Quasi-static pipeline in electroconvulsive therapy computational modeling

被引:4
作者
Unal, Gozde [1 ]
Poon, Cynthia [1 ]
FallahRad, Mohamad [1 ]
Thahsin, Myesha [1 ]
Argyelan, Miklos [2 ]
Bikson, Marom [1 ]
机构
[1] CUNY, Dept Biomed Engn, New York, NY 10031 USA
[2] North Shore Long Isl Jewish Hlth Syst, Feinstein Inst Med Res, Ctr Neurosci, Manhasset, NY 11030 USA
基金
美国国家卫生研究院;
关键词
DEEP BRAIN-STIMULATION; SEIZURE THRESHOLD; ELECTRICAL-PROPERTIES; UNIFORM ASSUMPTION; SKIN IMPEDANCE; DC STIMULATION; ECT; STIMULUS; EXCITATION; TISSUE;
D O I
10.1016/j.brs.2023.03.007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Computational models of current flow during Electroconvulsive Therapy (ECT) rely on the quasi-static assumption, yet tissue impedance during ECT may be frequency specific and change adaptively to local electric field intensity.Objectives: We systematically consider the application of the quasi-static pipeline to ECT under conditions where 1) static impedance is measured before ECT and 2) during ECT when dynamic impedance is measured. We propose an update to ECT modeling accounting for frequency-dependent impedance.Methods: The frequency content on an ECT device output is analyzed. The ECT electrode-body impedance under low-current conditions is measured with an impedance analyzer. A framework for ECT modeling under quasi-static conditions based on a single device-specific frequency (e.g., 1 kHz) is proposed.Results: Impedance using ECT electrodes under low-current is frequency dependent and subject specific, and can be approximated at >100 Hz with a subject-specific lumped parameter circuit model but at <100 Hz increased non-linearly. The ECT device uses a 2 mA 800 Hz test signal and reports a static impedance that approximate 1 kHz impedance. Combined with prior evidence suggesting that conductivity does not vary significantly across ECT output frequencies at high-currents (800-900 mA), we update the adaptive pipeline for ECT modeling centered at 1 kHz frequency. Based on individual MRI and adaptive skin properties, models match static impedance (at 2 mA) and dynamic impedance (at 900 mA) of four ECT subjects.Conclusions: By considering ECT modeling at a single representative frequency, ECT adaptive and nonadaptive modeling can be rationalized under a quasi-static pipeline.& COPY; 2023 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:607 / 618
页数:12
相关论文
共 30 条
  • [21] Effect of Anatomical Variability on Electric Field Characteristics of Electroconvulsive Therapy and Magnetic Seizure Therapy: A Parametric Modeling Study
    Deng, Zhi-De
    Lisanby, Sarah H.
    Peterchev, Angel V.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2015, 23 (01) : 22 - 31
  • [22] Effects of cryopreservation, decellularization and novel extracellular matrix conditioning on the quasi-static and time-dependent properties of the pulmonary valve leaflet
    Converse, Gabriel L.
    Armstrong, Matt
    Quinn, Rachael W.
    Buse, Eric E.
    Cromwell, Michael L.
    Moriarty, Sara J.
    Lofland, Gary K.
    Hilbert, Stephen L.
    Hopkins, Richard A.
    ACTA BIOMATERIALIA, 2012, 8 (07) : 2722 - 2729
  • [23] Rate-dependent mechanical behaviour of semilunar valves under biaxial deformation: From quasi-static to physiological loading rates
    Anssari-Benam, Afshin
    Tseng, Yuan-Tsan
    Holzapfel, Gerhard A.
    Bucchi, Andrea
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 104
  • [24] Quasi-static piezoelectric strain and recoverable energy at a low biased field in Sr2+ substituted electrostrictive BZT ceramic
    Manna, Aditi
    Kushvaha, D. K.
    Rout, S. K.
    Tiwari, B.
    Yoshimura, Takeshi
    BULLETIN OF MATERIALS SCIENCE, 2023, 47 (01)
  • [25] Real-time electrical impedance monitoring of carbon fiber-reinforced polymer laminates undergoing quasi-static indentation
    Almuhammadi, Khaled
    Yudhanto, Arief
    Lubineau, Gilles
    COMPOSITE STRUCTURES, 2019, 207 : 255 - 263
  • [26] A quasi-static method for measuring the deactivation rate constants of O2(a1Δg) in gas phase by IR radiation decay
    Du, Shuyan
    Leng, Jing
    Wang, Junhui
    Yang, Heping
    Sha, Guohe
    Zhang, Cunhao
    CHEMICAL PHYSICS LETTERS, 2011, 504 (4-6) : 241 - 244
  • [27] Amplitude-determined seizure-threshold, electric field modeling, and electroconvulsive therapy antidepressant and cognitive outcomes
    Abbott, Christopher C.
    Miller, Jeremy
    Farrar, Danielle
    Argyelan, Miklos
    Lloyd, Megan
    Squillaci, Taylor
    Kimbrell, Brian
    Ryman, Sephira
    Jones, Thomas R.
    Upston, Joel
    Quinn, Davin K.
    Peterchev, Angel V.
    Erhardt, Erik
    Datta, Abhishek
    Mcclintock, Shawn M.
    Deng, Zhi-De
    NEUROPSYCHOPHARMACOLOGY, 2024, 49 (04) : 640 - 648
  • [28] Enhancing Electric Field Distribution in the Pancreas for Improved TTFields Therapy: A Computational Modeling Investigation
    Zheng, Mengxuan
    Wang, Yuhao
    Chen, Sheng
    Suo, Yuanzhen
    Yu, Jing
    Zhang, Xiaotong
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (09) : 2612 - 2619
  • [29] Cost-Effectiveness Modeling of Repetitive Transcranial Magnetic Stimulation Compared to Electroconvulsive Therapy for Treatment-Resistant Depression in Singapore
    Zhao, Ying Jiao
    Tor, Phern Chern
    Khoo, Ai Leng
    Teng, Monica
    Lim, Boon Peng
    Mok, Yee Ming
    NEUROMODULATION, 2018, 21 (04): : 376 - 382
  • [30] Upper Cervical Spine Loading Simulating a Dynamic Low-Speed Collision Significantly Increases the Risk of Pain Compared to Quasi-Static Loading With Equivalent Neck Kinematics
    Holsgrove, Timothy P.
    Jaumard, Nicolas V.
    Zhu, Nina
    Stiansen, Nicholas S.
    Welch, William C.
    Winkelstein, Beth A.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (12):