fire-induced circulations; WRF-SFIRE; FireFlux2; experimental fires; fire modeling; fire wind; ATMOSPHERE INTERACTIONS; MODEL; SIMULATION;
D O I
10.3390/fire6090332
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
Despite recent advances in both coupled fire modeling and measurement techniques to sample the fire environment, the fire-atmosphere coupling mechanisms that lead to fast propagating wildfires remain poorly understood. This knowledge gap adversely affects fire management when wildland fires propagate unexpectedly rapidly and shift direction due to the fire impacts on local wind conditions. In this work, we utilized observational data from the FireFlux2 prescribed burn and numerical simulations performed with a coupled fire-atmosphere model WRF-SFIRE to assess the small-scale impacts of fire on local micrometeorology under moderate wind conditions (10-12 m/s). The FireFlux2 prescribed burn provided a comprehensive observational dataset with in situ meteorological observations as well as IR measurements of fire progression. To directly quantify the effects of fire-atmosphere interactions, two WRF-SFIRE simulations were executed. One simulation was run in a two-way coupled mode in which the heat and moisture fluxes emitted from the fire were injected into the atmosphere, and the other simulation was performed in a one-way coupled mode for which the atmosphere was not affected by the fire. The difference between these two simulations was used to analyze and quantify the fire impacts on the atmospheric circulation at different sections of the fire front. The fire-released heat fluxes resulted in vertical velocities as high as 10.8 m/s at the highest measurement level (20 m above ground level) gradually diminishing with height and dropping to 7.9 m/s at 5.77 m. The fire-induced horizontal winds indicated the strongest fire-induced flow at the lowest measurement levels (as high as 3.3 m/s) gradually decreasing to less than 1 m/s at 20 m above ground level. The analysis of the simulated flow indicates significant differences between the fire-induced circulation at the fire head and on the flanks. The fire-induced circulation was much stronger near the fire head than at the flanks, where the fire did not produce particularly strong cross-fire flow and did not significantly change the lateral fire progression. However, at the head of the fire the fire-induced winds blowing across the front were the strongest and significantly accelerated fire progression. The two-way coupled simulation including the fire-induced winds produced 36.2% faster fire propagation than the one-way coupled run, and more realistically represented the fire progression.
引用
收藏
页数:19
相关论文
共 8 条
  • [1] Probability analysis considering the temporal properties of fire-induced domino effects
    Zhou, Jianfeng
    Reniers, Genserik
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2024, 92
  • [2] Dynamic analysis for fire-induced domino effects in chemical process industries
    Huang, Kongxing
    Chen, Guohua
    Khan, Faisal
    Yang, Yunfeng
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2021, 148 : 686 - 697
  • [3] Fire-Induced Damage and Postfire Analysis of the Compression Properties of Cross-Laminated Timber
    Loh, Thomas W.
    Barnett, Jonathan R.
    Zhang, Guomin Kevin
    Nguyen, Kate T. Q.
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2024, 36 (03)
  • [4] Atmospheric dynamics and fire-induced phenomena: Insights from a comprehensive analysis of the Serta wildfire event
    Menezes, I. C.
    Lopes, D.
    Fernandes, A. P.
    Borrego, C.
    Viegas, D. X.
    Miranda, A. I.
    ATMOSPHERIC RESEARCH, 2024, 310
  • [5] Numerical analysis of the performance of a PID-controlled air curtain for fire-induced smoke confinement in a tunnel configuration
    Yu, Longxing
    Chen, Yinnan
    Chen, Shuo
    Zhang, Yuxuan
    Zhang, Hao
    Liu, Chunxiang
    FIRE SAFETY JOURNAL, 2023, 141
  • [6] Analysis of uncertainty propagation path of fire-induced domino effect based on an approach of layered fuzzy Petri nets e
    Guo, Liping
    Wang, Zhirong
    CHEMICAL ENGINEERING SCIENCE, 2023, 268
  • [7] Analysis of emergency response actions for preventing fire-induced domino effects based on an approach of reversed fuzzy Petri-net
    Zhou, Jianfeng
    Reniers, Genserik
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2017, 47 : 169 - 173
  • [8] Assessment of fire emission inventories during the South American Biomass Burning Analysis (SAMBBA) experiment
    Pereira, Gabriel
    Siqueira, Ricardo
    Rosario, Nilton E.
    Longo, Karla L.
    Freitas, Saulo R.
    Cardozo, Francielle S.
    Kaiser, Johannes W.
    Wooster, Martin J.
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2016, 16 (11) : 6961 - 6975