Finite element analysis of sagittal screw expander appliance in the treatment of anterior maxillary hypoplasia

被引:0
|
作者
Zhang, Jian [1 ]
Liu, Caiyun [2 ]
Dong, Yan [1 ]
机构
[1] Dalian Med Univ, Coll Stomatol, Dalian, Liaoning, Peoples R China
[2] Dalian Med Univ, Affiliated Hosp Stomatol, Dalian, Liaoning, Peoples R China
关键词
finite element analysis; anterior maxillary hypoplasia; sagittal screw expander appliance; displacement; stress distribution; STRESS-DISTRIBUTION; TOOTH-MOVEMENT; PROTRACTION; DISPLACEMENT; EXPANSION; PALATE; DENTITION; IMPLANTS; GROWTH; HYRAX;
D O I
10.3389/fbioe.2023.1245764
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The skeletal anterior crossbite is a common malocclusion in clinic. However, there have been no reports on the maxillary sagittal expansion to correct the premaxillary hypoplasia, which greatly influences the facial morphology and masticatory function, using finite element analysis. In the present study, a three-dimensional finite element model of craniomaxillofacial complex with maxillary sagittal hypoplasia is constructed and the treatment for premaxillary hypoplasia by the sagittal screw expander appliance is simulated. The hypoplasia of the left premaxilla is more serious than that of the right and thus the size of the left part of premaxillary expander baseplate is designed to be larger than that of the right part and the loading is applied at 10 degrees leftward to the sagittal plane and 30 degrees forward and downward to the maxillary occlusal plane. The displacements or equivalent stress distributions of the maxilla, teeth and their periodontal ligaments, are analyzed under the loads of 5.0 N, 10.0 N, 15.0 N, and 20.0 N. Consequently, as the load increases, the displacements or equivalent stresses of the maxilla, teeth and their periodontal ligaments all increase. Almost the whole premaxilla markedly move forward, downward, and leftward while other areas in the craniomaxillofacial complex remain almost static or have little displacement. The equivalent stress concentration zone of the maxilla mainly occurs around and in front of the incisive foramina. The displacements of left premaxilla are generally greater than those of the right under the loading forces. The maximum equivalent stress on the teeth and their periodontal ligaments are 2.34E-02 MPa and 2.98E-03 MPa, respectively. Taken together, the sagittal screw expander appliance can effectively open the premaxillary suture to promote the growth of the premaxilla. An asymmetrical design of sagittal screw expander appliance achieves the asymmetric expansion of the premaxilla to correct the uneven hypoplasia and obtains the more symmetrical aesthetic presentation. This study might provide a solid basis and theoretical guidance for the clinical application of sagittal screw expander appliance in the efficient, accurate, and personalized treatment of premaxillary hypoplasia.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] The difference of stress distribution of maxillary expansion using rapid maxillary expander (RME) and maxillary skeletal expander (MSE)-a finite element analysis
    Hartono, Nathania
    Soegiharto, Benny M.
    Widayati, Retno
    PROGRESS IN ORTHODONTICS, 2018, 19
  • [2] Biomechanical evaluation of maxillary protraction with an orthodontic anchor screw: a three-dimensional finite element analysis
    Ebisawa, Tomohiro
    Katada, Hidenori
    Sueishi, Kenji
    Nishii, Yasushi
    ORTHODONTIC WAVES, 2021, 80 (03) : 149 - 160
  • [3] The difference of stress distribution of maxillary expansion using rapid maxillary expander (RME) and maxillary skeletal expander (MSE)—a finite element analysis
    Nathania Hartono
    Benny M. Soegiharto
    Retno Widayati
    Progress in Orthodontics, 19
  • [4] Finite Element Analysis of Maxillary Teeth Movement with Time during En Masse Retraction Using Orthodontic Mini-Screw
    Hwang, Jeong-Bo
    Mo, Sung-Seo
    APPLIED SCIENCES-BASEL, 2023, 13 (06):
  • [5] Investigation of the Type of Angled Abutment for Anterior Maxillary Implants: A Finite Element Analysis
    Korkmaz, Ismail Hakki
    Kul, Esra
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (08): : 689 - 696
  • [6] The Hyrax appliance with tooth anchorage variations in surgically assisted rapid maxillary expansion: a finite element analysis
    Silveira Tomazi, Flavio Henrique
    Conci, Ricardo Augusto
    Heitz, Claiton
    Noritomi, Pedro Yoshito
    de Menezes, Luciane Macedo
    Santayana de Lima, Eduardo Martinelli
    Teixeira, Eduardo Rolim
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2023, 27 (04): : 647 - 654
  • [7] Finite Element Analysis of the Influence of the Orthodontic Appliance Design on the Maxillary Expansion
    Bosiakov, S. M.
    Dosta, A. N.
    Vinokurova, A. V.
    IZVESTIYA SARATOVSKOGO UNIVERSITETA NOVAYA SERIYA-MATEMATIKA MEKHANIKA INFORMATIKA, 2013, 13 (04): : 42 - 52
  • [8] Finite element analysis of maxillary orthodontic therapies with variable alveolar bone grafts under occlusal forces in patient with unilateral cleft lip and palate
    Zhang, Zhi
    Li, Chenghao
    Zheng, Qian
    Shi, Bing
    Liu, Renkai
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [9] The effects of clinical crown length on the sagittal movement of maxillary central incisor in clear aligner treatment: a finite element exploration
    Zhou, Chen
    Feng, Zhicai
    Ren, Jianhan
    Luo, Haotian
    Ieong, Hio Cheng
    Li, Runze
    Qing, Yangqiao
    Guo, Yuqing
    Guo, Bingyan
    Huang, Zichun
    Cao, Yang
    Wang, Weicai
    BMC ORAL HEALTH, 2025, 25 (01):
  • [10] Evaluation of dental and skeletal effects of the asymmetric rapid maxillary expansion appliance: A three-dimensional finite element study
    Keser, Merve
    Gulnar, Burak
    Baser, Baris
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (03) : 1039 - 1050