A Highly Versatile X-ray and Electron Beam Diamond Dosimeter for Radiation Therapy and Protection

被引:18
作者
Pettinato, Sara [1 ,2 ]
Girolami, Marco [2 ]
Stravato, Antonella [3 ]
Serpente, Valerio [2 ]
Musio, Daniela [3 ]
Rossi, Maria C. [4 ]
Trucchi, Daniele M. [2 ]
Olivieri, Riccardo [3 ]
Salvatori, Stefano [1 ,2 ]
机构
[1] Niccolo Cusano Univ, Engn Fac, Via Don Carlo Gnocchi 3, I-00166 Rome, Italy
[2] Consiglio Nazl Ric ISM CNR, Ist Struttura Mat, DiaTHEMA Lab, Str Prov 35D 9, I-00010 Rome, Italy
[3] Azienda Osped San Giovanni Addolorata, Via Amba Aradam 8, I-00184 Rome, Italy
[4] Univ Roma Tre, Dept Ind Elect & Mech Engn, Via Vito Volterra 62, I-00146 Rome, Italy
关键词
radiation therapy; radiation protection; dosimetry; CVD diamond detectors; electron beams; X-rays; SINGLE-CRYSTAL; DETECTORS; PHOTON;
D O I
10.3390/ma16020824
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Radiotherapy is now recognized as a pillar in the fight against cancer. Two different types are currently used in clinical practice: (1) external beam radiotherapy, using high-energy X-rays or electron beams, both in the MeV-range, and (2) intraoperative radiotherapy, using low-energy X-rays (up to 50 keV) and MeV-range electron beams. Versatile detectors able to measure the radiation dose independently from the radiation nature and energy are therefore extremely appealing to medical physicists. In this work, a dosimeter based on a high-quality single-crystal synthetic diamond sample was designed, fabricated and characterized under low-energy X-rays, as well as under high-energy pulsed X-rays and electron beams, demonstrating excellent linearity with radiation dose and dose-rate. Detector sensitivity was measured to be 0.299 +/- 0.002 mu C/Gy under 6 MeV X-ray photons, and 0.298 +/- 0.004 mu C/Gy under 6 MeV electrons, highlighting that the response of the diamond dosimeter is independent of the radiation nature. Moreover, in the case of low-energy X-rays, an extremely low limit of detection (23 nGy/s) was evaluated, pointing out the suitability of the device to radiation protection dosimetry.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] A Versatile FG-MOSFET Inverter Design for X-Ray Radiation Dosimetry Applications
    Yadegari, Behzad
    Roy, Langis
    Ghaffar, Farhan A.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2021, 15 (05) : 1008 - 1016
  • [32] Radiation hygiene in medical X-ray imaging
    Brix, G.
    Veit, R.
    Haeusler, U.
    RADIOLOGE, 2010, 50 (10): : 913 - 925
  • [33] Application of the Sunna dosimeter film in gamma and electron beam radiation processing
    Kovacs, A
    Baranyai, M
    Wojnarovits, L
    McLaughlin, WL
    Miller, SD
    Miller, A
    Fuochi, PG
    Lavalle, M
    Slezsak, I
    RADIATION PHYSICS AND CHEMISTRY, 2000, 57 (3-6) : 691 - 695
  • [34] Recent development of thin diamond crystals for X-ray FEL beam-sharing
    Feng, Yiping
    Alonso-Mori, Roberto
    Blank, Vladimir
    Boutet, Sebastien
    Chollet, Mathieu
    van Driel, Tim Brandt
    Fritz, David M.
    Glownia, James M.
    Hastings, Jerome B.
    Lemke, Henrik
    Messerchmidt, Marc
    Montanez, Paul A.
    Robert, Aymeric
    Robinson, Joseph
    Samoylova, Liubov
    Shvyd'ko, Yuri
    Sikorski, Marcin
    Sinn, Harald
    Song, Sanghoon
    Srinivasan, Venkat N.
    Stoupin, Stanislav
    Terentiev, Sergey
    Williams, Garth
    Zhu, Diling
    ADVANCES IN X-RAY FREE-ELECTRON LASERS II: INSTRUMENTATION, 2013, 8778
  • [35] Single-Pulse Measurement Electronics for Accurate Dosimetry in X-ray Radiation Therapy
    Pettinato, Sara
    Olivieri, Riccardo
    Salvatori, Stefano
    2021 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (IEEE MEMEA 2021), 2021,
  • [36] Coherent X-ray Radiation from a Relativistic Electron in a Combined Medium
    Blazhevich, S. V.
    Noskov, A. V.
    JOURNAL OF EXPERIMENTAL AND THEORETICAL PHYSICS, 2014, 118 (04) : 550 - 559
  • [37] Evaluation of the MOSkin dosimeter for diagnostic X-ray CT beams
    Pereira, L. Mendes
    Khoury, H. J.
    Andrade, M. E. A.
    Barros, V. S. M.
    Cutajar, D.
    Rosenfeld, A. B.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 60 : 150 - 155
  • [38] The effect of annealing on the X-ray induced photocurrent characteristics of CVD diamond radiation detectors with different electrical contacts
    Abdel-Rahman, Mohamed A. E.
    Lohstroh, Annika
    Sellin, Paul J.
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2011, 208 (09): : 2079 - 2086
  • [39] X-ray spectrometry for calculating conversion coefficients from air kerma to operational quantities in radiation protection
    Plagnard, Johann
    Lefevre, Jeremie
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (03)
  • [40] SILICONE COMPOSITES FOR X-RAY PROTECTION
    Jankauskaite, Virginija
    Griskonis, Egidijus
    Lisauskaite, Aiste
    Plaipaite-Nalivaiko, Rita
    Kleveckas, Tadas
    MEDICAL PHYSICS IN THE BALTIC STATES, 2013, : 173 - 177