Quantitative visualization of a radioactive plume with harmonizing gamma-ray imaging spectrometry and real-time atmospheric dispersion simulation based on 3D wind observation

被引:2
|
作者
Nagai, Haruyasu [1 ]
Furuta, Yoshihiro [2 ]
Nakayama, Hiromasa [1 ]
Satoh, Daiki [1 ]
机构
[1] Japan Atom Energy Agcy, Nucl Sci & Engn Ctr, Tokai, Ibaraki, Japan
[2] CLEAR PULSE CO LTD, Engn Dept, Ota Ku, Tokyo, Japan
关键词
Quantitative visualization of radioactive plume; source term; radiation imaging; atmospheric dispersion simulation; wind observation with Doppler lidar; NUCLEAR-POWER-PLANT; SOURCE-TERM ESTIMATION; LARGE-EDDY SIMULATION; TURBULENT-FLOW; COMPTON CAMERA; MODEL; RADIONUCLIDES; DISCHARGE; RELEASE; SENSITIVITY;
D O I
10.1080/00223131.2023.2197445
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To propose a novel monitoring method for the quantitative visualization of 3D distribution of a radioactive plume in the vicinity of release point and source term estimation of released radionuclides, the feasibility of its analysis method is demonstrated by preliminary test. The proposed method is the combination of gamma-ray imaging spectroscopy with the electron tracking Compton camera (ETCC) and real-time high-resolution atmospheric dispersion simulation based on 3D wind observation with Doppler lidar. ETCC can acquire the angle distribution images of direct gamma-ray from a specific radionuclide in a target radioactive plume by quantitatively capturing gamma-ray incidence angles and spectrum distributions. The 3D distribution of each radionuclide in the radioactive plume is inversely reconstructed from direct gamma-ray images of each radionuclide by several ETCCs located around the target by harmonizing with the air concentration distribution pattern of the plume predicted by real-time atmospheric dispersion simulation. A prototype of the analysis method was developed, showing a sufficient performance in several test cases using hypothetical data generated by numerical simulations of atmospheric dispersion and radiation transport. The proposed method is expected to become an innovative monitoring framework for nuclear emergency.
引用
收藏
页码:1345 / 1360
页数:16
相关论文
共 7 条
  • [1] Handheld real-time volumetric 3-D gamma-ray imaging
    Haefner, Andrew
    Barnowski, Ross
    Luke, Paul
    Amman, Mark
    Vetter, Kai
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 857 : 42 - 49
  • [2] Simulation code for estimating external gamma-ray doses from a radioactive plume and contaminated ground using a local-scale atmospheric dispersion model
    Satoh, Daiki
    Nakayama, Hiromasa
    Furuta, Takuya
    Yoshihiro, Tamotsu
    Sakamoto, Kensaku
    PLOS ONE, 2021, 16 (01):
  • [3] Real-time 3D visualization of forest fire spread based on tree morphology and finite state machine
    You, Jiawei
    Huai, Yongjian
    Nie, Xiaoying
    Chen, Yuanyuan
    COMPUTERS & GRAPHICS-UK, 2022, 103 : 109 - 120
  • [4] 3D tumor localization through real-time volumetric x-ray imaging for lung cancer radiotherapy
    Li, Ruijiang
    Lewis, John H.
    Jia, Xun
    Gu, Xuejun
    Folkerts, Michael
    Men, Chunhua
    Song, William Y.
    Jiang, Steve B.
    MEDICAL PHYSICS, 2011, 38 (05) : 2783 - 2794
  • [5] Web-based real-time visualization of large-scale weather radar data using 3D tiles
    Lu, Mingyue
    Wang, Xinhao
    Liu, Xintao
    Chen, Min
    Bi, Shuoben
    Zhang, Yadong
    Lao, Tengfei
    TRANSACTIONS IN GIS, 2021, 25 (01) : 25 - 43
  • [6] Real-time volumetric image reconstruction and 3D tumor localization based on a single x-ray projection image for lung cancer radiotherapy
    Li, Ruijiang
    Jia, Xun
    Lewis, John H.
    Gu, Xuejun
    Folkerts, Michael
    Men, Chunhua
    Jiang, Steve B.
    MEDICAL PHYSICS, 2010, 37 (06) : 2822 - 2826
  • [7] Concentration-aware real-time 3D reconstruction of leaking gas clouds based on two-view bandpass optical gas imaging
    Cai, Lijing
    Shi, Zhan
    Zi, Chongde
    Chen, Linsen
    Cao, Xun
    OPTICS EXPRESS, 2025, 33 (03): : 5310 - 5327