Estimating Changes in Glomerular Filtration Rate With Fluorescein Isothiocyanate-Sinistrin During Renal Replacement Therapy

被引:1
作者
Chan, Goldia [1 ]
Pino, Christopher J. [2 ,3 ]
Johnston, Kimberly A. [2 ,3 ]
Humes, H. David [2 ,3 ]
机构
[1] Univ Michigan, Dept Vet Med, Ann Arbor, MI 48109 USA
[2] Innovat BioTherapies Inc, Ann Arbor, MI USA
[3] Univ Michigan, Dept Internal Med Nephrol, 4520 MSRB 1,SPC 5651,1150 W Med Ctr Dr, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
renal function; kidney injury; extracorporeal therapy; ACUTE KIDNEY INJURY; TRANSCUTANEOUS MEASUREMENT; AKI;
D O I
10.1097/MAT.0000000000001947
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Excreted exclusively by the kidneys, fluorescein isothiocyanate (FITC)-sinistrin can be used to measure glomerular filtration rate (GFR) and is detectable transdermally. Determination of changes in native kidney GFR (NK-GFR) in patients with acute kidney injury, particularly during continuous renal replacement therapy, improves clinical decision-making capability. To test feasibility of measuring changes in NK-GFR during CRRT with FITC-sinistrin, in vitro circuits (n = 2) were utilized to simultaneously clear FITC-sinistrin by removal of ultrafiltrate at varying rates, simulating kidney function, and by dialysis at a constant rate. Clearance calculated by fluorescence-measuring devices on the circuit showed good agreement with clearance calculated from assay of fluid samples (R-2 = 0.949). In vivo feasibility was studied by dialyzing anesthetized pigs (n = 3) and measuring FITC-sinistrin clearance during progression from normal, to unilaterally, then bilaterally nephrectomized. FITC-sinistrin clearance was reduced in vitro, when ultrafiltrate was decreased or with successive nephrectomies in vivo. Transdermal readers showed 100% sensitivity in detecting a decrease in NK-GFR in pigs with a bias of 6.5 & PLUSMN; 13.4% between transdermal-derived GFR (tGFR) and plasma-measured methods determining proportional changes in clearance. Clearance of FITC-sinistrin by dialysis remained consistent. In patients receiving a constant dialysis prescription, transdermal measurement of FITC-sinistrin can detect relative changes in NK-GFR.
引用
收藏
页码:810 / 815
页数:6
相关论文
共 23 条
[1]  
Fanous MS., 2022, J VIS EXP, V187
[2]   Understanding Bland Altman analysis [J].
Giavarina, Davide .
BIOCHEMIA MEDICA, 2015, 25 (02) :141-151
[3]  
HANNON JP, 1990, LAB ANIM SCI, V40, P293
[4]   Global epidemiology and outcomes of acute kidney injury [J].
Hoste, Eric A. J. ;
Kellum, John A. ;
Selby, Nicholas M. ;
Zarbock, Alexander ;
Palevsky, Paul M. ;
Bagshaw, Sean M. ;
Goldstein, Stuart L. ;
Cerda, Jorge ;
Chawla, Lakhmir S. .
NATURE REVIEWS NEPHROLOGY, 2018, 14 (10) :607-625
[5]   Epidemiology of acute kidney injury in critically ill patients: the multinational AKI-EPI study [J].
Hoste, Eric A. J. ;
Bagshaw, Sean M. ;
Bellomo, Rinaldo ;
Cely, Cynthia M. ;
Colman, Roos ;
Cruz, Dinna N. ;
Edipidis, Kyriakos ;
Forni, Lui G. ;
Gomersall, Charles D. ;
Govil, Deepak ;
Honore, Patrick M. ;
Joannes-Boyau, Olivier ;
Joannidis, Michael ;
Korhonen, Anna-Maija ;
Lavrentieva, Athina ;
Mehta, Ravindra L. ;
Palevsky, Paul ;
Roessler, Eric ;
Ronco, Claudio ;
Uchino, Shigehiko ;
Vazquez, Jorge A. ;
Vidal Andrade, Erick ;
Webb, Steve ;
Kellum, John A. .
INTENSIVE CARE MEDICINE, 2015, 41 (08) :1411-1423
[6]   Why are patients still getting and dying from acute kidney injury? [J].
Kellum, John A. .
CURRENT OPINION IN CRITICAL CARE, 2016, 22 (06) :513-519
[7]   Diagnostic Criteria for Acute Kidney Injury: Present and Future [J].
Kellum, John A. .
CRITICAL CARE CLINICS, 2015, 31 (04) :621-+
[8]   Classifying AKI by Urine Output versus Serum Creatinine Level [J].
Kellum, John A. ;
Sileanu, Florentina E. ;
Murugan, Raghavan ;
Lucko, Nicole ;
Shaw, Andrew D. ;
Clermont, Gilles .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2015, 26 (09) :2231-2238
[9]   Measured and estimated glomerular filtration rate: current status and future directions [J].
Levey, Andrew S. ;
Coresh, Josef ;
Tighiouart, Hocine ;
Greene, Tom ;
Inker, Lesley A. .
NATURE REVIEWS NEPHROLOGY, 2020, 16 (01) :51-64
[10]   A Simple Method to Measure Renal Function in Swine by the Plasma Clearance of Iohexol [J].
Luis-Lima, Sergio ;
Garcia-Contreras, Consolacion ;
Vazquez-Gomez, Marta ;
Astiz, Susana ;
Carrara, Fabiola ;
Gaspari, Flavio ;
Negrin-Mena, Natalia ;
Jimenez-Sosa, Alejandro ;
Jimenez-Hernandez, Hugo ;
Gonzalez-Bulnes, Antonio ;
Porrini, Esteban .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2018, 19 (01)