Development of a semi-anthropomorphic photoacoustic calcaneus phantom based on nano computed tomography and stereolithography 3D printing

被引:5
作者
Xu, Zhanpeng [1 ]
Locke, Conor S. [2 ]
Morris, Richard [3 ]
Jamison, DeAndre [1 ]
Kozloff, Kenneth M. [1 ,2 ]
Wang, Xueding [1 ,4 ]
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Orthopaed Surg, Ann Arbor, MI 48109 USA
[3] IF LLC, Stoughton, WI 53589 USA
[4] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
bone; osteoporosis; phantom; photoacoustic; ultrasound; QUANTITATIVE ULTRASOUND; MECHANICAL-PROPERTIES; TRABECULAR BONE; ATTENUATION; TISSUE;
D O I
10.1002/jor.25702
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Osteoporosis is a major public health threat with significant physical, psychosocial, and financial consequences. The calcaneus bone has been used as a measurement site for risk prediction of osteoporosis by noninvasive quantitative ultrasound (QUS). By adding optical contrast to QUS, our previous studies indicate that a combination of photoacoustic (PA) and QUS, that is, PAQUS, provides a novel opportunity to assess the health of human calcaneus. Calibration of the PAQUS system is crucial to realize quantitative and repeatable measurements of the calcaneus. Therefore, a phantom which simulates the optical, ultrasound, and architectural properties of the human calcaneus, for PAQUS system calibration, is required. Additionally, a controllable phantom offers researchers a versatile framework for developing versatile structures, allowing more controlled assessment of how varying bone structures cause defined alterations in PA and QUS signals. In this work, we present the first semi-anthropomorphic calcaneus phantom for PAQUS. The phantom was developed based on nano computed-tomography (nano-CT) and stereolithography 3D printing, aiming to maximize accuracy in the approximation of both trabecular and cortical bone microstructures. Compared with the original digital input calcaneus model from a human cadaveric donor, the printed model achieved accuracies of 71.15% in total structure and 87.21% in bone volume fraction. Inorganic materials including synthetic blood, mineral oil, intralipid, and agar gel were used to model the substitutes of bone marrow and soft tissue, filling and covering the calcaneus phantom. The ultrasound and optical properties of this phantom were measured, and the results were consistent with those measured by a commercialized device and from previous in vivo studies. In addition, a short-term stability test was conducted for this phantom, demonstrating that the optical and ultrasound properties of the phantom were stable without significant variation over 1 month. This semi-anthropomorphic calcaneus phantom shows structural, ultrasound, and optical properties similar to those from a human calcaneus in vivo and, thereby, can serve as an effective source for equipment calibration and the comprehensive study of human patients.
引用
收藏
页码:647 / 660
页数:14
相关论文
共 48 条
  • [1] The Relation Between Calcaneus Stiffness Index as a Measure of Bone Density and Body Mass Index in an Egyptian Cohort
    Ali, Khalid
    El Said, Salma M. S.
    Adly, Nermien N.
    Abdul-Rahman, Samia A.
    [J]. JOURNAL OF MULTIDISCIPLINARY HEALTHCARE, 2019, 12 : 1085 - 1090
  • [2] [Anonymous], GUID STER SLA 3D PRI
  • [3] Optical Scattering Properties of Intralipid Phantom in Presence of Encapsulated Microbubbles
    Assadi, Homa
    Karshafian, Raffi
    Douplik, Alexandre
    [J]. INTERNATIONAL JOURNAL OF PHOTOENERGY, 2014, 2014
  • [4] Sex- and Site-Specific Normative Data Curves for HR-pQCT
    Burt, Lauren A.
    Liang, Zhiying
    Sajobi, Tolulope T.
    Hanley, David A.
    Boyd, Steven K.
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2016, 31 (11) : 2041 - 2047
  • [5] Synthetic blood and blood products for combat casualty care and beyond
    Cap, Andrew P.
    Cannon, Jeremy W.
    Reade, Michael C.
    [J]. JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2021, 91 (2S) : S26 - S32
  • [6] Influence of optical transmissivity on signal characteristics of photoacoustic guided waves in long cortical bone
    Chen, Honglei
    Xu, Kailiang
    Liu, Xiaoyu
    Li, Ying
    Liu, Zenghua
    Ta, Dean
    [J]. ULTRASONICS, 2022, 126
  • [7] Chin KY, 2013, INT J MED SCI, V10, P857, DOI [10.7150/ijms.6765, 10.7150/ijms.5870]
  • [8] Semi-anthropomorphic photoacoustic breast phantom
    Dantuma, Maura
    van Dommelen, Rianne
    Manohar, Srirang
    [J]. BIOMEDICAL OPTICS EXPRESS, 2019, 10 (11) : 5921 - 5939
  • [9] QUANTITATIVE ULTRASOUND MEASUREMENTS AT THE HEEL: IMPROVEMENT OF SHORT- AND MID-TERM SPEED OF SOUND PRECISION
    Daugschies, Melanie
    Brixen, Kim
    Hermann, Pernille
    Rohde, Kerstin
    Glueer, Claus-Christian
    Barkmann, Reinhard
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (03) : 858 - 870
  • [10] Bone Mineral Loss During Pregnancy: Is Tennis Protective?
    Dimov, Mina
    Khoury, Jane
    Tsang, Reginald
    [J]. JOURNAL OF PHYSICAL ACTIVITY & HEALTH, 2010, 7 (02) : 239 - 245