Characterisation of HEXITECMHz- A 1 MHz continuous frame rate spectroscopic X-ray imaging detector system

被引:3
|
作者
Cline, B. D. [1 ]
Banks, D. [1 ]
Bell, S. [1 ]
Church, I. [1 ]
Cross, S. [1 ]
Davis, A. [1 ]
Day, C. [1 ]
French, M. [1 ]
Gardiner, T. [1 ]
Ghorbanian, N. [1 ]
Harris, J. [1 ]
Hart, M. [1 ]
Holden, J. [1 ]
Jones, L. [1 ]
Lipp, J. [1 ]
Nicholls, T. [1 ]
Nobes, J. [1 ]
Pradeep, S. [1 ]
Prydderch, M. [1 ]
Roberts, M. [1 ]
Schneider, A. [1 ]
Seller, P. [1 ]
Sole, D. [1 ]
Veale, M. C. [1 ]
Wilson, M. D. [1 ]
Helsby, W. [2 ]
Dhamgaye, V. [3 ]
Fox, O. [3 ]
Sawhney, K. [3 ]
机构
[1] UKRI STFC Rutherford Appleton Lab, Didcot OX11 0QX, Oxon, England
[2] UKRI STFC Daresbury Lab, Daresbury WA4 4AD, Warrington, England
[3] Diamond Light Source, Didcot OX11 0DE, Oxon, England
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2023年 / 1057卷
关键词
Pixel detector; MHz imaging; P-type Si; Resolution; X-ray spectroscopy; X-ray imaging; PERFORMANCE; ENERGY;
D O I
10.1016/j.nima.2023.168718
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Spectroscopic X-ray imaging techniques including Compton X-ray Imaging, X-ray Fluorescence Imaging and Hyperspectral X-ray Tomography require energy-resolving detectors capable of operating at high incident X-ray fluxes to make time resolved measurements. HEXITECMHz, operates at a continuous 1 MHz frame rate and can make fully spectroscopic measurements at >10(6) ph s(-1) mm(-2). This is enabled by an integrating Front End, in-pixel digitisation and high-speed serialisers. A 300 mu m thick p-type Si HEXITECMHz detector was characterised on the B16 Test Beamline at the Diamond Light Source and are the first measurements taken at a 1 MHz frame rate. At 10 keV and 15 keV) the device displayed average FWHM of 656 eV and 682 eV respectively, with minimal changes in spectroscopic performance over similar to 8 h. Analysis of charge-sharing events show low charge loss and a linear energy-signal response. Higher-flux measurements illustrated the capability of the ASIC to operate as a photon-counting device.
引用
收藏
页数:12
相关论文
共 21 条
  • [1] MHz frame rate hard X-ray phase-contrast imaging using synchrotron radiation
    Olbinado, Margie P.
    Just, Xavier
    Gelet, Jean-Louis
    Lhuissier, Pierre
    Scheel, Mario
    Vagovic, Patrik
    Sato, Tokushi
    Graceffa, Rita
    Schulz, Joachim
    Mancuso, Adrian
    Morse, John
    Rack, Alexander
    OPTICS EXPRESS, 2017, 25 (12): : 13857 - 13871
  • [2] The Controlled-Drift Detector:: a new detector for fast frame readout X-ray imaging
    Castoldi, A
    Gatti, E
    Guazzoni, C
    Longoni, A
    Rehak, P
    Strüder, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 461 (1-3): : 405 - 409
  • [3] Review of hybrid pixel detector readout ASICs for spectroscopic X-ray imaging
    Ballabriga, R.
    Alozy, J.
    Campbell, M.
    Frojdh, E.
    Heijne, E. H. M.
    Koenig, T.
    Llopart, X.
    Marchal, J.
    Pennicard, D.
    Poikela, T.
    Tlustos, L.
    Valerio, P.
    Wong, W.
    Zuber, M.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [4] Characterisation of the HEXITEC4S X-ray spectroscopic imaging detector incorporating through-silicon via (TSV) technology
    Veale, M. C.
    Booker, P.
    Church, I.
    Jones, L. L.
    Lipp, J.
    Schneider, A.
    Seller, P.
    Wilson, M. D.
    Chsherbakov, I.
    Kolesnikova, I.
    Lozinskaya, A.
    Novikov, V.
    Tolbanov, O.
    Tyazhev, A.
    Zarubin, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1025
  • [5] Spectroscopic-grade X-ray imaging up to 100-kHz frame rate with controlled-drift detectors
    Castoldi, A
    Guazzoni, C
    Rehak, P
    Strüder, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 982 - 986
  • [6] Digital CZT Detector System for High Flux Energy-Resolved X-ray Imaging
    Abbene, L.
    Principato, F.
    Gerardi, G.
    Benassi, G.
    Zambelli, N.
    Zappettini, A.
    Bettelli, M.
    Seller, P.
    Veale, M. C.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [7] Spectroscopic Imaging with an X-ray Microscopy Setup Using a Pixelated Detector with Single Photon Processing
    Norlin, Borje
    Frojdh, Christer
    Thungstrom, Goran
    Greiffenberg, Dominic
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2739 - +
  • [8] Pixel Drift Detector (PixDD) - SIRIO: an X-ray spectroscopic system with high energy resolution at room temperature
    Sammartini, M.
    Gandola, M.
    Mele, F.
    Bertuccio, G.
    Ambrosino, F.
    Bellutti, P.
    Borghi, G.
    Campana, R.
    Caselle, M.
    Cirrincione, D.
    Evangelista, Y.
    Feroci, M.
    Ficorella, F.
    Fiorini, M.
    Fuschino, F.
    Grassi, M.
    Labanti, C.
    Malcovati, P.
    Picciotto, A.
    Rachevski, A.
    Rashevskaya, I
    Zampa, G.
    Zampa, N.
    Zorzi, N.
    Vacchi, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 953
  • [9] Comparative study of CWO and ZnSe(Te) scintillation detector on the performance of X-ray imaging system
    Kwak, SW
    Cho, G
    Kim, BH
    Kim, I
    Jae, MS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 537 (1-2): : 449 - 453
  • [10] Scanning-slit photon counting x-ray imaging system using a microchannel plate detector
    Shikhaliev, PM
    Xu, T
    Le, H
    Molloi, S
    MEDICAL PHYSICS, 2004, 31 (05) : 1061 - 1071