The yield of cytology and histology obtained by endoscopic ultrasound-guided fine needle aspiration and biopsy needles in the diagnosis of pancreatic adenocarcinoma

被引:2
|
作者
Sbeit, Wisam [1 ]
Abu Hanna, Nidaa [1 ]
Alejandro, Livoff [2 ]
Khoury, Tawfik [1 ]
机构
[1] Bar Ilan Univ, Azrieli Fac Med, Galilee Med Ctr, Dept Gastroenterol, Safed, Nahariya, Israel
[2] Bar Ilan Univ, Azrieli Fac Med, Galilee Med Ctr, Pathol Dept, Safed, Nahariya, Israel
关键词
cancer; EUS; FNA; FNB; pancreas; SOCIETY; TUMORS; FNA;
D O I
10.1111/cyt.13306
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Introduction: Endoscopic ultrasound-guided fine needle aspiration and biopsy (EUS-FNA, - FNB) are the mainstay for tissue diagnosis of pancreatic lesions. Traditionally, FNA was performed for obtaining cytology and also histology if available from the puncture. Since their advent, however, FNB needles have been intended mainly to obtain core biopsies for histological specimens.Aims: We aimed to assess the yield of cytology obtained via both FNA and FNB needles.Methods: A retrospective study was performed including all patients who were diagnosed with pancreatic adenocarcinoma obtained via EUS-FNA/FNB needles. Results: Overall, 227 patients were included. Of them, 85 patients underwent FNB, versus 142 patients who had FNA. The average age in the FNB group was 70.46 +/- 11.29 years, versus 71.44 +/- 11.80 in the FNA group, P = 0.57. Notably, cytological analysis diagnosed malignancy equally in both groups (69.4% in the FNB group, vs. 65.5% in the FNA group). The compatibility rate of cytology with histology was 76.5% in the FNB group, versus 76.1% in the FNA group (P = 0.69). The agreement level between cytology obtained by FNA and FNB, versus histology obtained by both needles, was moderate (kappa = 0.48, 95% CI 0.39-0.57). Similarly, the agree-ment level between cytology and histology in the FNB group was moderate as well (kappa = 0.5, 95% CI 0.36-0.64).Conclusion: Cytological assessment yielded an equal performance as compared to histological assessment with both needles. We recommend obtaining cytology specimens in pancreatic solid lesion puncture by FNB needle.
引用
收藏
页码:92 / 97
页数:6
相关论文
共 50 条
  • [21] Evaluation of endoscopic ultrasound-guided fine-needle aspiration biopsy for pancreatic lesions
    Min, Chenzhi
    Xing, Jianghai
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2013, 28 : 881 - 881
  • [22] Diagnostic yield of endoscopic ultrasound-guided fine needle aspiration for solid pancreatic lesions
    Holt, N.
    Aslam, P.
    Aggarwal, V.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2017, 32 : 41 - 42
  • [23] Review of endoscopic ultrasound-guided fine-needle aspiration cytology
    Bardales, RH
    Stelow, EB
    Mallery, S
    Lai, R
    Stanley, MW
    DIAGNOSTIC CYTOPATHOLOGY, 2006, 34 (02) : 140 - 175
  • [24] Accuracy of endoscopic ultrasound-guided fine-needle aspiration in the suspicion of pancreatic metastases
    Ardengh, Jose Celso
    Lopes, Cesar Vivian
    Kemp, Rafael
    Venco, Filadelfio
    de Lima-Filho, Eder Rios
    dos Santos, Jose Sebastiao
    BMC GASTROENTEROLOGY, 2013, 13
  • [25] Implication of Suspicious Cytology in Endoscopic Ultrasound-Guided Fine-Needle Aspiration for Pancreatic Cancer
    Shi J.
    Lew M.
    Zalupski M.M.
    Roh M.H.
    Kwon R.S.
    Pang J.C.
    Journal of Gastrointestinal Cancer, 2015, 46 (1) : 54 - 59
  • [26] Clinical impact of preoperative endoscopic ultrasound-guided fine-needle aspiration for pancreatic ductal adenocarcinoma
    Tsutsumi, Hideharu
    Hara, Kazuo
    Mizuno, Nobumasa
    Hijioka, Susumu
    Imaoka, Hiroshi
    Tajika, Masahiro
    Tanaka, Tsutomu
    Ishihara, Makoto
    Yoshimura, Kenichi
    Shimizu, Yasuhiro
    Niwa, Yasumasa
    Sasaki, Yutaka
    Yamao, Kenji
    ENDOSCOPIC ULTRASOUND, 2016, 5 (02) : 94 - 100
  • [27] Endoscopic ultrasound-guided fine-needle aspiration cytology diagnosis of intraductal papillary mucinous neoplasm of the pancreas is highly predictive of pancreatic neoplasia
    Emerson, Robert E.
    Randolph, Melissa L.
    Cramer, Harvey M.
    DIAGNOSTIC CYTOPATHOLOGY, 2006, 34 (07) : 457 - 462
  • [28] Endoscopic ultrasound-guided fine needle aspiration of pancreatic lesions with 22 versus 25 Gauge needles: A meta-analysis
    Facciorusso, Antonio
    Stasi, Elisa
    Di Maso, Marianna
    Serviddio, Gaetano
    Ali Hussein, Mohammed Salah
    Muscatiello, Nicola
    UNITED EUROPEAN GASTROENTEROLOGY JOURNAL, 2017, 5 (06) : 846 - 853
  • [29] Current Concept of Endoscopic Ultrasound-Guided Fine Needle Aspiration for Pancreatic Cancer
    Mizuno, Nobumasa
    Hara, Kazuo
    Hijioka, Susumu
    Bhatia, Vikram
    Shimizu, Yasuhiro
    Yatabe, Yasushi
    Yamao, Kenji
    PANCREATOLOGY, 2011, 11 : 40 - 46
  • [30] Tips for endoscopic ultrasound-guided fine needle aspiration of various pancreatic lesions
    Yasuda, Ichiro
    Iwashita, Takuji
    Doi, Shinpei
    JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2014, 21 (05) : E29 - E33