearance during progression from normal, to unilaterally, then bilaterally nephrectomized. FITC-sinistrin clearance was reduced in vitro, when ultrafiltrate was decreased or with successive nephrectomies in vivo. Transdermal readers showed 100% sensitivity in detecting a decrease in NK-GFR in pigs with a bias of 6.5 & PLUSMN; 13.4% between transdermal-derived GFR (tGFR) and plasma-measured methods determining proportional changes in clearance. Clearance of FITC-sinistrin by dialysis remained consistent. In patients receiving a constant dialysis prescription, transdermal measurement of FITC-sinistrin can detect relative changes in NK-GFR.
引用
收藏
页码:810 / 815
页数:6
相关论文
共 23 条
[21]   Challenges in Measuring Glomerular Filtration Rate: A Clinical Laboratory Perspective [J].
Seegmiller, Jesse C. ;
Eckfeldt, John H. ;
Lieske, John C. .
ADVANCES IN CHRONIC KIDNEY DISEASE, 2018, 25 (01) :84-92
[22]   A Pilot Study to Assess the Feasibility of Transcutaneous Glomerular Filtration Rate Measurement Using Fluorescence-Labelled Sinistrin in Dogs and Cats [J].
Steinbach, Sarah ;
Krolop, Nora ;
Strommer, Sellyn ;
Herrera-Perez, Zeneida ;
Geraci, Stefania ;
Friedemann, Jochen ;
Gretz, Norbert ;
Neiger, Reto .
PLOS ONE, 2014, 9 (11)
[23]   A portable fiberoptic ratiometric fluorescence analyzer provides rapid point-of-care determination of glomerular filtration rate in large animals [J].
Wang, Exing ;
Meier, Daniel J. ;
Sandoval, Ruben M. ;
Von Hendy-Willson, Vanessa E. ;
Pressler, Barrak M. ;
Bunch, Robert M. ;
Alloosh, Mouhamad ;
Sturek, Michael S. ;
Schwartz, George J. ;
Molitoris, Bruce A. .
KIDNEY INTERNATIONAL, 2012, 81 (01) :112-117