Finite element analysis of sagittal screw expander appliance in the treatment of anterior maxillary hypoplasia

被引:0
作者
Zhang, Jian [1 ]
Liu, Caiyun [2 ]
Dong, Yan [1 ]
机构
[1] Dalian Med Univ, Coll Stomatol, Dalian, Liaoning, Peoples R China
[2] Dalian Med Univ, Affiliated Hosp Stomatol, Dalian, Liaoning, Peoples R China
关键词
finite element analysis; anterior maxillary hypoplasia; sagittal screw expander appliance; displacement; stress distribution; STRESS-DISTRIBUTION; TOOTH-MOVEMENT; PROTRACTION; DISPLACEMENT; EXPANSION; PALATE; DENTITION; IMPLANTS; GROWTH; HYRAX;
D O I
10.3389/fbioe.2023.1245764
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The skeletal anterior crossbite is a common malocclusion in clinic. However, there have been no reports on the maxillary sagittal expansion to correct the premaxillary hypoplasia, which greatly influences the facial morphology and masticatory function, using finite element analysis. In the present study, a three-dimensional finite element model of craniomaxillofacial complex with maxillary sagittal hypoplasia is constructed and the treatment for premaxillary hypoplasia by the sagittal screw expander appliance is simulated. The hypoplasia of the left premaxilla is more serious than that of the right and thus the size of the left part of premaxillary expander baseplate is designed to be larger than that of the right part and the loading is applied at 10 degrees leftward to the sagittal plane and 30 degrees forward and downward to the maxillary occlusal plane. The displacements or equivalent stress distributions of the maxilla, teeth and their periodontal ligaments, are analyzed under the loads of 5.0 N, 10.0 N, 15.0 N, and 20.0 N. Consequently, as the load increases, the displacements or equivalent stresses of the maxilla, teeth and their periodontal ligaments all increase. Almost the whole premaxilla markedly move forward, downward, and leftward while other areas in the craniomaxillofacial complex remain almost static or have little displacement. The equivalent stress concentration zone of the maxilla mainly occurs around and in front of the incisive foramina. The displacements of left premaxilla are generally greater than those of the right under the loading forces. The maximum equivalent stress on the teeth and their periodontal ligaments are 2.34E-02 MPa and 2.98E-03 MPa, respectively. Taken together, the sagittal screw expander appliance can effectively open the premaxillary suture to promote the growth of the premaxilla. An asymmetrical design of sagittal screw expander appliance achieves the asymmetric expansion of the premaxilla to correct the uneven hypoplasia and obtains the more symmetrical aesthetic presentation. This study might provide a solid basis and theoretical guidance for the clinical application of sagittal screw expander appliance in the efficient, accurate, and personalized treatment of premaxillary hypoplasia.
引用
收藏
页数:10
相关论文
共 50 条
[41]   Study of Stress Distribution and Displacement of the Maxillary Complex Following Application of Forces using Jackscrew and Nitanium Palatal Expander 2-A Finite Element Study [J].
Shetty, Preeth ;
Hegde, Amitha M. ;
Rai, Kavita .
JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2009, 34 (01) :87-93
[42]   Evaluation of Stress Distribution of Maxillary Anterior Segment during en Masse Retraction Using Posterior Mini Screw: A Finite Element Study [J].
Ali, Meer Juned ;
Bhardwaj, Amit ;
Khan, Mohammad Shoyab ;
Alwadei, Farhan ;
Gufran, Khalid ;
Alqahtani, Abdullah Saad ;
Alqhtani, Nasser Raqe ;
Alasqah, Mohammed ;
Alsakr, Abdulaziz Mohammad ;
Alghabban, Rawda Omar .
APPLIED SCIENCES-BASEL, 2022, 12 (20)
[43]   Finite Element Analysis of Two Different Implant Applicable for Vertical Bone Deficiency at Maxillary Sinus [J].
Ataol, Mert ;
Kilinc, Adnan ;
Saruhan, Nesrin ;
Gundogdu, Mustafa .
JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2019, 9 (03) :315-321
[44]   Asymmetric Maxillary Protraction for Unilateral Cleft lip and Palate Patients Using Finite Element Analysis [J].
Chen, Zhengxi ;
Pan, Xiaogang ;
Zhao, Ning ;
Chen, Zhenqi ;
Shen, Gang .
JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (02) :388-392
[45]   Effects of different types of maxillary protraction on maxilla with finite element analysis [J].
Buyukcavus, Muhammed Hilmi ;
Kale, Burak .
JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2021, 71 (03) :877-882
[46]   Stress on facial skin of class III subjects during maxillary protraction: a finite element analysis [J].
Gazzani, Francesca ;
Pavoni, Chiara ;
Cozza, Paola ;
Lione, Roberta .
BMC ORAL HEALTH, 2019, 19
[47]   Stress distribution in the closure of anterior maxillary diastemas using different restorative approaches: a finite element analysis [J].
Karakaya, Kevser ;
Erdem, Rahime Zeynep .
CLINICAL ORAL INVESTIGATIONS, 2025, 29 (03)
[48]   Effect of Implant Diameter and Bruxism on Biomechanical Performance in Maxillary All-on-4 Treatment: A 3D Finite Element Analysis [J].
Sezer, Taygun ;
Kilic, Kerem ;
Esim, Emir .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) :709-721
[49]   Biomechanical influence of narrow-diameter implants placed at the crestal and subcrestal level in the maxillary anterior region. A 3D finite element analysis [J].
Cruz, Ronaldo S. ;
Fernandes e Oliveira, Hiskell Francine ;
Lemos, Cleidiel Aparecido Araujo ;
Batista, Victor Eduardo de Souza ;
da Silva, Rodrigo Capalbo ;
Verri, Fellippo R. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (02) :180-187
[50]   Finite element analysis of stress distribution in sagittal split Ramus osteotomy: the influence of impacted third molars [J].
Derin, Ahmet Faruk ;
Alan, Hilal .
ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2025, 29 (01)