Effectiveness of mechanical recanalization for intraluminal occlusion of totally implantable venous access ports

被引:4
|
作者
Yang, Woo Jin [1 ]
Song, Myung Gyu [1 ]
Seo, Tae-Seok [1 ]
Park, Sung-Joon [2 ]
机构
[1] Korea Univ, Guro Hosp, Coll Med, Dept Radiol, 148 Gurodong Ro, Seoul, South Korea
[2] Korea Univ, Ansan Hosp, Coll Med, Dept Radiol, Ansan, Gyeonggi Do, South Korea
关键词
Venous access port; mechanical recanalization; intraluminal occlusion; clot occlusion; saline injection; TISSUE-PLASMINOGEN ACTIVATOR; RECOMBINANT UROKINASE; CATHETER OCCLUSION; DOUBLE-BLIND; VASCULAR ACCESS; SINGLE-ARM; OPEN-LABEL; PHASE-III; DEVICES; RESTORATION;
D O I
10.1177/11297298211034628
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: To evaluate if the mechanical injection of saline is effective in restoring patency of a totally implantable venous access port (TIVAP) with an intraluminal occlusion. Materials and methods: From January 2017 to June 2019, 64 cases of dysfunction of a TIVAP were referred to interventional radiology. Among these, 16 cases showed normal function of the TIVAP, 19 cases the showed the appearance of a fibroblastic sheath, and 29 cases showed intraluminal occlusion. Mechanical recanalization was performed for intraluminal occlusion of the TIVAP with an indeflator and a 20G non-coring needle. Linograms were performed in all recanalized cases. The success or failure of recanalization and the pressure of the indeflator were recorded. Linograms were evaluated for breakage or migration of catheters. Medical records were retrospectively reviewed. Results: Among the 29 intraluminal occlusion cases, 24 cases (82.7%) were recanalized by mechanical recanalization via an indeflator. The pressure of the indeflator ranged from 29 to 220 psi (median: 118 psi). Linograms revealed breakage of the catheter of the TIVAP in two failed cases. The median interval from implantation to dysfunction was 405 days (range: 43-1723 days). The median interval from last use to dysfunction was 8 days (mean: 15.4 days; range: 1-119 days). The median re-occlusion free period after successful mechanical recanalization was 100.5 days (range: 6-859 days). Conclusion: In the absence of an available thrombolytic agent, mechanical injection of saline was a tolerable alternative method for restoring occluded catheters and sustaining the function of catheters. Because breakage of the catheter can occur during mechanical recanalization of a TIVAP, a linogram should follow the procedure.
引用
收藏
页码:430 / 435
页数:6
相关论文
共 50 条
  • [1] Mechanical recanalization for clot occlusion of venous access ports: experimental study using ports with clot occlusion
    Song, Myung Gyu
    Seo, Tae-Seok
    Kim, Baek-hui
    Kim, Jeong Ho
    JOURNAL OF VASCULAR ACCESS, 2017, 18 (02) : 158 - 162
  • [2] Safety of 3-month flushing interval for prevention of occlusion in totally implantable venous access ports: An analysis focused on intraluminal clots
    Yang, Woo Jin
    Song, Myung Gyu
    Seo, Tae-Seok
    Kang, Danbee
    Park, Sung-Joon
    Kwak, Jung Won
    JOURNAL OF VASCULAR ACCESS, 2024,
  • [3] Femoral Placement of Totally Implantable Venous Access Ports in Patients with Bilateral Breast Cancer
    Almasi-Sperling, V.
    Hieber, S.
    Lermann, J.
    Strahl, O.
    Beckmann, M. W.
    Lang, W.
    Sagban, T. A.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2016, 76 (01) : 53 - 58
  • [4] Venous cutdown versus the Seldinger technique for placement of totally implantable venous access ports
    Hsu, Charlie C-T
    Kwan, Gigi N. C.
    Evans-Barns, Hannah
    Rophael, John A.
    van Driel, Mieke L.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (08):
  • [5] Complications after percutaneous placement of totally implantable venous access ports in the forearm
    Goltz, J. P.
    Petritsch, B.
    Thurner, A.
    Hahn, D.
    Kickuth, R.
    CLINICAL RADIOLOGY, 2012, 67 (11) : 1101 - 1107
  • [6] Malfunction of Totally Implantable Central Venous Ports
    Kim, Hyo-Cheol
    Hur, Saebeom
    Jeon, Hoyong
    IRANIAN JOURNAL OF RADIOLOGY, 2017, 14 (01)
  • [7] Totally implantable central venous access ports in patients with cystic fibrosis: a multicenter prospective cohort study
    Dal Molin, Alberto
    Di Massimo, Dino Stefano
    Braggion, Cesare
    Bisogni, Sofia
    Rizzi, Elena
    D'Orazio, Ciro
    Di Toppa, Maria Vittoria
    Alghisi, Federico
    Cristadoro, Simona
    Carnovale, Vincenzo
    Festa, Gabriella
    Rampini, Serena
    Colombo, Carla
    Oneta, Anna
    Furnari, Maria Lucia
    Calamia, Maria Antonietta
    Zunino, Maria Luisa
    Tuccio, Giuseppe
    Spadea, Vincenzo
    Messore, Barbara
    Grosso, Bianca
    Festini, Filippo
    JOURNAL OF VASCULAR ACCESS, 2012, 13 (03) : 290 - 295
  • [8] Clinical applications and research progress of totally implantable venous access ports: a literature review
    Huang, Xiao-Min
    Li, Xia
    Deng, Jie
    Chen, Jiong
    Qian, Liang
    FRONTIERS IN ONCOLOGY, 2025, 14
  • [9] Cutdowns for Totally Implantable Access Ports to Central Veins
    Kulaylat, Mahmoud
    Karakousis, Constantine P.
    VASCULAR, 2009, 17 (05) : 273 - 276
  • [10] Late complications of totally implantable venous access ports in patients with cancer Risk factors and related nursing strategies
    Yu, Xin-Yan
    Xu, Jia-Lan
    Li, Dan
    Jiang, Zi-Fang
    MEDICINE, 2018, 97 (38)