Virtual pretreatment patient-specific quality assurance of volumetric modulated arc therapy using deep learning

被引:7
作者
Yoganathan, S. A. [1 ]
Ahmed, Sharib [1 ]
Paloor, Satheesh [1 ]
Torfeh, Tarraf [1 ]
Aouadi, Souha [1 ]
Al-Hammadi, Noora [1 ]
Hammoud, Rabih [1 ]
机构
[1] Hamad Med Corp, Natl Ctr Canc Care & Res NCCCR, Dept Radiat Oncol, POB 3050, Doha, Qatar
关键词
automatic; deep learning; gamma evaluation; QA; VMAT; ERROR-DETECTION; IMRT QA; RADIOMIC ANALYSIS; CLASSIFICATION; PREDICTION;
D O I
10.1002/mp.16567
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundAutomatic patient-specific quality assurance (PSQA) is recently explored using artificial intelligence approaches, and several studies reported the development of machine learning models for predicting the gamma pass rate (GPR) index only. PurposeTo develop a novel deep learning approach using a generative adversarial network (GAN) to predict the synthetic measured fluence. Methods and materialsA novel training method called "dual training," which involves the training of the encoder and decoder separately, was proposed and evaluated for cycle GAN (cycle-GAN) and conditional GAN (c-GAN). A total of 164 VMAT treatment plans, including 344 arcs (training data: 262, validation data: 30, and testing data: 52) from various treatment sites, were selected for prediction model development. For each patient, portal-dose-image-prediction fluence from TPS was used as input, and measured fluence from EPID was used as output/response for model training. Predicted GPR was derived by comparing the TPS fluence with the synthetic measured fluence generated by the DL models using gamma evaluation of criteria 2%/2 mm. The performance of dual training was compared against the traditional single-training approach. In addition, we also developed a separate classification model specifically designed to detect automatically three types of errors (rotational, translational, and MU-scale) in the synthetic EPID-measured fluence. ResultsOverall, the dual training improved the prediction accuracy of both cycle-GAN and c-GAN. Predicted GPR results of single training were within 3% for 71.2% and 78.8% of test cases for cycle-GAN and c-GAN, respectively. Moreover, similar results for dual training were 82.7% and 88.5% for cycle-GAN and c-GAN, respectively. The error detection model showed high classification accuracy (>98%) for detecting errors related to rotational and translational errors. However, it struggled to differentiate the fluences with "MU scale error" from "error-free" fluences. ConclusionWe developed a method to automatically generate the synthetic measured fluence and identify errors within them. The proposed dual training improved the PSQA prediction accuracy of both the GAN models, with c-GAN demonstrating superior performance over the cycle-GAN. Our results indicate that the c-GAN with dual training approach combined with error detection model, can accurately generate the synthetic measured fluence for VMAT PSQA and identify the errors. This approach has the potential to pave the way for virtual patient-specific QA of VMAT treatments.
引用
收藏
页码:7891 / 7903
页数:13
相关论文
共 49 条
[41]   Implementing RapidArc into clinical routine: A comprehensive program from machine QA to TPS validation and patient QA [J].
Van Esch, Ann ;
Huyskens, Dominique P. ;
Behrens, Claus F. ;
Samsoe, Eva ;
Sjolin, Maria ;
Bjelkengren, Ulf ;
Sjostrom, David ;
Clermont, Christian ;
Hambach, Lionel ;
Sergent, Francois .
MEDICAL PHYSICS, 2011, 38 (09) :5146-5166
[42]  
Wall Phillip D. H., 2020, Informatics in Medicine Unlocked, V18, P190, DOI 10.1016/j.imu.2020.100292
[43]  
Wall PDH, 2022, INT J RADIAT ONCOL, V113, P1091, DOI [10.1016/j.ijrobp.2021.04.040, 10.1016/j.ijrobp.2022.04.040]
[44]   Quality assurance-based optimization (QAO): Towards improving patient-specific quality assurance in volumetric modulated arc therapy plans using machine learning [J].
Wall, Phillip D. H. ;
Fontenot, Jonas D. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 87 :136-143
[45]   Error Detection in Intensity-Modulated Radiation Therapy Quality Assurance Using Radiomic Analysis of Gamma Distributions [J].
Wootton, Landon S. ;
Nyflot, Matthew J. ;
Chaovalitwongse, W. Art ;
Ford, Eric .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (01) :219-228
[46]   Artificial intelligence will soon change the landscape of medical physics research and practice [J].
Xing, Lei ;
Krupinski, Elizabeth A. ;
Cai, Jing .
MEDICAL PHYSICS, 2018, 45 (05) :1791-1793
[47]   Deep reinforcement learning and its applications in medical imaging and radiation therapy: a survey [J].
Xu, Lanyu ;
Zhu, Simeng ;
Wen, Ning .
PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (22)
[48]   Commissioning and clinical implementation of an Autoencoder based Classification-Regression model for VMAT patient-specific QA in a multi-institution scenario [J].
Yang, Ruijie ;
Yang, Xueying ;
Wang, Le ;
Li, Dingjie ;
Guo, Yuexin ;
Li, Ying ;
Guan, Yumin ;
Wu, Xiangyang ;
Xu, Shouping ;
Zhang, Shuming ;
Chan, Maria F. ;
Geng, Lisheng ;
Sui, Jing .
RADIOTHERAPY AND ONCOLOGY, 2021, 161 :230-240
[49]   Uncertainty-guided man-machine integrated patient-specific quality assurance [J].
Yang, Xiaoyu ;
Li, Shuzhou ;
Shao, Qigang ;
Cao, Ying ;
Yang, Zhen ;
Zhao, Yu-qian .
RADIOTHERAPY AND ONCOLOGY, 2022, 173 :1-9