Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study

被引:8
|
作者
Romero, Marta [1 ]
Herrero-Climent, Mariano [1 ,2 ]
Rios-Carrasco, Blanca [1 ]
Brizuela, Aritza [3 ]
Romero, Manuel Maria [1 ]
Gil, Javier [4 ]
机构
[1] Univ Seville, Sch Dent, Dept Periodontol, C-Avicena S-N, Seville 41009, Spain
[2] Porto Dent Inst, Periodontol Dept, Symmetrya Prothesis, Ave Montevideu 810, P-4150518 Porto, Portugal
[3] Univ Europea Miguel Cervantes, Fac Ciencias Salud, Densia Reserach Grp, C Padre Julio Chevalier 2, Valladolid 47012, Spain
[4] Univ Int Catalunya, Bioengn Inst Technol, Fac Med & Hlth Sci, C Josep Trueta S-N, Sant Cugat Del Valles 08195, Barcelona, Spain
关键词
dental implant; titanium; primary stability; insertion torque; implant stability quotient; RESONANCE FREQUENCY-ANALYSIS; CRESTAL BONE CHANGES; SURFACE-ROUGHNESS; SURGICAL TECHNIQUE; TITANIUM IMPLANTS; FATIGUE; OSSEOINTEGRATION; WETTABILITY; TOPOGRAPHY; GEOMETRY;
D O I
10.3390/jcm12134190
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the placement of dental implants, the primary fixation between the dental implant and the bone is of great importance and corresponds to compressive mechanical fixation that aims to prevent micromovement of the implant. The aim of this research was to determine the role of roughness and the type of dental implant (tissue-level or bone-level) in implant stability, measured using resonance frequency analysis (RFA) and insertion torque (IT). We analyzed 234 titanium dental implants, placed in fresh calf ribs, at the half-tissue level and half-bone level. The implant surface was subjected to grit-blasting treatments with alumina particles of 120, 300, and 600 & mu;m at a projection pressure of 2.5 bar, resulting in three types of roughness. Roughness was determined via optical interferometry. The wettability of the surfaces was also determined. Implant stability was measured using a high-precision torquemeter to obtain IT, and RFA was used to determine the implant stability quotient (ISQ). The results show that rough surfaces with Sa values of 0.5 to 4 & mu;m do not affect the primary stability. However, the type of implant is important; bone-level implants obtained the highest primary stability values. A good correlation between the primary stability values obtained via IT and ISQ was demonstrated. New in vivo studies are necessary to know whether these results can be maintained in the long term.
引用
收藏
页数:14
相关论文
共 50 条
  • [11] Development of a New Implant Primary Stability Parameter: Insertion Torque Revisited
    Degidi, Marco
    Daprile, Giuseppe
    Piattelli, Adriano
    Iezzi, Giovanna
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (05) : 637 - 644
  • [12] Effect of Implant Length and Insertion Depth on Primary Stability of Short Dental Implant
    Wu, Hsiang-Chun
    Huang, Heng-Li
    Fuh, Lih Jyh
    Tsai, Ming Tzu
    Hsu, Jui-Ting
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (01) : 62 - 70
  • [13] The Influence of the Implant Macrogeometry on Insertion Torque, Removal Torque, and Periotest Implant Primary Stability: A Mechanical Simulation on High-Density Artificial Bone
    Tumedei, Margherita
    Petrini, Morena
    Pietropaoli, Davide
    Cipollina, Alessandro
    La Torre, Castrenze
    Di Carmine, Maria Stella
    Piattelli, Adriano
    Iezzi, Giovanna
    SYMMETRY-BASEL, 2021, 13 (05):
  • [14] Evaluation of the insertion torque, implant stability quotient and drilled hole quality for different drill design: an invitro Investigation
    Alexandre Gehrke, Sergio
    Calvo Guirado, Jose Luis
    Bettach, Raphael
    Del Fabbro, Massimo
    Perez-Albacete Martinez, Carlos
    Shibli, Jamil Awad
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (06) : 656 - 662
  • [15] The relationship between implant stability quotient values and implant insertion variables: a clinical study
    Park, K-J
    Kwon, J-Y
    Kim, S-K
    Heo, S-J
    Koak, J-Y
    Lee, J-H
    Lee, S-J
    Kim, T-H
    Kim, M-J
    JOURNAL OF ORAL REHABILITATION, 2012, 39 (02) : 151 - 159
  • [16] Analyzing the Influence of a New Dental Implant Design on Primary Stability
    da Costa Valente, Mariana Lima
    de Castro, Denise Tornavoi
    Shimano, Antonio Carlos
    Lepri, Cesar Penazzo
    dos Reis, Andrea Candido
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) : 168 - 173
  • [17] Examination of Factor to Influence Dental Implant Stability Quotient Change
    Matsumoto, Keisuke
    Inoue, Kazuya
    Imagawa, Naoko
    Nakajima, Yoichiro
    Nakano, Hiroyuki
    Ueno, Takaaki
    JOURNAL OF HARD TISSUE BIOLOGY, 2020, 29 (02) : 131 - 134
  • [18] A simple mathematical model for the resonance frequency analysis of dental implant stability: Implant clamping quotient
    Argatov, Ivan
    Iantchenko, Alexei
    MECHANICS RESEARCH COMMUNICATIONS, 2019, 95 : 67 - 70
  • [19] Insertion torque/time integral as a measure of primary implant stability
    Grobecker-Karl, Tanja
    Karl, Matthias
    Steiner, Constanze
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2020, 65 (06): : 729 - 733
  • [20] Insertion Torque Value and Implant Stability Quotient: Separate Evaluation and Correlation for Different Clinical Parameters
    Ferreira, Jose Joaquim Da Rocha
    Machado, Luis Filipe Meira
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 812 - 822