Determination of protamine and heparin based on their effects on a glucose oxidase enzymatic reaction

被引:0
作者
Uematsu, Kohei [1 ]
Ueno, Takaaki [1 ]
Katano, Hajime [1 ]
机构
[1] Fukui Prefectural Univ, Dept Biosci & Biotechnol, Eiheiji, Fukui 9101195, Japan
关键词
Determination; Protamine; Heparin; Glucose oxidase; Polyion complex; POLY-L-LYSINE; COLORIMETRIC SENSOR; FLUORESCENT-PROBE; GOLD NANORODS; AGGREGATION; STREPTOTHRICIN; NANOPARTICLES; SEPARATION; EFFICIENT; DRUGS;
D O I
10.1007/s44211-023-00373-x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a sensitive method for determining protamine and heparin by utilizing a glucose oxidase enzymatic reaction. Polycationic protamine significantly promoted the enzymatic reaction rate with [Fe(CN)(6)](3-), so that the increase could be used to determine protamine. The promotion effect was stoichiometrically decreased by the addition of polyanionic heparin through the polyion complex formation with protamine, so that the enzymatic reaction also allowed for the determination of heparin. We thus applied the proposed method to blood plasma containing heparin and found that heparin did not stoichiometrically form a polyion complex with protamine, likely due to strong interactions between heparin and some components of the plasma. The proposed method allowed for the detection of free protamine (and/ or weakly binding protamine with heparin) existing in the condition that protamine did not neutralize all of the heparin in the plasma. The method also permitted for the estimation of heparin concentrations using calibration curves. Thus, the proposed method would help reduce the risks of protamine overdose in heparin neutralization and would be a helpful tool in clinical practices that use heparin and protamine.
引用
收藏
页码:1561 / 1566
页数:6
相关论文
共 50 条
  • [31] Polypyrrole-based Enzyme Electrode with Immobilized Glucose Oxidase for Electrochemical Determination of Glucose
    Jugovic, Branimir
    Grgur, Branimir
    Antov, Mirjana
    Knezevic-Jugovic, Zorica
    Stevanovic, Jasmina
    Gvozdenovic, Milica
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (02): : 1152 - 1161
  • [32] An enzymatic biofuel cell based on electrically wired polyphenol oxidase and glucose oxidase operating under physiological conditions
    Giroud, Fabien
    Gondran, Chantal
    Gorgy, Karine
    Vivier, Vincent
    Cosnier, Serge
    ELECTROCHIMICA ACTA, 2012, 85 : 278 - 282
  • [33] THE BENEFICIAL-EFFECTS OF AMINOPHYLLINE ADMINISTRATION ON HEPARIN REVERSAL WITH PROTAMINE
    KATIRCIOGLU, SF
    KUCUKAKSU, DS
    BOZDAYI, M
    DALVA, K
    MAVITAS, B
    ZORLUTUNA, Y
    TASDEMIR, O
    BAYAZIT, K
    SURGERY TODAY-THE JAPANESE JOURNAL OF SURGERY, 1994, 24 (02): : 99 - 102
  • [34] Determination of Glucose with Biosensor by Immobilization of Glucose Oxidase with Chitosan
    Zhang Yan
    Nan Cai-Feng
    Feng Li
    Zhang Li-Qin
    Dong Chuan
    Shuang Shao-Min
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (07) : 1049 - 1052
  • [35] Acid phosphatase/glucose oxidase-based biosensors for the determination of pesticides
    Mazzei, F
    Botre, F
    Botre, C
    ANALYTICA CHIMICA ACTA, 1996, 336 (1-3) : 67 - 75
  • [36] ATTEMPTS: a heparin/protamine-based triggered release system for the delivery of enzyme drugs without associated side-effects
    Park, YJ
    Liang, JF
    Song, H
    Li, YT
    Naik, S
    Yang, VC
    ADVANCED DRUG DELIVERY REVIEWS, 2003, 55 (02) : 251 - 265
  • [37] Amperometric determination of glucose, based on the direct electron transfer between glucose oxidase and tin oxide
    Jae Yeon Park
    Yang Hee Kim
    Andrew Seong
    Young Je Yoo
    Biotechnology and Bioprocess Engineering, 2008, 13 : 431 - 435
  • [38] Preserved enzymatic activity of glucose oxidase immobilized on unmodified electrodes for glucose detection
    Wang, Gang
    Thai, Ngee Mei
    Yau, Siu-Tung
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10) : 2158 - 2164
  • [39] Effects of protamine and heparin can be detected and easily differentiated by modified thrombelastography (Rotem®):: an in vitro study
    Mittermayr, M
    Margreiter, J
    Velik-Salchner, C
    Klingler, A
    Streif, W
    Fries, D
    Innerhofer, P
    BRITISH JOURNAL OF ANAESTHESIA, 2005, 95 (03) : 310 - 316
  • [40] Potentiometric glucose determination in human serum samples with glucose oxidase biosensor based on iodide electrode
    E. Karakuş
    Ş. Pekyardımcı
    E. Kiliç
    Applied Biochemistry and Microbiology, 2013, 49 : 194 - 198