Therapeutic effect of a new implantation method of rotationally asymmetric multifocal intraocular lenses on visual quality

被引:1
作者
Wu, Xian [1 ,2 ]
Liu, Xiaomin [1 ,2 ]
Li, Dongfang [1 ,2 ]
Wang, Xiaoyun [1 ,2 ]
Huang, Yusen [1 ,2 ]
机构
[1] Shandong First Med Univ, Qingdao Eye Hosp, Qingdao, Peoples R China
[2] Shandong First Med Univ, Shandong Eye Inst, State Key Lab Cultivat Base, Shandong Prov Key Lab Ophthalmol, Qingdao, Peoples R China
基金
中国国家自然科学基金;
关键词
Angle kappa; Cataract surgery; Rotationally asymmetric multifocal intraocular lens; Visual quality; OPTICAL-PERFORMANCE; IOL; DECENTRATION; OUTCOMES; TILT;
D O I
10.1007/s10792-023-02862-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo assess the visual quality after implantation of a rotationally asymmetric multifocal intraocular lens (IOL) using a new method according to the angle kappa.SettingQingdao Eye Hospital, Qingdao, China.DesignProspective case series.MethodsPatients with the implantation of SBL-3 IOLs for age-related cataract from September to December 2019 had the distance-horizontal zone of the IOL placed at the center of the optic axis using the Callisto Eye System. Postoperative visual acuities and defocus curves were recorded. Modulation transfer function cutoff frequency, Strehl ratio, and objective scatter index were measured using the Optical Quality Analysis System. The decentration and tilt of IOLs were analyzed by iTrace aberrometry and anterior segment optical coherence tomography. A questionnaire of patient satisfaction was also collected.ResultsThirty patients (60 eyes) were involved, with a balanced sex ratio. Their average age was 56.04 & PLUSMN; 10.83 years. The average angle kappa distance was 0.23 & PLUSMN; 0.121 mm. At 3 months after surgery, the mean uncorrected and corrected distance visual acuities were 0.01 & PLUSMN; 0.07 logMAR and 0.01 & PLUSMN; 0.06 logMAR. The uncorrected intermediate and near visual acuities were 0.09 & PLUSMN; 0.11 logMAR and 0.09 & PLUSMN; 0.11 logMAR. The mean horizontal and vertical tilts of IOLs were 0.67 & PLUSMN; 0.52 degrees and 0.47 & PLUSMN; 0.32 degrees. The mean decentration of IOLs was 0.17 & PLUSMN; 0.08 mm. Most patients were satisfied with their distance, intermediate, and near vision. There was mild glare in 58.3% of the eyes.ConclusionsLocating the center of the optic axis in the distance-horizontal zone during the implantation of SBL-3 IOLs could provide satisfactory visual acuity and quality.
引用
收藏
页码:4621 / 4629
页数:9
相关论文
共 23 条
  • [1] Clinical and Optical Intraocular Performance of Rotationally Asymmetric Multifocal IOL Plate-Haptic Design Versus C-Loop Haptic Design
    Alio, Jorge L.
    Plaza-Puche, Ana B.
    Javaloy, Jaime
    Jose Ayala, Maria
    Vega-Estrada, Alfredo
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (04) : 252 - 259
  • [2] Rotationally Asymmetric Multifocal IOL Implantation With and Without Capsular Tension Ring: Refractive and Visual Outcomes and Intraocular Optical Performance
    Alio, Jorge L.
    Plaza-Puche, Ana B.
    Pinero, David P.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (04) : 253 - 258
  • [3] Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens
    Alio, Jorge L.
    Pinero, David P.
    Plaza-Puche, Ana B.
    Joanna Rodriguez, Maria
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) : 241 - 250
  • [4] Effect of number and position of intraocular lens haptics on anterior capsule contraction: a randomized, prospective trial
    Choi, Mihyun
    Lazo, Marjorie Z.
    Kang, Minji
    Lee, Jeehye
    Joo, Choun-Ki
    [J]. BMC OPHTHALMOLOGY, 2018, 18
  • [5] Influence of angle kappa and angle alpha on visual quality after implantation of multifocal intraocular lenses
    Fu, Yana
    Kou, Jiaojiao
    Chen, Dongjie
    Wang, Dandan
    Zhao, Yinyin
    Hu, Man
    Lin, Xiaolei
    Dai, Qi
    Li, Junhua
    Zhao, Yun-e
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (09) : 1258 - 1264
  • [6] Neodymium:YAG laser rates after bilateral implantation of hydrophobic or hydrophilic multifocal intraocular lenses: Twenty-four month retrospective comparative study
    Gauthier, Laurent
    Lafuma, Antoine
    Laurendeau, Caroline
    Berdeaux, Gilles
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (07) : 1195 - 1200
  • [7] The Balanced Two-String Technique for Sulcus Intraocular Lens Implantation in the Absence of Capsular Support
    Ibrahim, Hesham A.
    Sabry, Heba Nabil
    [J]. JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [8] Capsular opening contraction after continuous curvilinear capsulorhexis and intraocular lens implantation
    Joo, CK
    Shin, JA
    Kim, JH
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (05) : 585 - 590
  • [9] Intraocular Lens Tilt and Decentration Measured By Scheimpflug Camera Following Manual or Femtosecond Laser-created Continuous Circular Capsulotomy
    Kranitz, Kinga
    Mihaltz, Kata
    Sandor, Gabor L.
    Takacs, Agnes
    Knorz, Michael C.
    Nagy, Zoltan Z.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (04) : 259 - 263
  • [10] Evaluation of Intraocular Lens Tilt With Anterior Segment Optical Coherence Tomography
    Kumar, Dhivya Ashok
    Agarwal, Amar
    Prakash, Gaurav
    Jacob, Soosan
    Saravanan, Yoga
    Agarwal, Athiya
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (03) : 406 - 412