Determination of trace fluoroquinolones in honey and milk based on cyclodextrin modified magnetic metal-organic frameworks solid phase extraction coupled with ultra-high performance liquid chromatography

被引:15
作者
Sun, Yangkun [1 ]
Kuang, Jingjing [1 ]
Cheng, Yongzhe [1 ]
Lin, Chuhui [1 ]
Zhang, Hongyang [1 ]
Zhang, Min [2 ]
Ning, Fanghong [3 ]
Hu, Ping [1 ]
机构
[1] East China Univ Sci & Technol, Sch Chem & Mol Engn, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China
[2] East China Univ Sci & Technol, Shanghai Frontiers Sci Ctr Optogenet Tech Cell Met, Sch Pharm, Shanghai 200237, Peoples R China
[3] East China Univ Sci & Technol, Sch Biotechnol, Shanghai 200237, Peoples R China
关键词
Fluoroquinolone; Magnetic solid phase extraction; Ultra-high performance liquid chromatography; MOLECULARLY IMPRINTED POLYMERS; WATER; SAMPLES;
D O I
10.1016/j.chroma.2023.464521
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Long-term intake of animal-derived foods with excessive fluoroquinolones (FQs) will cause damage to human health, so it is critical to establish a feasible approach for sensitive and rapid monitoring of FQs residues. In this study, a new cyclodextrin modified magnetic metal-organic frameworks (Fe3O4@UiO-66-CD) was successfully synthesized by amidation reaction and applied to magnetic solid phase extraction (MSPE) for FQs analysis. The adsorption behavior of Fe3O4@UiO-66-CD was consistent with the pseudo-second-order kinetics and Freundlich isothermal adsorption model, which indicated that the designed material had various interactions on FQs, such as host-guest interaction and 7C-7C interaction. The parameters of MSPE were optimized and the determination method of norfloxacin, enrofloxacin, lomefloxacin and gatifloxacin was established by using MSPE combined with ultra-high performance liquid chromatography (UHPLC) and fluorescence detector (FLD). The method validation results displayed that the detection limits were 0.02-0.09 ng/mL, and the RSDs of intra-day and inter -day precision were less than 4.1 and 6.4 %, respectively. In the target FQs analysis of real honey and milk samples, the recoveries at different fortified concentrations were in the ranges of 88.4 % to 108.6 % with RSD <= 5.7 %. The results showed that the proposed method was sensitive, accurate and reliable for the determination of trace FQs in animal-derived foods.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Determination of organic ultraviolet filters in environmental waters by magnetic solid phase extraction-high performance liquid chromatography
    Liu Cheng
    Chen Lei
    Ye Ziwen
    Huang Xiaojia
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2019, 37 (08) : 918 - 923
  • [32] Liquid-solid extraction coupled with magnetic solid-phase extraction for determination of pyrethroid residues in vegetable samples by ultra fast liquid chromatography
    Jiang, Chunzhu
    Sun, Ying
    Yu, Xi
    Gao, Yan
    Zhang, Lei
    Wang, Yuanpeng
    Zhang, Hanqi
    Song, Daqian
    TALANTA, 2013, 114 : 167 - 175
  • [33] Rapid and Selective Determination of Trace Benzimidazole Fungicides in Fruit Juices by Magnetic Solid-Phase Extraction Coupled with High-Performance Liquid Chromatography-Fluorescence Detection
    Deng, Xiaojuan
    Chen, Xiaoping
    Lin, Kui
    Ding, Guosheng
    Yao, Pei
    FOOD ANALYTICAL METHODS, 2013, 6 (06) : 1576 - 1582
  • [34] Magnetic Solid-Phase Extraction and Ionic Liquid Dispersive Liquid-Liquid Microextraction Coupled with High-Performance Liquid Chromatography for the Determination of Hexachlorophene in Cosmetics
    Liu, Ruiqi
    Liu, Ye
    Cheng, Chunsheng
    Yang, Yaling
    CHROMATOGRAPHIA, 2017, 80 (05) : 783 - 791
  • [35] Enrichment of Trace Selenium in Water Based on Metal-Organic Framework Materials and Reversed-Phase Ultra-High-Performance Liquid Chromatography-Diode Array Determination
    Cai, Hanqing
    Guo, Hongmei
    Jing, Hanlu
    Wen, Pingping
    Wu, Qiuying
    Li, Yang
    Suo, Zhirong
    Zhang, Jian
    SEPARATIONS, 2025, 12 (03)
  • [36] Magnetic Metal-Organic Framework/Graphene Oxide-Based Solid-Phase Extraction Combined with Spectrofluorimetry for the Determination of Enrofloxacin in Milk Sample
    Li, Zhaoqian
    Qi, Mengyu
    Tu, Chunyan
    Wang, Weiping
    Chen, Jianrong
    Wang, Ai-Jun
    FOOD ANALYTICAL METHODS, 2017, 10 (12) : 4094 - 4103
  • [37] Determination of type A trichothecenes in coix seed by magnetic solid-phase extraction based on magnetic multi-walled carbon nanotubes coupled with ultra-high performance liquid chromatography-tandem mass spectrometry
    Maofeng Dong
    Wenshuai Si
    Weimin Wang
    Bing Bai
    Dongxia Nie
    Weiguo Song
    Zhihui Zhao
    Yirong Guo
    Zheng Han
    Analytical and Bioanalytical Chemistry, 2016, 408 : 6823 - 6831
  • [38] Zeolitic imidazolate framework-8 modified magnetic halloysite nanotube-based solid phase extraction for the analysis of carbamate pesticides by ultra-high performance liquid chromatography tandem mass spectrometry
    Shi, Zhihong
    Tian, Yuehong
    Liu, Junjie
    Wu, Wenwen
    Gao, Sifan
    Zhang, Hongyi
    ANALYTICAL METHODS, 2022, 14 (45) : 4659 - 4668
  • [39] Fast separation and determination of erythromycin with magnetic imprinted solid extraction coupled with high performance liquid chromatography
    Rao, Wei
    Cai, Rong
    Zhang, Zhaohui
    Yin, Yuli
    Long, Fang
    Fu, Xinxi
    RSC ADVANCES, 2014, 4 (36): : 18503 - 18511
  • [40] Determination of hexanal and heptanal in human urine using magnetic solid phase extraction coupled with in-situ derivatization by high performance liquid chromatography
    Liu, Jiu-Feng
    Yuan, Bi-Feng
    Feng, Yu-Qi
    TALANTA, 2015, 136 : 54 - 59