Performance evaluation of an auto-cascade refrigeration system using grey correlation theory and response surface methodology

被引:3
|
作者
Liu, Fazhu [1 ]
Ye, Wenlian [2 ]
Liu, Yingwen [1 ]
Yang, Peng [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermo Fluid Sci & Engn, MOE, Xian 710049, Peoples R China
[2] Lanzhou Univ Technol, Coll Energy & Power Engn, Key Lab Fluid Machinery & Syst, Lanzhou 730000, Gansu, Peoples R China
基金
中国国家自然科学基金;
关键词
EXERGY PERFORMANCE; ENERGY; CYCLE; POSITION; MIXTURE;
D O I
10.1080/23744731.2023.2203044
中图分类号
O414.1 [热力学];
学科分类号
摘要
This article focuses on evaluating and analyzing the performance of an autocascade refrigeration system with the zeotropic mixture of R600a/R1150/R14 refrigerants using grey correlation theory and response surface methodology (RSM). The correlation degree among various factors is analyzed using grey correlation theory. The interactive influences that have significant impacts on the six output parameters are illustrated, and a regression model is further validated by five confirmation parameters. The results show that the vapor quality of the evaporator outlet is the greatest factor that affecting the refrigerating capacity and coefficient of performance (COP). However, the evaporation temperature has the greatest effect on compressor's discharge temperature, pressure ratio, exergy destruction rates, and exergy efficiency. Lower vapor quality of the condenser outlet and condensation temperature can improve the performances of refrigerating capacity, COP, compressor's discharge temperature, compression ratio, total exergy destruction rate, and exergy efficiency based on the RSM results. The random five groups of validation parameters indicate that the errors between the predicted modeling and calculation results are all less than 5%, demonstrating that the RSM model has good predictability. The results achieved in this work will assist in the optimizing analysis and the application of cryogenic refrigerators.
引用
收藏
页码:491 / 507
页数:17
相关论文
共 50 条
  • [1] Performance prediction of an auto-cascade refrigeration system using multiple-algorithmic approaches
    Ye, Wenlian
    Liu, Yang
    Zhou, Zhongyou
    Hu, Lulu
    Liu, Yingwen
    ENERGY, 2025, 314
  • [2] Energy and exergy performance evaluation of a three-stage auto-cascade refrigeration system using low-GWP alternative refrigerants
    Qin, Yanbin
    Li, Nanxi
    Zhang, Hua
    Liu, Baolin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 126 : 66 - 75
  • [3] Experimental investigation of an ejector-enhanced auto-cascade refrigeration system
    Bai, Tao
    Yan, Gang
    Yu, Jianlin
    APPLIED THERMAL ENGINEERING, 2018, 129 : 792 - 801
  • [4] A novel online measurement method for compositions and energy performance of an auto-cascade refrigeration system
    Li, Yinlong
    Yan, Gang
    Jing, Dongliang
    Liu, Guoqiang
    Llopis, Rodrigo
    ENERGY, 2025, 318
  • [5] Theoretical performance comparison for two-stage auto-cascade refrigeration system using hydrocarbon refrigerants
    He, Yongning
    Wu, Huihong
    Liu, Yingying
    Wang, Tao
    Wu, Xuehong
    Cheng, Chuanxiao
    Jin, Tingxiang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 142 : 27 - 36
  • [6] Performance analysis of a modified ejector-enhanced auto-cascade refrigeration cycle
    Liu, Shuilong
    Bai, Tao
    Wei, Yuan
    Yu, Jianlin
    ENERGY, 2023, 265
  • [7] Study on the performance of an energy-efficient three-stage auto-cascade refrigeration system enhanced with a pressure regulator
    Qin, Yanbin
    Li, Nanxi
    Zhang, Hua
    Liu, Baolin
    ENERGY, 2022, 258
  • [8] Optimization analyses on the performance of an auto-cascade absorption refrigeration system operating with mixed refrigerants
    Zhou, Jinkun
    Le, Shengjian
    Wang, Qin
    Li, Dahong
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2018, 13 (03) : 212 - 217
  • [9] Experimental investigation on the concentration distribution behaviors of mixture in an ejector enhanced auto-cascade refrigeration system
    Bai, Tao
    Yan, Gang
    Yu, Jianlin
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 99 : 145 - 152
  • [10] Theoretical performance comparison for a regenerator-enhanced three-stage auto-cascade refrigeration system using different zeotropic mixed refrigerants
    He, Yongning
    Wu, Huihong
    Xu, Ke
    Zhang, Yeqiang
    Wang, Tao
    Wu, Xuehong
    Cheng, Chuanxiao
    Jin, Tingxiang
    ENERGY AND BUILDINGS, 2023, 283