Next generation of flow analysis is based on flow programming

被引:8
|
作者
Ruzicka, Jaromir [1 ]
Chocholous, Petr [2 ]
机构
[1] Univ Hawaii, Dept Oceanog, 1000 Pope Rd, Honolulu, HI 96822 USA
[2] Charles Univ Prague, Fac Pharm Hradec Kralove, Dept Analyt Chem, Akad Heyrovskeho 1203, Hradec Kralove 50003, Czech Republic
关键词
Programmable flow analysis; Spectrophotometry; Sea water; Schlieren effect; Automated calibration by single standard; solution; Lab-on-valve; REACTIVE PHOSPHORUS; ESTUARINE WATERS; INJECTION; SILICATE;
D O I
10.1016/j.talanta.2023.125410
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Concepts of air Segmented Flow Analysis (SFA) and Flow Injection Analysis (FIA) are discussed and compared with the performance of a new method based on comprehensive flow programming. The programmable Flow Injection (pFI), miniaturized on the lab-on-valve platform, can perform tasks that can not be done in any other way, such as Auto calibration by a single standard solution or analysis in a flow-batch mode that exactly simulates the traditional manual batch technique. Performance of pFI is documented by examples of nutrient de-terminations in sea water.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Development of a flow method for the determination of phosphate in estuarine and freshwaters-Comparison of flow cells in spectrophotometric sequential injection analysis
    Mesquita, Raquel B. R.
    Ferreira, M. Teresa S. O. B.
    Toth, Ildiko V.
    Bordalo, Adriano A.
    McKelvie, Ian D.
    Rangel, Antonio O. S. S.
    ANALYTICA CHIMICA ACTA, 2011, 701 (01) : 15 - 22
  • [2] Temperature-dependent schlieren effect in liquid flow for chemical analysis
    Suwanrut, Jintana
    Chantipmanee, Nattapong
    Kamsong, Wichayaporn
    Buking, Supatana
    Mantim, Thitirat
    Saetear, Phoonthawee
    Nacapricha, Duangjai
    TALANTA, 2018, 188 : 74 - 80
  • [3] Loop flow analysis of dissolved reactive phosphorus in aqueous samples
    Ma, Jian
    Li, Quanlong
    Yuan, Dongxing
    TALANTA, 2014, 123 : 218 - 223
  • [4] Automated calibration by a single standard solution prepared in deionized water by flow programming eliminates the schlieren and salinity effects and is applied to the determination of phosphate in sea water of different salinities
    Hatta, M.
    Ruzicka, J.
    Measures, C.
    Davis, M.
    TALANTA, 2023, 253
  • [5] Flow-based methods and their applications in chemical analysis
    Timofeeva, Irina
    Nugbienyo, Lawrence
    Pochivalov, Aleksei
    Vakh, Christina
    Shishov, Andrey
    Bulatov, Andrey
    CHEMTEXTS, 2021, 7 (04)
  • [6] Flow injection analysis of nanomolar silicate using long pathlength absorbance spectroscopy
    Ma, Jian
    Byrne, Robert H.
    TALANTA, 2012, 88 : 484 - 489
  • [7] Multi-reflection photometric flow cell for use in flow injection analysis of estuarine waters
    Ellis, PS
    Lyddy-Meaney, AJ
    Worsfold, PJ
    McKelvie, ID
    ANALYTICA CHIMICA ACTA, 2003, 499 (1-2) : 81 - 89
  • [8] Applications of flow techniques in seawater analysis: A review
    Ma, Jian
    Yuan, Dongxing
    Lin, Kunning
    Feng, Sichao
    Zhou, Tingjin
    Li, Quanlong
    TRENDS IN ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2016, 10 : 1 - 10
  • [9] Programmable flow injection in batch mode: Determination of nutrients in sea water by using a single, salinity independent calibration line, obtained with standards prepared in distilled water
    Hatta, Mariko
    Ruzicka, Jaromir
    Measures, Christopher, I
    Davis, Madeline
    TALANTA, 2021, 232
  • [10] The third generation of flow injection analysis: Current situation and perspectives of Lab-on-Valve scheme
    Wang, JH
    Fang, ZL
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (10) : 1401 - 1406