Recurrent neural network-based simultaneous cardiac T1, T2, and T1ρ mapping

被引:1
作者
Tao, Yiming [1 ]
Lv, Zhenfeng [1 ]
Liu, Wenjian [1 ]
Qi, Haikun [2 ,3 ,4 ]
Hu, Peng [2 ,3 ,4 ]
机构
[1] ShanghaiTech Univ, Sch Biomed Engn, Shanghai, Peoples R China
[2] ShanghaiTech Univ, Sch Biomed Engn, 4th Floor,BME Bldg,393 Middle Huaxia Rd, Shanghai 201210, Peoples R China
[3] ShanghaiTech Univ, State Key Lab Adv Med Mat & Devices, Shanghai, Peoples R China
[4] ShanghaiTech Univ, Shanghai Clin Res & Trial Ctr, Shanghai, Peoples R China
关键词
Bloch simulation; cardiac quantitative multiparametric mapping; dictionary matching; LSTM; MAGNETIC-RESONANCE; MYOCARDIAL T1; ENDOGENOUS ASSESSMENT; HEART; T-1; INJURY;
D O I
10.1002/nbm.5133
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of the current study was to explore the feasibility of training a deep neural network to accelerate the process of generating T1, T2, and T1 rho maps for a recently proposed free-breathing cardiac multiparametric mapping technique, where a recurrent neural network (RNN) was utilized to exploit the temporal correlation among the multicontrast images. The RNN-based model was developed for rapid and accurate T1, T2, and T1 rho estimation. Bloch simulation was performed to simulate a dataset of more than 10 million signals and time correspondences with different noise levels for network training. The proposed RNN-based method was compared with a dictionary-matching method and a conventional mapping method to evaluate the model's effectiveness in phantom and in vivo studies at 3 T, respectively. In phantom studies, the RNN-based method and the dictionary-matching method achieved similar accuracy and precision in T1, T2, and T1 rho estimations. In in vivo studies, the estimated T1, T2, and T1 rho values obtained by the two methods achieved similar accuracy and precision for 10 healthy volunteers (T1: 1228.70 +/- 53.80 vs. 1228.34 +/- 52.91 ms, p > 0.1; T2: 40.70 +/- 2.89 vs. 41.19 +/- 2.91 ms, p > 0.1; T1 rho: 45.09 +/- 4.47 vs. 45.23 +/- 4.65 ms, p > 0.1). The RNN-based method can generate cardiac multiparameter quantitative maps simultaneously in just 2 s, achieving 60-fold acceleration compared with the dictionary-matching method. The RNN-accelerated method offers an almost instantaneous approach for reconstructing accurate T1, T2, and T1 rho maps, being much more efficient than the dictionary-matching method for the free-breathing multiparametric cardiac mapping technique, which may pave the way for inline mapping in clinical applications.
引用
收藏
页数:11
相关论文
共 44 条
[11]   Machine Learning for Rapid Magnetic Resonance Fingerprinting Tissue Property Quantification [J].
Hamilton, Jesse I. ;
Seiberlich, Nicole .
PROCEEDINGS OF THE IEEE, 2020, 108 (01) :69-85
[12]   MR Fingerprinting for Rapid Quantification of Myocardial T1, T2, and Proton Spin Density [J].
Hamilton, Jesse I. ;
Jiang, Yun ;
Chen, Yong ;
Ma, Dan ;
Lo, Wei-Ching ;
Griswold, Mark ;
Seiberlich, Nicole .
MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (04) :1446-1458
[13]   Assessing Myocardial Disease Using T1ρ MRI [J].
Han Y. ;
Liimatainen T. ;
Gorman R.C. ;
Witschey W.R.T. .
Current Cardiovascular Imaging Reports, 2014, 7 (2) :1-9
[14]   Cartesian dictionary-based native T1 and T2 mapping of the myocardium [J].
Henningsson, Markus .
MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (05) :2347-2362
[15]   Magnetic Resonance Fingerprinting Reconstruction Using Recurrent Neural Networks [J].
Hoppe, Elisabeth ;
Thamm, Florian ;
Koerzdoerfer, Gregor ;
Syben, Christopher ;
Schirrmacher, Franziska ;
Nittka, Mathias ;
Pfeuffer, Josef ;
Meyer, Heiko ;
Maier, Andreas .
GERMAN MEDICAL DATA SCIENCES: SHAPING CHANGE - CREATIVE SOLUTIONS FOR INNOVATIVE MEDICINE (GMDS 2019), 2019, 267 :126-133
[16]   Deep Learning for Magnetic Resonance Fingerprinting: A New Approach for Predicting Quantitative Parameter Values from Time Series [J].
Hoppe, Elisabeth ;
Koerzdoerfer, Gregor ;
Wuerfl, Tobias ;
Wetzl, Jens ;
Lugauer, Felix ;
Pfeuffer, Josef ;
Maier, Andreas .
GERMAN MEDICAL DATA SCIENCES: VISIONS AND BRIDGES, 2017, 243 :202-206
[17]   T2 measurement of the human myocardium using a T2-prepared transient-state TrueFISP sequence [J].
Huang, Teng-Yi ;
Liu, Yi-Jui ;
Stemmer, Alto ;
Poncelet, Brigitte P. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (05) :960-966
[18]   Noncontrast T1 Mapping for the Diagnosis of Cardiac Amyloidosis [J].
Karamitsos, Theodoros D. ;
Piechnik, Stefan K. ;
Banypersad, Sanjay M. ;
Fontana, Marianna ;
Ntusi, Ntobeko B. ;
Ferreira, Vanessa M. ;
Whelan, Carol J. ;
Myerson, Saul G. ;
Robson, Matthew D. ;
Hawkins, Philip N. ;
Neubauer, Stefan ;
Moon, James C. .
JACC-CARDIOVASCULAR IMAGING, 2013, 6 (04) :488-497
[19]   Heart motion-adapted MR velocity mapping of blood velocity distribution downstream of aortic valve prostheses: Initial experience [J].
Kozerke, S ;
Hasenkam, JM ;
Nygaard, H ;
Paulsen, PK ;
Pedersen, EM ;
Boesiger, P .
RADIOLOGY, 2001, 218 (02) :548-555
[20]   Accelerated cardiac T1 mapping with recurrent networks and cyclic, model-based loss [J].
Le, Johnathan V. ;
Mendes, Jason K. ;
McKibben, Nicholas ;
Wilson, Brent D. ;
Ibrahim, Mark ;
DiBella, Edward V. R. ;
Adluru, Ganesh .
MEDICAL PHYSICS, 2022, 49 (11) :6986-7000