Concordance study on Y-STRs typing between SeqStudio™ genetic analyzer for HID and MiSeq™ FGx forensic genomics system

被引:1
作者
Giulia, Soldati [1 ]
Stefania, Turrina [1 ]
Mirko, Treccani [2 ]
Chiara, Saccardo [1 ]
Francesco, Ausania [1 ]
Domenico, De Leo [1 ]
机构
[1] Univ Verona, Dept Diagnost & Publ Hlth, Sect Forens Med, Forens Genet Lab, Verona, Italy
[2] Univ Verona, Dept Neurosci Biomed & Movement Sci, GM Lab, Verona, Italy
关键词
MiSeq (TM) FGx Forensic Genomics System; SeqStudio (TM) Genetic Analyzer for HID; DNA typing; Y-chromosome short Tandem repeats (Y-STRs); Forensic validation and concordance studies; SEQUENCE VARIATION; FORENSEQ(TM) SYSTEM; LOCI; VALIDATION; KIT; ASSAY;
D O I
10.1007/s11033-023-08808-4
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
BackgroundMassively Parallel Sequencing (MPS) allowed an increased number of information to be retrieved from short tandem repeat (STR) analysis, expanding them not only to the size, as already performed in Capillary Electrophoresis (CE), but also to the sequence. MPS requires constant development and validation of the analytical parameters to ensure that the genotyping results of STRs correspond to those obtained by CE. Given the increased frequency of usage of Y-STRs as supplementary markers to the autosomal STRs analysis, it is urgent to validate the concordance of the typing results between CE and MPS analyses.Methods and resultsDNA extracted from 125 saliva samples of unrelated males was genotyped using Yfiler (TM) Plus PCR Amplification Kit and ForenSeq (TM) DNA Signature Prep Kit, which were analyzed by SeqStudio (TM) Genetic Analyzer for HID and MiSeq (TM) FGx Forensic Genomics System, respectively. For each shared Y-STR, allele designation, number of length- and sequence-based alleles per locus, stutter percentage, and the intra-locus balance of multicopy Y-STRs were screened.ConclusionsAlthough the number of forensic genetics laboratories that are applying the MPS technique in routine analysis is small and does not allow a global assessment of MPS limitations, this comparative study highlights the ability of MPS to produce reliable profiles despite the generation of large amounts of raw data.
引用
收藏
页码:9779 / 9789
页数:11
相关论文
共 9 条
  • [1] Concordance study on Y-STRs typing between SeqStudio™ genetic analyzer for HID and MiSeq™ FGx forensic genomics system
    Giulia Soldati
    Stefania Turrina
    Mirko Treccani
    Chiara Saccardo
    Francesco Ausania
    Domenico De Leo
    Molecular Biology Reports, 2023, 50 : 9779 - 9789
  • [2] Forensic genetic study of 29 Y-STRs in Korean population
    Jung, Ju Yeon
    Park, Ji-Hye
    Oh, Yu-Li
    Kwon, Han-Sol
    Park, Hyun-Chul
    Park, Kyung-Hwa
    Kim, Eun Hye
    Lee, Dong-Sub
    Lim, Si-Keun
    LEGAL MEDICINE, 2016, 23 : 17 - 20
  • [3] High-resolution genotyping of 58 STRs in 635 Northern Han Chinese with MiSeq FGx ® Forensic Genomics System
    Guo, Fei
    Liu, Ze
    Long, Guannan
    Zhang, Biao
    Dong, Xinyu
    Liu, Dahua
    Yu, Shaobo
    FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2023, 65
  • [4] Development of a new 26plex Y-STRs typing system for forensic application
    Zhang, Suhua
    Tian, Huaizhou
    Wang, Zheng
    Zhao, Shumin
    Hu, Zhen
    Li, Chengtao
    Ji, Chaoneng
    FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2014, 13 : 112 - 120
  • [5] Development and validation of a multiplex typing system with 32 Y-STRs for forensic application
    Xiong, Chen
    Yang, Chengliang
    Wu, Weibin
    Zeng, Ying
    Lin, Tianchun
    Chen, Ling
    Liu, Hong
    Liu, Changhui
    Du, Weian
    Wang, Mengge
    Sun, Hongyu
    Liu, Chao
    FORENSIC SCIENCE INTERNATIONAL, 2022, 339
  • [6] Developmental validation of a novel 8-dye fluorescent typing system with 59 Y-STRs and 3 Y-indels for forensic applications
    Liu, Yanan
    Liu, Tiezhu
    Chen, Ronghua
    Hao, Sijing
    Li, Shilin
    Tang, Zhen
    Xia, Mingying
    Li, Xiuli
    Cheng, Cheng
    Li, Qinli
    Li, Hui
    ELECTROPHORESIS, 2024, 45 (9-10) : 829 - 842
  • [7] Internal validation study of a newly developed 24-plex Y-STRs genotyping system for forensic application
    Meng, Haotian
    Guo, Yuxin
    Jin, Xiaoye
    Chen, Chong
    Cui, Wei
    Shi, Jianfeng
    Wang, Xinxin
    Liu, Ruolin
    Zhu, Bofeng
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2019, 133 (03) : 733 - 743
  • [8] Internal validation study of a newly developed 24-plex Y-STRs genotyping system for forensic application
    Haotian Meng
    Yuxin Guo
    Xiaoye Jin
    Chong Chen
    Wei Cui
    Jianfeng Shi
    Xinxin Wang
    Ruolin Liu
    Bofeng Zhu
    International Journal of Legal Medicine, 2019, 133 : 733 - 743
  • [9] RETRACTED: Forensic characteristics and genetic affinity analyses of Xinjiang Mongolian group using a novel six fluorescent dye-labeled typing system including 41 Y-STRs and 3 Y-InDels (Retracted Article)
    Liu, Yanfang
    Yu, Tingting
    Mei, Shuyan
    Jin, Xiaoye
    Lan, Qiong
    Zhou, Yongsong
    Fang, Yating
    Xie, Tong
    Huang, Jiabin
    Zhu, Bofeng
    MOLECULAR GENETICS & GENOMIC MEDICINE, 2020, 8 (02):