Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study

被引:12
作者
Romero, Marta [1 ]
Herrero-Climent, Mariano [1 ,2 ]
Rios-Carrasco, Blanca [1 ]
Brizuela, Aritza [3 ]
Romero, Manuel Maria [1 ]
Gil, Javier [4 ]
机构
[1] Univ Seville, Sch Dent, Dept Periodontol, C-Avicena S-N, Seville 41009, Spain
[2] Porto Dent Inst, Periodontol Dept, Symmetrya Prothesis, Ave Montevideu 810, P-4150518 Porto, Portugal
[3] Univ Europea Miguel Cervantes, Fac Ciencias Salud, Densia Reserach Grp, C Padre Julio Chevalier 2, Valladolid 47012, Spain
[4] Univ Int Catalunya, Bioengn Inst Technol, Fac Med & Hlth Sci, C Josep Trueta S-N, Sant Cugat Del Valles 08195, Barcelona, Spain
关键词
dental implant; titanium; primary stability; insertion torque; implant stability quotient; RESONANCE FREQUENCY-ANALYSIS; CRESTAL BONE CHANGES; SURFACE-ROUGHNESS; SURGICAL TECHNIQUE; TITANIUM IMPLANTS; FATIGUE; OSSEOINTEGRATION; WETTABILITY; TOPOGRAPHY; GEOMETRY;
D O I
10.3390/jcm12134190
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the placement of dental implants, the primary fixation between the dental implant and the bone is of great importance and corresponds to compressive mechanical fixation that aims to prevent micromovement of the implant. The aim of this research was to determine the role of roughness and the type of dental implant (tissue-level or bone-level) in implant stability, measured using resonance frequency analysis (RFA) and insertion torque (IT). We analyzed 234 titanium dental implants, placed in fresh calf ribs, at the half-tissue level and half-bone level. The implant surface was subjected to grit-blasting treatments with alumina particles of 120, 300, and 600 & mu;m at a projection pressure of 2.5 bar, resulting in three types of roughness. Roughness was determined via optical interferometry. The wettability of the surfaces was also determined. Implant stability was measured using a high-precision torquemeter to obtain IT, and RFA was used to determine the implant stability quotient (ISQ). The results show that rough surfaces with Sa values of 0.5 to 4 & mu;m do not affect the primary stability. However, the type of implant is important; bone-level implants obtained the highest primary stability values. A good correlation between the primary stability values obtained via IT and ISQ was demonstrated. New in vivo studies are necessary to know whether these results can be maintained in the long term.
引用
收藏
页数:14
相关论文
共 60 条
[41]   How frequent does peri-implantitis occur? A systematic review and meta-analysis [J].
Rakic, Mia ;
Galindo-Moreno, Pablo ;
Monje, Alberto ;
Radovanovic, Sandro ;
Wang, Hom-Lay ;
Cochran, David ;
Sculean, Anton ;
Canullo, Luigi .
CLINICAL ORAL INVESTIGATIONS, 2018, 22 (04) :1805-1816
[42]   Effects of barrier membranes on bone resorption and implant stability in onlay bone grafts - An experimental study [J].
Rasmusson, L ;
Meredith, N ;
Kahnberg, KE ;
Sennerby, L .
CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (04) :267-277
[43]   Corrosion Resistance and Titanium Ion Release of Hybrid Dental Implants [J].
Robles, Daniel ;
Brizuela, Aritza ;
Fernandez-Dominguez, Manuel ;
Gil, Javier .
MATERIALS, 2023, 16 (10)
[44]   Influence of a Novel Surface of Bioactive Implants on Osseointegration: A Comparative and Histomorfometric Correlation and Implant Stability Study in Minipigs [J].
Romero-Ruiz, Manuel M. ;
Javier Gil-Mur, Francisco ;
Vicente Rios-Santos, Jose ;
Lazaro-Calvo, Pedro ;
Rios-Carrasco, Blanca ;
Herrero-Climent, Mariano .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2019, 20 (09)
[45]  
Rompen E., 2000, APPL OSSEOINTEGR RES, V1, P18
[46]  
Rupp F, 2011, INT J ORAL MAX IMPL, V26, P1256
[47]  
Ryu HS, 2014, J ADV PROSTHODONT, V6, P547
[48]   Implant stability during initiation and resolution of experimental periimplantitis: An experimental study in the dog [J].
Sennerby, L ;
Persson, LG ;
Berglundh, T ;
Wennerberg, A ;
Lindhe, J .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2005, 7 (03) :136-140
[49]   Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications [J].
Sennerby, Lars ;
Meredith, Neil .
PERIODONTOLOGY 2000, 2008, 47 :51-66
[50]   Implant surface roughness and bone healing: a systematic review [J].
Shalabi, M. M. ;
Gortemaker, A. ;
Van't Hof, M. A. ;
Jansen, J. A. ;
Creugers, N. H. J. .
JOURNAL OF DENTAL RESEARCH, 2006, 85 (06) :496-500