Failure Analysis of Heat Exchanger Tubes

被引:3
作者
Saffiudeen, Mohamed Fayas [1 ]
Syed, Abdullah [1 ]
Mohammed, Fasil T. [1 ]
机构
[1] Royal Commiss Jubail & Yanbu, Jubail Tech Inst, Dept Mech Skills, Jubail Ind City, Saudi Arabia
关键词
Heat exchanger; Tube inspection; Eddy current testing; Retubing; Maintenance; PMI inspection;
D O I
10.1007/s11668-023-01679-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This research aimed to investigate the causes of tube failures in a shell-and-tube heat exchanger at an oil and gas plant. The shell side of this heat exchanger (reboiler) is used to heat cooling water, while the tube side is used to generate process vapor. The tube material was made of SA 213 TP 317LM (UNS 31725), and tube sheet material was SA 240 TP 317LM (UNS 31725). This heat exchanger had failed its 91 tubes against 2998 tubes after just over 1.8 years in service. Eddy current testing was carried out on 100% of tubes during the turnaround and found 91 tubes with wall thickness loss between 10 and 54%. A failure investigation was carried out on the leaked tubes by pulling one tube and examined for visual examination and a chemical composition test (PMI testing) to see if the material used met the standard specification. The preliminary cause of the tube failure is change in the tube material grade, and the actual tube material is SA 213 TP 304L instead of the required SA 213 TP 317LM. Poor quality control from the inspection department has resulted in the tubes failing to meet the required standards specification of the heat exchanger. As a significant corrective or remedial action, heat exchanger tubes must be changed to SA 213 TP 317LM based on the requirement after performing 100% ECT.
引用
收藏
页码:1259 / 1264
页数:6
相关论文
共 28 条
[1]   Degradation study of heat exchangers [J].
Addepalli, Sri ;
Eiroa, David ;
Lieotrakool, Suphansa ;
Francois, Anne-Laure ;
Guisset, Juliette ;
Sanjaime, David ;
Kazarian, Michele ;
Duda, Julia ;
Roy, Rajkumar ;
Phillips, Paul .
PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON THROUGH-LIFE ENGINEERING SERVICES, 2015, 38 :137-142
[2]   Failure Analysis of Stainless Steel Heat Exchanger Tubes in a Petrochemical Plant [J].
Adnyana, D. N. .
JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2018, 18 (02) :413-422
[3]  
Al-Othmani DS., 2022, J KING ABDULAZIZ U E, V32, P2
[4]   Failure Analysis of a Heat Exchanger Shell [J].
Al-Shahrani, S. ;
Al-Meshari, A. ;
van Zyl, G. N. ;
Ahmad, S. .
JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2013, 13 (01) :20-25
[5]   Review of common failures in heat exchangers - Part I: Mechanical and elevated temperature failures [J].
Ali, Murad ;
Ul-Hamid, Anwar ;
Alhems, Luai M. ;
Saeed, Aamer .
ENGINEERING FAILURE ANALYSIS, 2020, 109
[6]  
[Anonymous], 2021, ASME BPVC SECTION 5
[7]  
[Anonymous], 2021, ASME BPVC SECTION 2
[8]  
[Anonymous], 2021, ASME BPVC SECTION 9
[9]  
[Anonymous], 2022, ASME PCC 2 REPAIR PR
[10]   Failure analysis of AISI 321 tubes of heat exchanger [J].
Corte, J. S. ;
Rebello, J. M. A. ;
Areiza, M. C. L. ;
Tavares, S. S. M. ;
Araujo, M. D. .
ENGINEERING FAILURE ANALYSIS, 2015, 56 :170-176