A Comparative Review on Single Phase Transformerless Inverter Topologies for Grid-Connected Photovoltaic Systems

被引:16
作者
Kibria, Md. Faruk [1 ,2 ]
Elsanabary, Ahmed [3 ,4 ]
Tey, Kok Soon [5 ]
Mubin, Marizan [1 ]
Mekhilef, Saad [1 ,3 ,6 ]
机构
[1] Univ Malaya, Dept Elect Engn, Power Elect & Renewable Energy Res Lab PEARL, Kuala Lumpur 50603, Malaysia
[2] Hajee Mohammad Danesh Sci & Technol Univ, Dept Elect & Elect Engn, Dinajpur 5200, Bangladesh
[3] Univ Tenaga Nas, Inst Power Engn IPE, Kajang 43000, Malaysia
[4] Port Said Univ, Dept Elect Engn, Port Said 42526, Egypt
[5] Univ Malaya, Fac Comp Sci & Informat Technol, Kuala Lumpur 50603, Malaysia
[6] Swinburne Univ Technol, Sch Sci Comp & Engn Technol, Hawthorn, Vic 3122, Australia
关键词
AC decoupling; DC decoupling; grid-connected inverter; leakage current; mid-point clamping; solidly clamping; total common mode voltage; transformerless inverter; LEAKAGE CURRENT SUPPRESSION; MOSFET INVERTER; POWER QUALITY; PV INVERTER; MODULATION; MPPT; H5;
D O I
10.3390/en16031363
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The uses of grid-connected photovoltaic (PV) inverters are increasing day by day due to the scarcity of fossil fuels such as coal and gas. On the other hand, due to their superior efficiency, lower cost, smaller size, and lighter weight when compared to inverters with transformers, transformerless inverters for low-voltage single-phase grid-tied photovoltaic (PV) systems have recently attracted more interest. However, there are some specific challenges, especially leakage current issues, which must be adequately addressed to ensure the safety standards of the grid codes. A variety of topologies has been presented in the literature to eliminate the leakage current using the decoupling or clamping technique. However, choosing an appropriate topology after comparison is challenging because each topology has a unique set of parameters. In this paper, the authors have selected a common set of parameters and simulated all the selected eighteen well-known topologies in MATLAB/Simulink to fairly analyze and compare their common mode characteristics and other output parameters. In addition, the power loss distribution of every switch of each of the eighteen topologies was calculated and presented to better understand the insight of the topologies.
引用
收藏
页数:24
相关论文
共 99 条
[1]  
[Anonymous], 2010, 6100032 EN EPSMA
[2]  
[Anonymous], 2000, 9292000 IEEE
[3]  
[Anonymous], 2012, G8322012 ENA
[4]  
[Anonymous], 2005, 477722005 AS
[5]  
[Anonymous], 2006, V012611 VDE
[6]  
[Anonymous], 2012, Technical Requirements for Connecting Photovoltaic Power Station to Power System
[7]  
[Anonymous], 2007, PSIM User's Guide
[8]  
[Anonymous], 2008, GUID GEN PLANTS CONN
[9]  
[Anonymous], 2002, 61727 CDV IEC
[10]  
[Anonymous], 2011, 41052011 VDE AR N