Impact of Implant Diameter on the Early Survival Rate of Dental Implants in the Saudi Population: A One-Year Retrospective Study

被引:0
|
作者
Mously, Eihab A. [1 ]
机构
[1] Taibah Univ, Prevent Dent Sci, Coll Dent, Madina, Saudi Arabia
关键词
implant size; early implant success rate; early implant survival rate; implant diameter; dental implant; LENGTH; PLACEMENT; IMMEDIATE; FAILURES;
D O I
10.7759/cureus.37765
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionThe use of dental implants provides a revolutionary solution to the problem of missing teeth in the oral cavity. The aim of this study was to assess the early implant survival rate in relation to implant diameter and site of placement.MethodsThe data were collected from 186 patients treated between January 2019 and June 2021. All the implants were evaluated and restored after three months of implant placement. The early implant survival was calculated for different implant diameters with the odds ratio (OR).ResultsA total of 373 implants were placed. Implants were placed in the following areas: upper posterior area (UPA), n = 123, upper anterior area (UAA), n = 49, lower posterior area (LPA), n = 184, and lower anterior area (LAA), n = 17. Implants of the following diameters were placed: 3.5 mm (n = 129), 4.3 mm (n = 166), and 5 mm (n = 78). The overall early survival rate was 97.32% after three months of placement. The highest early survival rate was at LAA (100%) and the lowest early survival rate was at UAA (95.9%). The implants 5 mm in diameter had the highest early survival rate (98.72%), while the implants 3.5 mm in diameter had the lowest early survival rate (94.57%). The ORs of the early implant survival were 4.7 [95% confidence interval (CI): 0.96-23.05)] and 4.42 (95% CI: 0.53-36.61) for the 4.3 mm and 5 mm implants, respectively, with no statistical significance.ConclusionsThe implants placed in the oral cavity had acceptable survival rates regardless of implant diameter or site of placement.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Survival of conventional dental implants in the edentulous atrophic maxilla in combination with zygomatic implants: a 20-year retrospective study
    Vrielinck, Luc
    Blok, Jorden
    Politis, Constantinus
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2022, 8 (01)
  • [32] One-year performance of posterior narrow diameter implants in hyperglycemic and normo-glycemic patients—a pilot study
    Anton Friedmann
    Marianna Winkler
    Daniel Diehl
    Mehmet Selim Yildiz
    Hakan Bilhan
    Clinical Oral Investigations, 2021, 25 : 6707 - 6715
  • [33] Influence of crown-implant ratio on implant success rate of ultra-short dental implants: results of a 8-to 10-year retrospective study
    Malchiodi, Luciano
    Ricciardi, Giulia
    Salandini, Anna
    Caricasulo, Riccardo
    Cucchi, Alessandro
    Ghensi, Paolo
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (09) : 3213 - 3222
  • [34] Short Dental Implants (≤8.5 mm) versus Standard Dental Implants (≥10 mm): A One-Year Post-Loading Prospective Observational Study
    Pardo-Zamora, Guillermo
    Ortiz-Ruiz, Antonio Jose
    Camacho-Alonso, Fabio
    Martinez-Marco, Jose Francisco
    Molina-Gonzalez, Juan Manuel
    Pique-Clusella, Nuria
    Vicente-Hernandez, Ascension
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (11)
  • [35] REPORTS OF BACTERIAL FOOD POISONING IN THE RIYADH REGION OF SAUDI-ARABIA - A ONE-YEAR RETROSPECTIVE STUDY
    JARALLAH, JS
    KHOJA, TA
    IZMIRLY, MAG
    SAUDI MEDICAL JOURNAL, 1993, 14 (01) : 46 - 49
  • [36] Implants placed in immediate function in periodontally compromised sites: A five-year retrospective and one-year prospective study
    Malo, Paulo
    de Araujo Nobre, Miguel
    Rangert, Bo
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (06): : S86 - S95
  • [37] Implant survival and biologic complications of implant fixed complete dental prostheses: An up to 5-year retrospective study
    Chochlidakis, Konstantinos
    Ercoli, Carlo
    Einarsdottir, Erna
    Romeo, Davide
    Papaspyridakos, Panos
    Barmak, Abdul Basir
    Tsigarida, Alexandra
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 375 - 381
  • [38] One-year results of maxillary overdentures supported by 2 titanium-zirconium implants - implant survival rates and radiographic outcomes
    Zembic, Anja
    Tahmaseb, Ali
    Jung, Ronald E.
    Wismeijer, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (07) : e60 - e67
  • [39] A Four-Year Survival Rate Multicenter Prospective Clinical Study on 377 Implants: Correlations Between Implant Insertion Torque, Diameter, and Bone Quality
    Maiorana, Carlo
    Farronato, Davide
    Pieroni, Stefano
    Cicciu, Marco
    Andreoni, Dario
    Santoro, Franco
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (03) : E60 - E65
  • [40] Effect of implant design on survival and success rates -: A 10-year prospective study of ITI® Dental Implants
    Braegger, U
    Karoussis, IK
    Salvi, G
    Buergin, W
    Lang, NP
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A39 - A39