A Highly Versatile X-ray and Electron Beam Diamond Dosimeter for Radiation Therapy and Protection

被引:17
作者
Pettinato, Sara [1 ,2 ]
Girolami, Marco [2 ]
Stravato, Antonella [3 ]
Serpente, Valerio [2 ]
Musio, Daniela [3 ]
Rossi, Maria C. [4 ]
Trucchi, Daniele M. [2 ]
Olivieri, Riccardo [3 ]
Salvatori, Stefano [1 ,2 ]
机构
[1] Niccolo Cusano Univ, Engn Fac, Via Don Carlo Gnocchi 3, I-00166 Rome, Italy
[2] Consiglio Nazl Ric ISM CNR, Ist Struttura Mat, DiaTHEMA Lab, Str Prov 35D 9, I-00010 Rome, Italy
[3] Azienda Osped San Giovanni Addolorata, Via Amba Aradam 8, I-00184 Rome, Italy
[4] Univ Roma Tre, Dept Ind Elect & Mech Engn, Via Vito Volterra 62, I-00146 Rome, Italy
关键词
radiation therapy; radiation protection; dosimetry; CVD diamond detectors; electron beams; X-rays; SINGLE-CRYSTAL; DETECTORS; PHOTON;
D O I
10.3390/ma16020824
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Radiotherapy is now recognized as a pillar in the fight against cancer. Two different types are currently used in clinical practice: (1) external beam radiotherapy, using high-energy X-rays or electron beams, both in the MeV-range, and (2) intraoperative radiotherapy, using low-energy X-rays (up to 50 keV) and MeV-range electron beams. Versatile detectors able to measure the radiation dose independently from the radiation nature and energy are therefore extremely appealing to medical physicists. In this work, a dosimeter based on a high-quality single-crystal synthetic diamond sample was designed, fabricated and characterized under low-energy X-rays, as well as under high-energy pulsed X-rays and electron beams, demonstrating excellent linearity with radiation dose and dose-rate. Detector sensitivity was measured to be 0.299 +/- 0.002 mu C/Gy under 6 MeV X-ray photons, and 0.298 +/- 0.004 mu C/Gy under 6 MeV electrons, highlighting that the response of the diamond dosimeter is independent of the radiation nature. Moreover, in the case of low-energy X-rays, an extremely low limit of detection (23 nGy/s) was evaluated, pointing out the suitability of the device to radiation protection dosimetry.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] SILICONE COMPOSITES FOR X-RAY PROTECTION
    Jankauskaite, Virginija
    Griskonis, Egidijus
    Lisauskaite, Aiste
    Plaipaite-Nalivaiko, Rita
    Kleveckas, Tadas
    MEDICAL PHYSICS IN THE BALTIC STATES, 2013, : 173 - 177
  • [42] How linearly polarized is the X-ray beam from the X-ray generator?
    Tanaka, S
    Tsunemi, H
    Hayashida, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (9A): : 5770 - 5773
  • [43] X-ray Spectroscopy Based on Polycrystalline Diamond
    Girolami, M.
    Allegini, P.
    Salvatori, S.
    Conte, G.
    Spiriti, E.
    Ralchenko, V.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5034 - +
  • [44] Cancer Cell Metabolism: Implications for X-ray and Particle Radiation Therapy
    Sertorio, Mathieu
    Perentesis, John P.
    Vatner, Ralph E.
    Mascia, Anthony E.
    Zheng, Yi
    Wells, Susanne I.
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2018, 5 (01): : 40 - 48
  • [45] Optimization of Transmission X-ray Target for Intense Pulsed Electron Beam Accelerators
    Yu, Xiao
    Zhang, Shijian
    Egorov, Ivan Sergeevich
    Zhao, Jiangqi
    Xiong, Chang
    Yan, Sha
    Tan, Chang
    Remnev, Gennady Efimovich
    Le, Xiaoyun
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [46] Comparison of the effect of X-ray and electron beam irradiation on the microbiological quality of foodstuffs
    Van Calenberg, S
    Van Cleemput, O
    Mondelaers, W
    Huyghebaert, A
    FOOD SCIENCE AND TECHNOLOGY-LEBENSMITTEL-WISSENSCHAFT & TECHNOLOGIE, 1999, 32 (06): : 372 - 376
  • [47] Electron and photon spread contributions to the radiological penumbra for small monoenergetic x-ray beam (≤2 MeV)
    Pignol, Jean-Philippe
    Keller, Brian M.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (10)
  • [48] Graded-gap AlxGa1-xAs high-energy X-ray radiation dosimeter
    Silenas, Aldis
    Miller, Albert
    Pozela, Juras
    Pozela, Karolis
    Dapkus, Leonas
    Juciene, Vida
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01) : 71 - 74
  • [49] Beam Coherence and X-ray Windows
    Khounsary, Ali
    Lai, Barry
    Qian, Jun
    Khachatryan, Ruben
    Maj, Josef
    Huang, Xianrong
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS V, 2010, 7802
  • [50] Ultra-thin optical grade scCVD diamond as X-ray beam position monitor
    Desjardins, Kewin
    Pomorski, Michal
    Morse, John
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 1217 - 1223