Fluorescence Anisotropy in Radachlorin and Chlorin e6 in Water-Methanol Solutions under One- and Two-Photon Excitation

被引:7
|
作者
Gorbunova, Ioanna A. [1 ]
Sasin, Maxim E. [1 ]
Zhikhoreva, Anna A. [1 ]
Belashov, Andrey V. [1 ]
Beltukova, Dina M. [1 ]
Semenova, Irina V. [1 ]
Vasyutinskii, Oleg S. [1 ]
机构
[1] Russian Acad Sci, Ioffe Inst, 26,Polytekhnicheskaya, St Petersburg 194021, Russia
基金
俄罗斯科学基金会;
关键词
Radachlorin; chlorin e6; fluorescent analysis; TCSPC; polarized fluorescence; fluorescence anisotropy; rotational diffusion time; PHOTODYNAMIC THERAPY; PHOTOSENSITIZER; POLARIZATION; CELLS; NADH; HEMATOPORPHYRIN; LOCALIZATION; SPECTROSCOPY; RELAXATION; SENSITIZER;
D O I
10.3390/photonics10010009
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The fluorescence anisotropy of photosensitizers Radachlorin and chlorin e6 was studied using the time-resolved single photon-counting technique under one- and two-photon excitation within the Soret absorption band. A very small negative anisotropy was observed in both photosensitizers under one-photon excitation in the vicinity of the absorption maximum within the wavelength range of 395-405 nm. Meanwhile, two-photon excitation of the photosensitizers in the same spectral range demonstrated high fluorescence anisotropy with the maximum value of about 0.43. The drastic difference of the fluorescence anisotropy parameters at one- and two-photon excitation modes was suggested to be due to the different symmetries of one- and two-photon absorption tensors when two-photon absorption tensor components have comparable values. The variation of excitation wavelengths in the spectral range of 375-425 nm demonstrated nonlinear wavelength dependence of anisotropy of both Radachlorin and chlorin e6, with opposite tendencies at one- and two-photon excitation. The data obtained suggest that one-photon excitation at about 405 nm often utilized in FLIM experiments is not sensitive to fluorescence anisotropy in Radachlorin and chlorin e6 and therefore cannot be used for the determination of anisotropy/rotational diffusion time in these molecules. Meanwhile, two-photon excitation can provide high fluorescence anisotropy and accurate determination of the rotational diffusion time. At the same time, one-photon excitation at about 405 nm can be used for the accurate evaluation of fluorescence lifetimes within the standard FLIM schematic where fluorescence polarization is not taken into account.
引用
收藏
页数:13
相关论文
共 11 条
  • [1] Photophysics of chlorin e6: from one- and two-photon absorption to fluorescence and phosphorescence
    Gattuso, Hugo
    Monari, Antonio
    Marazzi, Marco
    RSC ADVANCES, 2017, 7 (18) : 10992 - 10999
  • [2] Two-photon excited polarized fluorescence in NADH in methanol/water solutions
    Gorbunova, I. A.
    Bezverkhnii, N. O.
    Zhikhoreva, A. A.
    Beltukov, Y. M.
    Sasin, M. E.
    Rubayo-Soneira, J.
    Vasyutinskii, O. S.
    ADVANCES IN MICROSCOPIC IMAGING II, 2019, 11076
  • [3] Photodamage of mesotetraphenylporphyrin under one- and two-photon excitation
    Wen, Ya-nan
    Liu, Yu-qiang
    Yang, Zhen-ling
    Yang, Yan-qiang
    Guo, Xi-ming
    JOURNAL OF APPLIED PHYSICS, 2010, 108 (04)
  • [4] Two-Photon Excited Fluorescence Dynamics in NADH in Water-Methanol Solutions: The Role of Conformation States
    Gorbunova, Ioanna A.
    Sasin, Maxim E.
    Rubayo-Soneira, Jesus
    Smolin, Andrey G.
    Vasyutinskii, Oleg S.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2020, 124 (47) : 10682 - 10697
  • [5] Two-photon excited quantum dots as energy donors for photosensitizer chlorin e6
    Skripka, Artiom
    Valanciunaite, Jurga
    Dauderis, Gediminas
    Poderys, Vilius
    Kubiliute, Reda
    Rotomskis, Ricardas
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (07)
  • [6] Fluorescence Anisotropy of Tyrosinate Anion Using One-, Two- and Three-Photon Excitation
    Kierdaszuk, Borys
    JOURNAL OF FLUORESCENCE, 2013, 23 (02) : 339 - 347
  • [7] Exciton Luminescence Dynamics in ZnO Crystal Observed under One- and Two-Photon Excitation
    Yamamoto, Sekika
    Sakuma, Hikari
    Mishina, Tomobumi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (12)
  • [8] Anisotropic fluorescence decay kinetics in FAD in water-methanol solutions under excitation at 355 and 450 nm
    Krasnopevtceva, Marina K.
    Sasin, Maxim E.
    Gorbunova, Ioanna A.
    Golyshev, Dmitry P.
    Smolin, Andrey G.
    Belik, Viktor
    Vasyutinskii, Oleg S.
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS XI, 2021, 11900
  • [9] Fluorescence anisotropy of indole molecules under two-photon excitation in the spectral range of 485-510 nm
    Sasin, M. E.
    Tushkanov, V. I.
    Smolin, A. G.
    Vasyutinskii, O. S.
    OPTICS AND SPECTROSCOPY, 2017, 123 (04) : 569 - 573
  • [10] Fluorescence anisotropy in indole under two-photon excitation in the spectral range 385-510 nm
    Sasin, M. E.
    Smolin, A. G.
    Gericke, K. -H.
    Tokunaga, E.
    Vasyutinskii, O. S.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2018, 20 (30) : 19922 - 19931