Open-Phase Fault-Tolerant DTC Technique for Three-Level NPC VSI-Fed Five-Phase Induction Motor Drives

被引:7
|
作者
Chikondra, Bheemaiah [1 ,2 ]
Yepes, Alejandro G. [3 ]
Al Zaabi, Omar [1 ]
Al Hosani, Khalifa [1 ]
Gandoy, Jesus Doval [3 ]
Behera, Ranjan Kumar [4 ]
机构
[1] Khalifa Univ, Dept Elect Engn & Comp Sci, Abu Dhabi 127788, U Arab Emirates
[2] Vellore Inst Technol, Sch Elect Engn, Vellore 632014, Tamil Nadu, India
[3] Univ Vigo, CINTECX, Appl Power Elect Technol APET Res Grp, Vigo 36310, Spain
[4] Indian Inst Technol IIT Patna, Dept Elect Engn, Bihta 801103, India
关键词
Fault tolerant systems; Fault tolerance; Stators; Switches; Voltage control; Torque measurement; Torque; Common-mode voltage (CMV); direct torque control (DTC); fault-tolerant drive; five-phase induction motor (FPIM) drive; three-level neutral-point-clamped (NPC) inverter; virtual vectors (VVs); DIRECT TORQUE CONTROL; CONTROL STRATEGIES; MACHINES; OPERATION; VOLTAGE; DESIGN;
D O I
10.1109/JESTPE.2022.3224529
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The demand for motor drives based on multiphase machines (MMs) is increasing due to their inherent fault-tolerant capabilities. To achieve satisfactory post-fault operation, a proper fault-tolerant controller is needed. Some direct-torque-control (DTC) techniques have been reported for five-phase induction motor (FPIM) drives under an open-phase fault (OPF). DTC offers simplicity, fast response, and less parameter sensitivity. However, the existing fault-tolerant DTC methods were designed for two-level voltage-source inverters (VSIs). A threelevel neutral-point-clamped (NPC) VSI allows greater flexibility in the switching states, lower current and torque ripple, and reduced common-mode voltage (CMV). However, the increased number of switching states requires the design of new DTC methods, able to tolerate OPFs while providing satisfactory performance in various aspects. In this article, two fault-tolerant DTC techniques are developed for three-level NPC VSI-fed FPIM drives under an OPF. The possible switching states are synthesized with suitable virtual vectors (VVs), addressing the dc-link voltage balance, dv/dt, CMV, and dc-link utilization. The two methods are compared under an OPF in these terms, as well as regarding the average switching frequency. Comparative experimental results are provided to assess the viability of the developed DTC schemes at steady-state and dynamic conditions.
引用
收藏
页码:2114 / 2125
页数:12
相关论文
共 50 条
  • [31] Comparative Performance Analysis of DTC fed Three-Phase and Five-Phase Induction Motor
    Pandey, Richa
    Panda, Anup Kumar
    Patnaik, Nishant
    2020 5TH INTERNATIONAL CONFERENCE ON DEVICES, CIRCUITS AND SYSTEMS (ICDCS' 20), 2020, : 162 - 166
  • [32] Torque Ripple Minimization of a Five-Phase Induction Motor Under Open-Phase Faults Using Symmetrical Components
    He, Shan
    Sui, Xin
    Liu, Zijian
    Kang, Min
    Zhou, Dao
    Blaabjerg, Frede
    IEEE ACCESS, 2020, 8 (08): : 114675 - 114691
  • [33] Optimization-Based Maximum-Torque Fault-Tolerant Control of Dual Three-Phase PMSM Drives Under Open-Phase Fault
    Jin, Luhan
    Mao, Yao
    Wang, Xueqing
    Shi, Pengchuan
    Lu, Linlin
    Wang, Zheng
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (03) : 3653 - 3663
  • [34] Torque Ripple Suppression Under Open-Phase Fault Conditions in a Five-Phase Induction Motor With Harmonic Injection
    Liu, Haitao
    Wang, Dong
    Yi, Xinqiang
    Meng, Fanqing
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2021, 9 (01) : 274 - 288
  • [35] Performance Comparison of Five-Phase Three-Level NPC to Five-Phase Two-Level Voltage Source Inverter
    Bheemaiah, Ch
    Muduli, Utkal Ranjan
    Behera, Ranjan Kumar
    2018 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2018,
  • [36] Single-Phase Open-Circuit Fault-Tolerant Control for a Dual Five-Phase Permanent Magnet Motor With Multioperational Modes
    Liu, Yu
    Chen, Qian
    Chen, Shulong
    Ding, Wenqiang
    Liu, Guohai
    Zhao, Wenxiang
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2024, 10 (04): : 9591 - 9600
  • [37] Direct torque control of three-level five-phase inverter-fed five-phase induction motor with common-mode voltage elimination
    Tatte, Yogesh
    Paramane, Ashish
    ELECTRICAL ENGINEERING, 2023, 105 (01) : 243 - 257
  • [38] Fault Tolerant Multi-level Five-Phase Open-End Winding Drives
    Darijevic, Milan
    Jones, Martin
    2014 49TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2014,
  • [39] Natural Fault-tolerant Switching-table-based DTC for Five-phase PMSM
    Zhou H.
    Chen C.
    Zhao Y.
    Jiang G.
    Zhang D.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2024, 44 (04): : 1618 - 1628
  • [40] Research on Open Circuit Fault Modeling and Fault Tolerant Control Strategy of Five-Phase Induction Motor
    Xu, Hao
    Zhao, Jinghong
    Yang, Lv
    Chen, Hansi
    Luo, Xiangyu
    Zhang, Shuheng
    PROCESSES, 2022, 10 (09)