Determination of trace fluoroquinolones in honey and milk based on cyclodextrin modified magnetic metal-organic frameworks solid phase extraction coupled with ultra-high performance liquid chromatography

被引:15
作者
Sun, Yangkun [1 ]
Kuang, Jingjing [1 ]
Cheng, Yongzhe [1 ]
Lin, Chuhui [1 ]
Zhang, Hongyang [1 ]
Zhang, Min [2 ]
Ning, Fanghong [3 ]
Hu, Ping [1 ]
机构
[1] East China Univ Sci & Technol, Sch Chem & Mol Engn, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China
[2] East China Univ Sci & Technol, Shanghai Frontiers Sci Ctr Optogenet Tech Cell Met, Sch Pharm, Shanghai 200237, Peoples R China
[3] East China Univ Sci & Technol, Sch Biotechnol, Shanghai 200237, Peoples R China
关键词
Fluoroquinolone; Magnetic solid phase extraction; Ultra-high performance liquid chromatography; MOLECULARLY IMPRINTED POLYMERS; WATER; SAMPLES;
D O I
10.1016/j.chroma.2023.464521
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Long-term intake of animal-derived foods with excessive fluoroquinolones (FQs) will cause damage to human health, so it is critical to establish a feasible approach for sensitive and rapid monitoring of FQs residues. In this study, a new cyclodextrin modified magnetic metal-organic frameworks (Fe3O4@UiO-66-CD) was successfully synthesized by amidation reaction and applied to magnetic solid phase extraction (MSPE) for FQs analysis. The adsorption behavior of Fe3O4@UiO-66-CD was consistent with the pseudo-second-order kinetics and Freundlich isothermal adsorption model, which indicated that the designed material had various interactions on FQs, such as host-guest interaction and 7C-7C interaction. The parameters of MSPE were optimized and the determination method of norfloxacin, enrofloxacin, lomefloxacin and gatifloxacin was established by using MSPE combined with ultra-high performance liquid chromatography (UHPLC) and fluorescence detector (FLD). The method validation results displayed that the detection limits were 0.02-0.09 ng/mL, and the RSDs of intra-day and inter -day precision were less than 4.1 and 6.4 %, respectively. In the target FQs analysis of real honey and milk samples, the recoveries at different fortified concentrations were in the ranges of 88.4 % to 108.6 % with RSD <= 5.7 %. The results showed that the proposed method was sensitive, accurate and reliable for the determination of trace FQs in animal-derived foods.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Curcumin loaded magnetic graphene oxide solid-phase extraction for the determination of parabens in toothpaste and mouthwash coupled with high performance liquid chromatography
    Razavi, Nourolhoda
    Es'haghi, Zarrin
    MICROCHEMICAL JOURNAL, 2019, 148 : 616 - 625
  • [42] Determination of patulin in apple juice using magnetic solid-phase extraction coupled with high-performance liquid chromatography
    Yu, Youwei
    Fan, Zhefeng
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2017, 34 (02): : 273 - 281
  • [43] Core-shell magnetic porous organic polymer for magnetic solid-phase extraction of fluoroquinolone antibiotics in honey samples followed by high-performance liquid chromatography with fluorescence detection
    Tian, Cong
    Ren, Xue
    He, Man
    Chen, Beibei
    Hu, Bin
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (04) : 874 - 882
  • [44] Determination of chlorophenoxy acid herbicides by using a zirconium-based metal-organic framework as special sorbent for dispersive micro-solid-phase extraction and high-performance liquid chromatography
    Xia, Lian
    Liu, Lijie
    Xu, Xianli
    Zhu, Fenfen
    Wang, Xiuli
    Zhang, Keyun
    Yang, Xuncheng
    You, Jinmao
    NEW JOURNAL OF CHEMISTRY, 2017, 41 (06) : 2241 - 2248
  • [45] Direct determination of ultra-trace polycyclic aromatic hydrocarbons in water by liquid chromatography coupled with online solid phase extraction
    Wang Chao
    Huang Zhaozhang
    Xing Zhanlei
    Chen Ye
    Yu Jianzhao
    Liu Fang
    Yuan Mao
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2019, 37 (02) : 239 - 245
  • [46] Multiresidue analysis of organic pollutants by in-tube solid phase microextraction coupled to ultra-high performance liquid chromatography-electrospray-tandem mass spectrometry
    Masia, A.
    Moliner-Martinez, Y.
    Munoz-Ortuno, M.
    Pico, Y.
    Campins-Falco, P.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1306 : 1 - 11
  • [47] Determination of Butachlor and Fipronil in Liquid Milk Using Ionic Liquid Dispersive Liquid-Liquid Microextraction Coupled with Ultra-High Performance Liquid Chromatography
    Gao, Yuling
    Liang, Xilong
    Sun, Peng
    Guo, Yongxia
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (11) : 1430 - 1434
  • [48] Determination of diethylstilbestrol in seawater by molecularly imprinted solid-phase extraction coupled with high-performance liquid chromatography
    He, Xiuping
    Mei, Xiaoqi
    Wang, Jiangtao
    Lian, Ziru
    Tan, Liju
    Wu, Wei
    MARINE POLLUTION BULLETIN, 2016, 102 (01) : 142 - 147
  • [49] Simultaneous enrichment and determination of cadmium and mercury ions using magnetic PAMAM dendrimers as the adsorbents for magnetic solid phase extraction coupled with high performance liquid chromatography
    Yuan, Yongyong
    Wu, Yalin
    Wang, Hongyuan
    Tong, Yayan
    Sheng, Xueying
    Sun, Yi
    Zhou, Xianqi
    Zhou, Qingxiang
    JOURNAL OF HAZARDOUS MATERIALS, 2020, 386
  • [50] Determination of diuretics in human urine using HPLC coupled with magnetic solid-phase extraction based on a metal-organic framework
    Liu, Meng
    Lv, Bingqiang
    Jiang, Hailong
    Yuan, Pei
    Zhu, Huan
    Gao, Binghong
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (09)