Novel Radiofrequency Balloon Catheter-Impact of Ablation Parameters on Single-Shot Isolation

被引:4
|
作者
My, Ilaria [1 ,5 ]
Bordignon, Stefano [2 ]
Butt, Mahi [1 ]
Rottner, Laura [1 ]
Marc, Lemoine [1 ]
Moser, Fabian [1 ]
Wenzel, Jan -Per [1 ]
Obergassel, Julius [1 ]
Schleberger, Ruben [1 ]
Moser, Julia [1 ]
Dinshaw, Leon [1 ]
Kirchhof, Paulus [1 ,3 ]
Reissmann, Bruno [1 ]
Ouyang, Feifan [1 ]
Chun, Kyoung-Ryul Julian [2 ]
Schmidt, Boris [2 ,4 ]
Rillig, Andreas [1 ]
Metzner, Andreas [1 ]
机构
[1] Univ Heart & Vasc Ctr Hamburg, Dept Cardiol, Hamburg, Germany
[2] Cardioangiol Ctr Bethanien, Frankfurt, Germany
[3] Univ Birmingham, Inst Cardiovasc Sci, Birmingham, England
[4] Univ Klinikum Frankfurt, Med Klin 3, Kardiol, Frankfurt, Germany
[5] Univ Heart & Vasc Ctr Hamburg, Dept Cardiol, Martinistr 52, D-20246 Hamburg, Germany
关键词
Atrial fibrillation; Pulmonary vein isolation; Radiofrequency balloon; Single-shot isolation; PAROXYSMAL ATRIAL-FIBRILLATION; PULMONARY VEIN ISOLATION; CRYOBALLOON;
D O I
10.1253/circj.CJ-23-0220
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A novel multielectrode radiofrequency balloon (RFB) catheter has been released for pulmonary vein isolation (PVI). Methods and Results: In this observational study consecutive patients with drug-refractory paroxysmal or persistent atrial fibrillation (AF) undergoing first-time PVI were enrolled in 2 high-volume ablation centers. All procedures were conducted in conjunction with a 3D-mapping system. Clinical, procedural and ablation parameters were systematically analyzed. 105 patients (58% male; 52% paroxysmal AF, 68 & PLUSMN;11.3 years mean age, left atrial volume index 38.6 & PLUSMN;14.8 mL/m2) were included. 241/412 (58.5%) PVs were suc-cessfully isolated with a single shot (SS), with a time-to-isolation of 11.6 & PLUSMN;8 s. Total number of radiofrequency applications was 892 (mean 2.2/PV), resulting in successful isolation of 408/412 (99%) PVs at the end of the procedure. Mean electrodes' impedance drop was significantly higher in the SS-PVI compared with non-SS applications (21.5 & PLUSMN; 6.6 vs. 18.6 & PLUSMN;6.5 Ohm). Concordantly, higher tem-perature rise was observed in the SS vs. non-SS applications (10.9 & PLUSMN; 4.9 & DEG;C vs. 9.6 & PLUSMN;4.7 & DEG;C).Conclusions: In this multicenter real-world study, mean impedance drop and temperature rise were associated with successful SS-PVI applying the novel RFB catheter. These parameters may help to guide efficient usage of the new RF balloon.
引用
收藏
页码:950 / 956
页数:7
相关论文
共 50 条
  • [1] Acute lesion extension following pulmonary vein isolation with two novel single shot devices: Pulsed field ablation versus multielectrode radiofrequency balloon
    My, Ilaria
    Lemoine, Marc D.
    Butt, Mahi
    Mencke, Celine
    Loeck, Fabian W.
    Obergassel, Julius
    Rottner, Laura
    Wenzel, Jan-Per
    Schleberger, Ruben
    Moser, Julia
    Moser, Fabian
    Kirchhof, Paulus
    Reissmann, Bruno
    Ouyang, Feifan
    Rillig, Andreas
    Metzner, Andreas
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (09) : 1802 - 1807
  • [2] Pulmonary vein isolation with the radiofrequency balloon catheter: a single centre prospective study
    Del Monte, Alvise
    Almorad, Alexandre
    Pannone, Luigi
    Della Rocca, Domenico Giovanni
    Bisignani, Antonio
    Monaco, Cinzia
    Mouram, Sahar
    Ramak, Robbert
    Gauthey, Anais
    Overeinder, Ingrid
    Bala, Gezim
    Sorgente, Antonio
    Stroker, Erwin
    Sieira, Juan
    Brugada, Pedro
    La Meir, Mark
    Chierchia, Gian-Battista
    de Asmundis, Carlo
    EUROPACE, 2023, 25 (03): : 896 - 904
  • [3] Efficacy of pulmonary vein isolation with a novel hot balloon ablation catheter
    Evonich, Rudolph F.
    Nori, David M.
    Haines, David E.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 34 (01) : 29 - 36
  • [4] Initial Result of Antrum Pulmonary Vein Isolation Using the Radiofrequency Hot-Balloon Catheter With Single-Shot Technique
    Yamasaki, Hiro
    Aonuma, Kazutaka
    Shinoda, Yasutoshi
    Komatsu, Yuki
    Masuda, Keita
    Hashimoto, Naoaki
    Sai, Eikou
    Yamagami, Fumi
    Okabe, Yuta
    Tsumagari, Yasuaki
    Hanaki, Yuichi
    Watanabe, Hiroaki
    Machino, Takeshi
    Kuroki, Kenji
    Sekiguchi, Yukio
    Nogami, Akihiko
    Ieda, Masaki
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (03) : 354 - 363
  • [5] Investigating the role of electroanatomical mapping in single-shot pulsed field catheter ablation
    Kariki, Ourania
    Mililis, Panagiotis
    Saplaouras, Athanasios
    Efremidis, Theodoros
    Chatziantoniou, Anastasios
    Panagiotopoulos, Ioannis
    Dragasis, Stylianos
    Letsas, Konstantinos P.
    Efremidis, Michael
    JOURNAL OF ARRHYTHMIA, 2024, 40 (06) : 1374 - 1378
  • [6] 'Single-shot' pulmonary vein isolation using a novel lotos pulsed field ablation catheter: a pre-clinical evaluation of feasibility, safety, and 30-day efficacy
    Pu, Sijia
    Liu, Fangzhou
    Chen, Yuhan
    Luo, Cihua
    Li, Peng
    Chen, Yanlin
    Fu, Lu
    Liu, Huiyi
    Ye, Xingdong
    Wu, Shulin
    Xue, Yumei
    Lin, Weidong
    EUROPACE, 2023, 26 (01):
  • [7] Efficacy of pulmonary vein isolation with a novel hot balloon ablation catheter
    Rudolph F. Evonich
    David M. Nori
    David E. Haines
    Journal of Interventional Cardiac Electrophysiology, 2012, 34 : 29 - 36
  • [8] Lattice-tip catheter for single-shot pulmonary vein isolation with pulsed field ablation
    Yavin, Hagai D.
    Higuchi, Koji
    Younis, Arwa
    Anter, Elad
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (07) : 1741 - 1748
  • [9] Lattice-tip catheter for single-shot pulmonary vein isolation with pulsed field ablation
    Hagai D. Yavin
    Koji Higuchi
    Arwa Younis
    Elad Anter
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 1741 - 1748
  • [10] Preclinical assessment of the feasibility, safety and lesion durability of a novel 'single-shot' pulsed field ablation catheter for pulmonary vein isolation
    Koruth, Jacob
    Kawamura, Iwanari
    Dukkipati, Srinivas R.
    Neuzil, Petr
    Reddy, Vivek Y.
    EUROPACE, 2023, 25 (04): : 1369 - 1378