Investigation of (3E) energy, exergy, and environmental analysis of syngas production for combined power and cooling plant by testing six different biomasses

被引:0
作者
Parvez, Mohd [1 ]
Khan, Osama [2 ]
Howari, Haidar [3 ]
机构
[1] Al Falah Univ, Dept Mech Engn, Faridabad, Haryana, India
[2] Jamia Millia Islamia, Dept Mech Engn, New Delhi 110025, India
[3] Qassim Univ, Dept Phys, Deanship Educ Serv, Buraydah 51452, Al Qassim, Saudi Arabia
关键词
Gas turbine; Steam turbine; HRSG; Solid waste; Apple bagasse; OXIDE FUEL-CELL; GASIFICATION; PERFORMANCE; SYSTEM;
D O I
10.1007/s13399-023-04746-0
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Six significant biomasses were examined in this communication to determine their respective thermodynamic performances. To recover the waste heat extracted from the HRSG, the proposed system integrates a gas turbine, a steam turbine, and a vapour absorption at the bottom. The investigation's sole goal is to determine how well thermodynamic processes perform from an energy, exergy, and environmental standpoint. The results reveal a clear trend wherein the increase in turbine inlet temperature from 1273 to 1473 K leads to a concurrent rise in both energy and exergy efficiencies. Additionally, apple bagasse material has the lowest energy and exergy efficiencies compared to solid waste material, which has the best thermodynamic performance of about (37.6% and 35.9%). Additionally, the combustion chamber (apple bagasse) is noted to have the highest exergy destruction at about 32.1%, followed by the HRSG and gasifier at about 16.3% and 11.3%, respectively.
引用
收藏
页码:24265 / 24279
页数:15
相关论文
共 44 条