Quantitative MRI assessment of joint effusion using T2-relaxometry at 3 Tesla: a feasibility and reproducibility study

被引:1
作者
van Leeuwen, Flora H. P. [1 ]
Lena, Beatrice [1 ]
van Bergen, Eline D. P. [2 ]
van Klei, Janoah J. [1 ]
Timmer, Merel A. [2 ]
van Vulpen, Lize F. D. [2 ]
Fischer, Kathelijn [2 ]
de Jong, Pim A. [1 ]
Bos, Clemens [1 ]
Foppen, Wouter [1 ]
机构
[1] Univ Utrecht, Univ Med Ctr Utrecht, Dept Radiol & Nucl Med, Div Imaging & Oncol, HP E01 132,POB 85500, NL-3584 CX Utrecht, Netherlands
[2] Univ Utrecht, Univ Med Ctr Utrecht, Ctr Benign Haematol Thrombosis & Haemostasis, Van Creveldklin, HP C01 428,POB 85500, NL-3584 CX Utrecht, Netherlands
关键词
Magnetic resonance imaging; Haemarthrosis; Synovial fluid; Haemophilia; Reproducibility of results; HEMOPHILIC ARTHROPATHY; MUSCULOSKELETAL ULTRASOUND; RELAXATION-TIMES; OSTEOARTHRITIS; MANAGEMENT; BLOOD; KNEE; HIP;
D O I
10.1007/s00256-024-04652-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectiveT2-relaxometry could differentiate between physiological and haemorrhagic joint effusion (>= 5% blood) in vitro. Are quantitative T2-relaxation time measurements of synovial fluid feasible and reproducible in vivo in clinically bleed-free joints of men with haemophilia?Materials and methodsIn this cross-sectional study, we measured T2-relaxation times of synovial fluid in clinically bleed-free ankles, knees or elbows of men with severe haemophilia A using a T2-mapping sequence (duration <= 7 min) at 3 Tesla MRI. Manual and circular regions of interest (ROI) were drawn in the synovial fluid of each joint by two independent observers to measure T2-relaxation times. Measurement feasibility was expressed as the success rate of the measurements by both observers. The interobserver and intraobserver reproducibility of the measurements were evaluated by the intraclass correlation coefficient of absolute agreement (ICC) and the limits of agreement (LoA) from Bland Altman analysis.ResultsWe evaluated 39 clinically bleed-free joints (11 ankles, 12 knees, 16 elbows) of 39 men (median age, 24 years; range 17-33) with severe haemophilia A. The success rate of the T2-measurements was >= 90%. Interobserver reliability was good to excellent (manual ROI: ICC = 0.92, 95% CI 0.76-0.97; circular ROI: ICC = 0.82, 95% CI 0.66-0.91) and interobserver agreement was adequate (manual ROI: LoA = 71 ms; circular ROI: LoA = 146 ms). Intraobserver reliability was good to excellent (manual ROI: ICC = 0.78, 95% CI - 0.06-0.94; circular RO: ICC = 0.99, 95% CI 0.98-0.99) and intraobserver agreement was good (manual ROI: LoA = 63 ms; circular ROI: LoA = 41 ms).ConclusionT2-relaxometry of synovial fluid in haemophilia patients is feasible with good interobserver and intraobserver reproducibility.
引用
收藏
页码:2389 / 2398
页数:10
相关论文
共 33 条
[1]   Haemophilia [J].
Berntorp, Erik ;
Fischer, Kathelijn ;
Hart, Daniel P. ;
Mancuso, Maria Elisa ;
Stephensen, David ;
Shapiro, Amy D. ;
Blanchette, Victor .
NATURE REVIEWS DISEASE PRIMERS, 2021, 7 (01)
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Brown RW., 2014, 8 INTRO SIGNAL ACQUI, P113
[4]   MRI of synovitis and joint fluid [J].
Burke, Christopher J. ;
Alizai, Hamza ;
Beltran, Luis S. ;
Regatte, Ravinder R. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (06) :1512-1527
[5]   Rapid musculoskeletal ultrasound for painful episodes in adult haemophilia patients [J].
Ceponis, A. ;
Wong-Sefidan, I. ;
Glass, C. S. ;
von Drygalski, A. .
HAEMOPHILIA, 2013, 19 (05) :790-798
[6]   ACUTE HEMATOMAS - EFFECTS OF DEOXYGENATION, HEMATOCRIT, AND FIBRIN-CLOT FORMATION AND RETRACTION ON T2 SHORTENING [J].
CLARK, RA ;
WATANABE, AT ;
BRADLEY, WG ;
ROBERTS, JD .
RADIOLOGY, 1990, 175 (01) :201-206
[7]   The use of confidence or fiducial limits illustrated in the case of the binomial. [J].
Clopper, CJ ;
Pearson, ES .
BIOMETRIKA, 1934, 26 :404-413
[8]   Sonographic and CT findings in lipohemarthrosis [J].
Costa, Daniel N. ;
Cavalcanti, Conrado F. A. ;
Sernik, Renato A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (04) :W389-W389
[9]   When to use agreement versus reliability measures [J].
de Vet, Henrica C. W. ;
Terwee, Caroline B. ;
Knol, Dirk L. ;
Bouter, Lex M. .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2006, 59 (10) :1033-1039
[10]   State-of-the-art imaging techniques for the evaluation of haemophilic arthropathy: present and future [J].
Doria, A. S. .
HAEMOPHILIA, 2010, 16 :107-114