Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study

被引:8
|
作者
Romero, Marta [1 ]
Herrero-Climent, Mariano [1 ,2 ]
Rios-Carrasco, Blanca [1 ]
Brizuela, Aritza [3 ]
Romero, Manuel Maria [1 ]
Gil, Javier [4 ]
机构
[1] Univ Seville, Sch Dent, Dept Periodontol, C-Avicena S-N, Seville 41009, Spain
[2] Porto Dent Inst, Periodontol Dept, Symmetrya Prothesis, Ave Montevideu 810, P-4150518 Porto, Portugal
[3] Univ Europea Miguel Cervantes, Fac Ciencias Salud, Densia Reserach Grp, C Padre Julio Chevalier 2, Valladolid 47012, Spain
[4] Univ Int Catalunya, Bioengn Inst Technol, Fac Med & Hlth Sci, C Josep Trueta S-N, Sant Cugat Del Valles 08195, Barcelona, Spain
关键词
dental implant; titanium; primary stability; insertion torque; implant stability quotient; RESONANCE FREQUENCY-ANALYSIS; CRESTAL BONE CHANGES; SURFACE-ROUGHNESS; SURGICAL TECHNIQUE; TITANIUM IMPLANTS; FATIGUE; OSSEOINTEGRATION; WETTABILITY; TOPOGRAPHY; GEOMETRY;
D O I
10.3390/jcm12134190
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the placement of dental implants, the primary fixation between the dental implant and the bone is of great importance and corresponds to compressive mechanical fixation that aims to prevent micromovement of the implant. The aim of this research was to determine the role of roughness and the type of dental implant (tissue-level or bone-level) in implant stability, measured using resonance frequency analysis (RFA) and insertion torque (IT). We analyzed 234 titanium dental implants, placed in fresh calf ribs, at the half-tissue level and half-bone level. The implant surface was subjected to grit-blasting treatments with alumina particles of 120, 300, and 600 & mu;m at a projection pressure of 2.5 bar, resulting in three types of roughness. Roughness was determined via optical interferometry. The wettability of the surfaces was also determined. Implant stability was measured using a high-precision torquemeter to obtain IT, and RFA was used to determine the implant stability quotient (ISQ). The results show that rough surfaces with Sa values of 0.5 to 4 & mu;m do not affect the primary stability. However, the type of implant is important; bone-level implants obtained the highest primary stability values. A good correlation between the primary stability values obtained via IT and ISQ was demonstrated. New in vivo studies are necessary to know whether these results can be maintained in the long term.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Calculating ISQ Primary Stability of a Dental Implant through Micromotion
    Pammer, David
    PERIODICA POLYTECHNICA-MECHANICAL ENGINEERING, 2020, 64 (01): : 43 - 50
  • [22] Influence of Bone Quality, Drilling Protocol, Implant Diameter/Length on Primary Stability: An In Vitro Comparative Study on Insertion Torque and Resonance Frequency Analysis
    Farronato, Davide
    Manfredini, Mattia
    Stocchero, Michele
    Caccia, Mattia
    Azzi, Lorenzo
    Farronato, Marco
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (03) : 182 - 189
  • [23] Influence of Clinical Parameters on the Primary Stability of a Tapered Dental Implant: A Retrospective Analysis
    Blume, Oliver
    Wildenhof, Jan
    Otto, Sven
    Probst, Florian A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (04) : 762 - 770
  • [24] The effects of implant design, bone quality, and insertion process on primary stability of dental implants: An in-vitro study
    Rismanchian M.
    Afshari M.
    Afshari, Mojtaba (Afshari.m1989@gmail.com), 1600, Inderscience Publishers (34): : 319 - 333
  • [25] Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design
    Baldi, Domenico
    Lombardi, Teresa
    Colombo, Jacopo
    Cervino, Gabriele
    Perinetti, Giuseppe
    Di Lenarda, Roberto
    Stacchi, Claudio
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [26] ASSESSMENT OF IN VITRO DENTAL IMPLANT PRIMARY STABILITY USING AN ULTRASONIC METHOD
    Vayron, Romain
    Mathieu, Vincent
    Michel, Adrien
    Haiat, Guillaume
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (12) : 2885 - 2894
  • [27] Reliability of the Osstell Implant Stability Quotient and Penguin Resonance Frequency Analysis to Evaluate Implant Stability
    Buyukguclu, Gul
    Ozkurt-Kayahan, Zeynep
    Kazazoglu, Ender
    IMPLANT DENTISTRY, 2018, 27 (04) : 429 - 433
  • [28] Primary stability, insertion torque and bone density of cylindric implant ad modum Branemark: Is there a relationship? An in vitro study
    Trisi, Paolo
    De Benedittis, Simona
    Perfetti, Giorgio
    Berardi, Davide
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (05) : 567 - 570
  • [29] ULTRASONIC EVALUATION OF DENTAL IMPLANT BIOMECHANICAL STABILITY: AN IN VITRO STUDY
    Mathieu, Vincent
    Anagnostou, Fani
    Soffer, Emmanuel
    Haiat, Guillaume
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (02) : 262 - 270
  • [30] Effect of Different Crown Removing Procedures on the Implant Stability Quotient and Removal Torque Values of Dental Implants
    Akin, Hakan
    Unal, Yasemen
    Yilmazer, Kaan
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2021, 11 (02): : 314 - +