Toric Trifocal Intraocular Lens for Refractive Lens Exchange: A Multi-center, Multi-surgeon Large Cohort Study

被引:3
作者
Wallerstein, Avi [1 ,2 ,7 ]
Gauvin, Mathieu [1 ,2 ]
Trottier, Pierre [2 ,3 ]
Cohen, Mark [2 ,3 ]
Lloyd, John [2 ,4 ]
Racine, Louis [2 ,5 ]
Albert, Darren [1 ,2 ]
Ahmed, Iqbal Ike K. [4 ]
Mimouni, Michael [6 ]
机构
[1] McGill Univ, Dept Ophthalmol & Visual Sci, Montreal, PQ, Canada
[2] LASIK MD, Montreal, PQ, Canada
[3] Univ Sherbrooke, Dept Surg, Sherbrooke, PQ, Canada
[4] Univ Toronto, Dept Ophthalmol & Vis Sci, Toronto, ON, Canada
[5] Univ Montreal, Dept Ophthalmol, Montreal, PQ, Canada
[6] Technion Israel Inst Technol, Rambam Hlth Care Campus, Dept Ophthalmol, Bruce & Ruth Rappaport Fac Med, Haifa, Israel
[7] 1250 Rene Levesque Blvd West,MD Level, Montreal, PQ H3B 4W8, Canada
关键词
EXTENDED DEPTH; CATARACT-SURGERY; VISUAL OUTCOMES; IMPLANTATION; ASTIGMATISM; PERFORMANCE; STANDARD;
D O I
10.3928/1081597X-20230308-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the outcomes of a novel toric trifocal intraocular lens (IOL) for refractive lens exchange (RLE) in a large series of eyes with corneal astigmatism. METHODS: Consecutive eyes that underwent RLE with the PanOptix Toric IOL (Alcon Laboratories, Inc) were included. Outcomes measures included postoperative distance (UDVA), 60 cm intermediate (UIVA), and 40 cm near (UNVA) uncorrect-ed visual acuity, manifest refraction, spherical and defocus equivalent, efficacy and safety indices, and vector analyses of refractive and toric IOL accuracy. RESULTS: A total of 4,933 eyes had a median follow-up of 3 months. UDVA of 20/20 and 20/40 was obtained in 65% and 99% of eyes monocularly and 87% and 100% binocularly, respectively. UIVA at 60 cm of 20/25 and 20/40 was achieved in 70% and 99% of eyes monocularly and in 77% and 100% binocularly, respectively. UNVA at 40 cm of 20/25 and 20/40 was achieved in 85% and 96% of eyes monocularly and in 95% and 100% binocularly, respectively. A total of 67%, 89%, 97%, and 99% of eyes had a SEQ within 0.25, 0.50, 0.75, and 1.00 diopter (D) of intended target (R2 = 0.99). Post-operative refractive astigmatism of 0.50, 0.75, and 1.00 D or less was achieved in 86%, 95%, and 98% of eyes. The vector analysis correction index and index of success were 1.04 +/- 0.35 and 0.41 +/- 0.31 for toric IOL accuracy and 1.00 +/- 0.46 and 0.36 +/- 0.55 for re-fractive accuracy, respectively. The 3-and 12-month post-RLE ex-cimer laser enhancement rates were 1.1% (95% CI: 0.8% to 1.4%) and 7.6% (95% CI: 6.9% to 8.3%), respectively. CONCLUSIONS: The PanOptix Toric IOL performed well for a wide range of axial lengths and corneal astigmatism in eyes that had RLE. Most patients achieved effective uncorrected binocular near, intermediate, and distance vision for daily functioning. [J Refract Surg. 2023;39(5):302-310.]
引用
收藏
页码:302 / +
页数:12
相关论文
共 31 条
[1]   Vector analysis of astigmatic changes after cataract surgery with implantation of a new toric multifocal intraocular lens [J].
Alio, Jorge L. ;
Pinero, David P. ;
Tomas, Javier ;
Plaza, Ana B. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (07) :1217-1229
[2]   Astigmatism analysis by the Alpins method [J].
Alpins, N .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (01) :31-49
[3]   Presbyopic refractive lens exchange with trifocal intraocular lens implantation after corneal laser vision correction: Refractive results and biometry analysis [J].
Brenner, Luis F. ;
Gjerdrum, Bjorn ;
Aakre, Bente Monica ;
Lundmark, Per Olof ;
Nistad, Kristin .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10) :1404-1415
[4]   Refractive and Visual Outcomes After Bilateral Implantation of a Trifocal Intraocular Lens in a Large Population [J].
Carreno, Edgardo ;
Carreno, Edgardo A. ;
Carreno, Rodrigo ;
Carreno, Maricarmen ;
Lopez, Veronica ;
Potvin, Richard .
CLINICAL OPHTHALMOLOGY, 2020, 14 :369-376
[5]   A Comparative Evaluation of a New Generation of Diffractive Trifocal and Extended Depth of Focus Intraocular Lenses [J].
Cochener, Beatrice ;
Boutillier, Guillaume ;
Lamard, Mathieu ;
Auberger-Zagnoli, Claire .
JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (08) :507-+
[6]   Distribution of preoperative and postoperative astigmatism in a large population of patients undergoing cataract surgery in the UK [J].
Day, Alexander C. ;
Dhariwal, Mukesh ;
Keith, Michael S. ;
Ender, Frank ;
Vives, Caridad Perez ;
Miglio, Cristiana ;
Zou, Lu ;
Anderson, David F. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (07) :993-1000
[7]   Short term visual outcomes of a new trifocal intraocular lens [J].
Garcia-Perez, Jorge L. ;
Gros-Otero, Juan ;
Sanchez-Ramos, Celia ;
Blazquez, Vanesa ;
Contreras, Ines .
BMC OPHTHALMOLOGY, 2017, 17
[8]   Clinically Relevant Optical Properties of Bifocal, Trifocal, and Extended Depth of Focus Intraocular Lenses [J].
Gatinel, Damien ;
Loicq, Jerome .
JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (04) :273-+
[9]   AstigMATIC: an automatic tool for standard astigmatism vector analysis [J].
Gauvin, Mathieu ;
Wallerstein, Avi .
BMC OPHTHALMOLOGY, 2018, 18
[10]   Subjective Perception Of Trifocal IOL Performance, Including Toric Models [J].
Hamdi, Islam Mahmoud .
CLINICAL OPHTHALMOLOGY, 2019, 13 :1955-1961