Open-Phase Fault-Tolerant DTC Technique for Three-Level NPC VSI-Fed Five-Phase Induction Motor Drives

被引:7
|
作者
Chikondra, Bheemaiah [1 ,2 ]
Yepes, Alejandro G. [3 ]
Al Zaabi, Omar [1 ]
Al Hosani, Khalifa [1 ]
Gandoy, Jesus Doval [3 ]
Behera, Ranjan Kumar [4 ]
机构
[1] Khalifa Univ, Dept Elect Engn & Comp Sci, Abu Dhabi 127788, U Arab Emirates
[2] Vellore Inst Technol, Sch Elect Engn, Vellore 632014, Tamil Nadu, India
[3] Univ Vigo, CINTECX, Appl Power Elect Technol APET Res Grp, Vigo 36310, Spain
[4] Indian Inst Technol IIT Patna, Dept Elect Engn, Bihta 801103, India
关键词
Fault tolerant systems; Fault tolerance; Stators; Switches; Voltage control; Torque measurement; Torque; Common-mode voltage (CMV); direct torque control (DTC); fault-tolerant drive; five-phase induction motor (FPIM) drive; three-level neutral-point-clamped (NPC) inverter; virtual vectors (VVs); DIRECT TORQUE CONTROL; CONTROL STRATEGIES; MACHINES; OPERATION; VOLTAGE; DESIGN;
D O I
10.1109/JESTPE.2022.3224529
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The demand for motor drives based on multiphase machines (MMs) is increasing due to their inherent fault-tolerant capabilities. To achieve satisfactory post-fault operation, a proper fault-tolerant controller is needed. Some direct-torque-control (DTC) techniques have been reported for five-phase induction motor (FPIM) drives under an open-phase fault (OPF). DTC offers simplicity, fast response, and less parameter sensitivity. However, the existing fault-tolerant DTC methods were designed for two-level voltage-source inverters (VSIs). A threelevel neutral-point-clamped (NPC) VSI allows greater flexibility in the switching states, lower current and torque ripple, and reduced common-mode voltage (CMV). However, the increased number of switching states requires the design of new DTC methods, able to tolerate OPFs while providing satisfactory performance in various aspects. In this article, two fault-tolerant DTC techniques are developed for three-level NPC VSI-fed FPIM drives under an OPF. The possible switching states are synthesized with suitable virtual vectors (VVs), addressing the dc-link voltage balance, dv/dt, CMV, and dc-link utilization. The two methods are compared under an OPF in these terms, as well as regarding the average switching frequency. Comparative experimental results are provided to assess the viability of the developed DTC schemes at steady-state and dynamic conditions.
引用
收藏
页码:2114 / 2125
页数:12
相关论文
共 50 条
  • [41] A Simple, Fast, and Robust Open-Phase Fault Detection Technique for Six-Phase Induction Motor Drives
    Duran, Mario J.
    Gonzalez-Prieto, Ignacio
    Rios-Garcia, Natalia
    Barrero, Federico
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (01) : 547 - 557
  • [42] Fault-Tolerant Control of Common Electrical Faults in Dual Three-Phase PMSM Drives Fed by T-Type Three-Level Inverters
    Wang, Xueqing
    Wang, Zheng
    Gu, Minrui
    Xu, Zhixian
    Zou, Zhixiang
    Wang, Wei
    Cheng, Ming
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2021, 57 (01) : 481 - 491
  • [43] Adaptive Fault-Tolerant Control for Open-Circuit Faults in Dual Three-Phase PMSM Drives
    Shi, Pengchuan
    Wang, Xueqing
    Meng, Xin
    He, Mingzhi
    Mao, Yao
    Wang, Zheng
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (03) : 3676 - 3688
  • [44] A Simple, Fast and Robust Open-phase Fault Control Strategies for Five-Phase Induction Motor Drives with Parallel Converters without Common Mode Voltage
    Khadar, Saad
    Kouzou, Abdellah
    Benguesmia, Hani
    2019 4TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND THEIR APPLICATIONS (ICPEA), 2019,
  • [45] Flux-modification-based Fault-tolerant DTC for Five-phase PMSM
    Liu G.
    Gao M.
    Zhou H.
    Zhou C.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (02): : 359 - 365
  • [46] Comparative study of different fault-tolerant control strategies for a five-phase concentrated-full-pitch winding induction motor
    He, Shan
    Sui, Xin
    Blaabjerg, Frede
    2019 21ST EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE '19 ECCE EUROPE), 2019,
  • [47] New Fault-Tolerant Control Strategy of Five-Phase Induction Motor with Four-Phase and Three-Phase Modes of Operation
    Rangari, Sonali Chetan
    Suryawanshi, Hiralal Murlidhar
    Renge, Mohan
    ELECTRONICS, 2018, 7 (09):
  • [48] Comparative Study of DTC and RFOC Methods for the Open-Phase Fault Operation of a 5-Phase Induction Motor Drive
    Bermudez, M.
    Guzman, H.
    Gonzalez-Prieto, I.
    Barrero, F.
    Duran, M. J.
    Kestelyn, X.
    IECON 2015 - 41ST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2015, : 2702 - 2707
  • [49] Enhanced Model Predictive Torque Control of Fault-Tolerant Five-Phase Permanent Magnet Synchronous Motor With Harmonic Restraint and Voltage Preselection
    Huang, Wentao
    Hua, Wei
    Chen, Fuyang
    Zhu, Jianguo
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (08) : 6259 - 6269
  • [50] Common-Mode Voltage and Vibration Mitigation of a Five-Phase Three-Level NPC Inverter-Fed Induction Motor Drive System
    Payami, Saifullah
    Behera, Ranjan Kumar
    Iqbal, Atif
    Al-Ammari, Rashid
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2015, 3 (02) : 349 - 361