Patient-centred care with self-compression mammography in clinical practice: a randomized trial compared to standard compression

被引:2
|
作者
Iotti, Valentina [1 ]
Rossi, Paolo Giorgi [2 ]
Canovi, Laura [1 ]
Guberti, Monica [1 ]
Nitrosi, Andrea [3 ]
Lippolis, Davide Giosue [3 ]
Marchesi, Vanessa [1 ]
Besutti, Giulia [1 ]
Ottone, Marta [2 ]
Vacondio, Rita [1 ]
Pattacini, Pierpaolo [1 ]
机构
[1] Azienda Unita Sanitaria Locale IRCCS Reggio Emili, Radiol Unit, Via Amendola 2, I-42122 Reggio Emilia, Italy
[2] Azienda Unita Sanitaria Locale IRCCS Reggio Emili, Epidemiol Unit, Via Amendola 2, I-42122 Reggio Emilia, Italy
[3] Azienda Unita Sanitaria Locale IRCCS Reggio Emili, Med Phys Unit, Via Amendola 2, I-42122 Reggio Emilia, Italy
关键词
Breast cancer; Mammography; Self-care; Pain; Radiation dosage; PAIN; IMPACT; FORCE;
D O I
10.1007/s00330-022-09002-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To test the efficacy of self- compared to radiographer-led compression to reduce the average glandular dose without affecting image quality and compliance to follow-up mammography. Materials and methods Women presenting for mammography for breast cancer follow-up, symptoms, opportunistic screening, or familial risk were asked to participate and, if willing, were randomized to self-compression or radiographer-led compression. Image quality was assessed blindly by two independent radiologists and two radiographers. Pain and discomfort were measured immediately after mammography and their recall was asked when the women participated in the follow-up mammogram, 1 or 2 years later. Results In total, 495 women (mean age 57 years +/-14) were enrolled, 245 in the self-compression and 250 radiographer-compression arms. Image quality was similar in the two arms (radiologists' judgement p = 0.90; radiographers' judgement p = 0.32). A stronger compression force was reached in the self- than in the radiographer-arm (114.5 vs. 10.25 daN, p < .001), with a 1.7-mm reduction in thickness (p = .14), and almost no impact on dose per exam (1.90 vs. 1.93 mGy, p = .47). Moderate/severe discomfort was reported by 7.8% vs 9.6% (p = .77) and median pain score was 4.0 in both arms (p = .55). Median execution time was 1 min longer with self-compression (10.0 vs. 9.1 min, p < 0.001). No effect on subsequent mammography was detectable (p = 0.47). Conclusion Self-compression achieved stronger compression of the breast, with comparable image quality, but did not substantially reduce glandular dose. The proportion of women who attended follow-up mammography was also similar in the two groups.
引用
收藏
页码:450 / 460
页数:11
相关论文
共 13 条
  • [1] Patient-centred care with self-compression mammography in clinical practice: a randomized trial compared to standard compression
    Valentina Iotti
    Paolo Giorgi Rossi
    Laura Canovi
    Monica Guberti
    Andrea Nitrosi
    Davide Giosuè Lippolis
    Vanessa Marchesi
    Giulia Besutti
    Marta Ottone
    Rita Vacondio
    Pierpaolo Pattacini
    European Radiology, 2023, 33 : 450 - 460
  • [2] Comparison of technical parameters and women's experience between self-compression and standard compression modes in mammography screening: a single-blind randomized clinical trial
    Arenas, Natalia
    Alcantara, Rodrigo
    Posso, Margarita
    Louro, Javier
    Perez-Leon, Daniela
    Ejarque, Belen
    Arranz, Monica
    Maiques, Jose
    Castells, Xavier
    Macia, Francesc
    Roman, Marta
    Rodriguez-Arana, Ana
    EUROPEAN RADIOLOGY, 2022, 32 (11) : 7480 - 7487
  • [3] Breast compression parameters among women screened with standard digital mammography and digital breast tomosynthesis in a randomized controlled trial
    Waade, Gunvor Gipling
    Holen, Asne
    Sebuodegard, Sofie
    Aase, Hildegunn
    Pedersen, Kristin
    Hanestad, Berit
    Hofvind, Solveig
    ACTA RADIOLOGICA, 2020, 61 (03) : 321 - 330
  • [4] Does the patient-assisted compression mode affect the mammography quality? A within-woman randomized controlled trial
    Perez-Leon, Daniela
    Posso, Margarita
    Louro, Javier
    Ejarque, Belen
    Arranz, Monica
    Arenas, Natalia
    Maiques, Jose
    Martinez, Juan
    Macia, Francesc
    Roman, Marta
    Rodriguez-Arana, Ana
    Castells, Xavier
    Alcantara, Rodrigo
    EUROPEAN RADIOLOGY, 2022, 32 (11) : 7470 - 7479
  • [5] Optimising recovery after perineal trauma: Implementation of an evidence-based patient-centred care and clinical practice guideline
    Khajehei, Marjan
    Swain, Julie
    King, Jennifer
    Compton, Collette
    Wei, Wandi
    Mcgee, Therese
    Chua, Seng Chai
    Gidaszewski, Beata
    WOMEN AND BIRTH, 2024, 37 (03)
  • [6] Does the patient-assisted compression mode affect the mammography quality? A within-woman randomized controlled trial
    Daniela Perez-Leon
    Margarita Posso
    Javier Louro
    Belén Ejarque
    Mónica Arranz
    Natalia Arenas
    Jose Maiques
    Juan Martínez
    Francesc Maciá
    Marta Román
    Ana Rodríguez-Arana
    Xavier Castells
    Rodrigo Alcántara
    European Radiology, 2022, 32 : 7470 - 7479
  • [7] Effect of a patient-centred deprescribing procedure in older multimorbid patients in Swiss primary care-A cluster-randomised clinical trial
    Zechmann, Stefan
    Senn, Oliver
    Valeri, Fabio
    Essig, Stefan
    Merlo, Christoph
    Rosemann, Thomas
    Neuner-Jehle, Stefan
    BMC GERIATRICS, 2020, 20 (01)
  • [8] Effectiveness of a precast adjustable compression system compared to multilayered compression bandages in the treatment of breast cancer-related lymphoedema: a randomized, single-blind clinical trial
    Pujol-Blaya, Vicenta
    Salinas-Huertas, Sira
    Luisa Catasus, M.
    Pascual, Teresa
    Belmonte, Roser
    CLINICAL REHABILITATION, 2019, 33 (04) : 631 - 641
  • [9] Patient-centred home-based management of heart failure Findings from a randomised clinical trial evaluating a tablet computer for self-care, quality of life and effects on knowledge
    Hagglund, Ewa
    Lynga, Patrik
    Frie, Filippa
    Ullman, Bengt
    Persson, Hans
    Melin, Michael
    Hagerman, Inger
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2015, 49 (04) : 193 - 199
  • [10] The effect of virtual reality (VR) glasses and therapeutic touch (TT) on pain, anxiety, and patient satisfaction during intrauterine insemination (IUI) compared to standard care: a single-blind, randomized controlled trial
    Bal, Sumeyye
    Karakaya, Nese
    Koc, Emine
    Guven, Davut
    BMC PREGNANCY AND CHILDBIRTH, 2025, 25 (01)