Therapeutic effect of a new implantation method of rotationally asymmetric multifocal intraocular lenses on visual quality

被引:1
作者
Wu, Xian [1 ,2 ]
Liu, Xiaomin [1 ,2 ]
Li, Dongfang [1 ,2 ]
Wang, Xiaoyun [1 ,2 ]
Huang, Yusen [1 ,2 ]
机构
[1] Shandong First Med Univ, Qingdao Eye Hosp, Qingdao, Peoples R China
[2] Shandong First Med Univ, Shandong Eye Inst, State Key Lab Cultivat Base, Shandong Prov Key Lab Ophthalmol, Qingdao, Peoples R China
基金
中国国家自然科学基金;
关键词
Angle kappa; Cataract surgery; Rotationally asymmetric multifocal intraocular lens; Visual quality; OPTICAL-PERFORMANCE; IOL; DECENTRATION; OUTCOMES; TILT;
D O I
10.1007/s10792-023-02862-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo assess the visual quality after implantation of a rotationally asymmetric multifocal intraocular lens (IOL) using a new method according to the angle kappa.SettingQingdao Eye Hospital, Qingdao, China.DesignProspective case series.MethodsPatients with the implantation of SBL-3 IOLs for age-related cataract from September to December 2019 had the distance-horizontal zone of the IOL placed at the center of the optic axis using the Callisto Eye System. Postoperative visual acuities and defocus curves were recorded. Modulation transfer function cutoff frequency, Strehl ratio, and objective scatter index were measured using the Optical Quality Analysis System. The decentration and tilt of IOLs were analyzed by iTrace aberrometry and anterior segment optical coherence tomography. A questionnaire of patient satisfaction was also collected.ResultsThirty patients (60 eyes) were involved, with a balanced sex ratio. Their average age was 56.04 & PLUSMN; 10.83 years. The average angle kappa distance was 0.23 & PLUSMN; 0.121 mm. At 3 months after surgery, the mean uncorrected and corrected distance visual acuities were 0.01 & PLUSMN; 0.07 logMAR and 0.01 & PLUSMN; 0.06 logMAR. The uncorrected intermediate and near visual acuities were 0.09 & PLUSMN; 0.11 logMAR and 0.09 & PLUSMN; 0.11 logMAR. The mean horizontal and vertical tilts of IOLs were 0.67 & PLUSMN; 0.52 degrees and 0.47 & PLUSMN; 0.32 degrees. The mean decentration of IOLs was 0.17 & PLUSMN; 0.08 mm. Most patients were satisfied with their distance, intermediate, and near vision. There was mild glare in 58.3% of the eyes.ConclusionsLocating the center of the optic axis in the distance-horizontal zone during the implantation of SBL-3 IOLs could provide satisfactory visual acuity and quality.
引用
收藏
页码:4621 / 4629
页数:9
相关论文
共 23 条
  • [11] Effects of decentration and tilt at different orientations on the optical performance of a rotationally asymmetric multifocal intraocular lens
    Liu, Xiaomin
    Xie, Lixin
    Huang, Yusen
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (04) : 507 - 514
  • [12] Comparison of the Visual Performance After Implantation of Bifocal and Trifocal Intraocular Lenses Having an Identical Platform
    Liu, Xiaomin
    Xie, Lixin
    Huang, Yusen
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (04) : 273 - +
  • [13] Influence of angle kappa-customized implantation of rotationally asymmetric multifocal intraocular lens on visual quality and patient satisfaction
    Liu, Yiyun
    Gao, Yufei
    Liu, Rongjun
    Hu, Chenxi
    Ma, Baikai
    Miao, Jinhong
    Luo, Jinhua
    Qi, Hong
    [J]. ACTA OPHTHALMOLOGICA, 2020, 98 (06) : E734 - E742
  • [14] Capsular contraction syndrome following insertion of hydrophilic acrylic lens
    Malik A.
    Gupta N.
    Sood S.
    [J]. International Ophthalmology, 2011, 31 (2) : 121 - 123
  • [15] Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses
    McNeely, Richard N.
    Pazo, Eric
    Spence, Andrew
    Richoz, Olivier
    Nesbit, M. Andrew
    Moore, Tara C. B.
    Moore, Jonathan E.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (08) : 1020 - 1026
  • [16] Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment
    Pazo, Eric E.
    McNeely, Richard N.
    Richoz, Olivier
    Nesbit, M. Andrew
    Moore, Tara C. B.
    Moore, Jonathan E.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (11) : 1420 - 1429
  • [17] Optimized Visual Outcome After Asymmetrical Multifocal IOL Rotation
    Pazo, Eric E.
    Richoz, Olivier
    McNeely, Richard
    Millar, Zachary A.
    Moore, Tara C. B.
    Moore, Jonathan E.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (07) : 494 - +
  • [18] Role of angle κ in visual quality in patients with a trifocal diffractive intraocular lens
    Qi, Yingying
    Lin, Jing
    Leng, Lin
    Zhao, Guiqiu
    Wang, Qing
    Li, Cui
    Hu, Liting
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (08) : 949 - 954
  • [19] Influence of Near-Segment Positioning in a Rotationally Asymmetric Multifocal Intraocular Lens
    Song, In Seok
    Yoon, Sam Young
    Kim, Jae Yong
    Kim, Myoung Joon
    Tchah, Hungwon
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (04) : 238 - +
  • [20] Comparison of Long-term Visual Outcome and IOL Position With a Single-optic Accommodating IOL After 5.5-or 6.0-mm Femtosecond Laser Capsulotomy
    Szigeti, Andrea
    Kranitz, Kinga
    Takacs, Agnes I.
    Mihaltz, Kata
    Knorz, Michael C.
    Nagy, Zoltan Z.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (09) : 609 - 613