Straightforward quantification of endogenous steroids with liquid chromatography-tandem mass spectrometry: Comparing calibration approaches

被引:9
|
作者
Visconti, Gioele [1 ,2 ]
de Figueiredo, Miguel [1 ,2 ]
Salamin, Olivier [4 ,5 ,6 ,7 ,8 ]
Boccard, Julien [1 ,2 ,3 ]
Vuilleumier, Nicolas [9 ]
Nicoli, Raul [5 ,6 ,7 ,8 ]
Kuuranne, Tiia [5 ,7 ,8 ]
Rudaz, Serge [1 ,2 ,3 ,6 ]
机构
[1] Univ Geneva, Sch Pharmaceut Sci, CMU Rue Michel Servet 1, Geneva, Switzerland
[2] Univ Geneva, Inst Pharmaceut Sci Western Switzerland, CMU Rue Michel Servet 1, Geneva, Switzerland
[3] Swiss Ctr Appl Human Toxicol SCAHT, Basel, Switzerland
[4] Univ Lausanne, Inst Sport Sci, Ctr Res & Expertise Antidoping Sci REDs, Lausanne, Switzerland
[5] Lausanne Univ Hosp, Univ Ctr Legal Med, Swiss Lab Doping Anal, Lausanne, Eswatini
[6] Lausanne Univ Hosp, Univ Ctr Legal Med, Swiss Lab Doping Anal, Geneva, Switzerland
[7] Univ Lausanne, Lausanne, Switzerland
[8] Univ Lausanne, Geneva, Switzerland
[9] Geneva Univ Hosp HUG, Dept Genet, Lab Med, Geneva, Switzerland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2023年 / 1226卷
关键词
Switzerland; Quantification; External calibration; Internal calibration; Steroids; LC-MS; LC-MS/MS; INTERNAL CALIBRATION; METHOD VALIDATION; PLASMA; PRECISION; URINE; DRUGS; SERUM;
D O I
10.1016/j.jchromb.2023.123778
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Different calibration strategies are used in liquid chromatography hyphenated to mass spectrometry (LC-MS) bioanalysis. Currently, the surrogate matrix and surrogate analyte represent the most widely used approaches to compensate for the lack of analyte-free matrices in endogenous compounds quantification. In this context, there is a growing interest in rationalizing and simplifying quantitative analysis using a one-point concentration level of stable isotope-labeled (SIL) standards as surrogate calibrants. Accordingly, an internal calibration (IC) can be applied when the instrument response is translated into analyte concentration via the analyte-to-SIL ratio performed directly in the study sample. Since SILs are generally used as internal standards to normalize variability between authentic study sample matrix and surrogate matrix used for the calibration, IC can be calculated even if the calibration protocol was achieved for an external calibration (EC). In this study, a complete dataset of a published and fully validated method to quantify an extended steroid profile in serum was recomputed by adapting the role of SIL internal standards as surrogate calibrants. Using the validation samples, the quantitative performances for IC were comparable with the original method, showing acceptable trueness (79%-115%) and precision (0.8%-11.8%) for the 21 detected steroids. The IC methodology was then applied to human serum samples (n = 51) from healthy women and women diagnosed with mild hyperandrogenism, showing high agreement (R2 > 0.98) with the concentrations obtained using the conventional quantification based on EC. For IC, Passing-Bablok regression showed proportional biases between -15.0% and 11.3% for all quantified steroids, with an average difference of -5.8% compared to EC. These results highlight the reliability and the advantages of implementing IC in clinical laboratories routine to simplify quantification in LC-MS bioanalysis, especially when a large panel of analytes is monitored.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Simultaneous quantification of tiloronoxim and tilorone in human urine by liquid chromatography-tandem mass spectrometry
    Zhang, Xianhua
    Yang, Li
    Zhai, Suodi
    Duan, Jingli
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 875 (02): : 349 - 357
  • [32] Detection and confirmation of 60 anabolic and androgenic steroids in equine plasma by liquid chromatography-tandem mass spectrometry with instant library searching
    Liu, Ying
    Uboh, Cornelius E.
    Soma, Lawrence R.
    Li, Xiaoqing
    Guan, Fuyu
    You, Youwen
    Rudy, Jeffrey A.
    Chen, Jin-Wen
    DRUG TESTING AND ANALYSIS, 2011, 3 (01) : 54 - 67
  • [33] Assay of steroids by liquid chromatography-tandem mass spectrometry in monitoring 21-hydroxylase deficiency
    Dahl, Sandra R.
    Nermoen, Ingrid
    Bronstad, Ingeborg
    Husebye, Eystein S.
    Lovas, Kristian
    Thorsby, Per M.
    ENDOCRINE CONNECTIONS, 2018, 7 (12): : 1542 - 1550
  • [34] Analysis of thyroid hormones in serum by liquid chromatography-tandem mass spectrometry
    Wang, Dongli
    Stapleton, Heather M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (05) : 1831 - 1839
  • [35] Special Considerations for Liquid Chromatography-Tandem Mass Spectrometry Method Development
    Rappold, Brian A.
    CLINICS IN LABORATORY MEDICINE, 2018, 38 (03) : 539 - +
  • [36] Therapeutic drug monitoring of topiramate by liquid chromatography-tandem mass spectrometry
    Matar, Kamal M.
    CLINICA CHIMICA ACTA, 2010, 411 (9-10) : 729 - 734
  • [37] Determination of voriconazole in human plasma by liquid chromatography-tandem mass spectrometry
    Teng, G-Sh.
    Zhao, L. -Z.
    Li, X.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2016, 48 (01): : 147 - 152
  • [38] Determination of salivary testosterone and androstendione by liquid chromatography-tandem mass spectrometry
    Turpeinen, Ursula
    Hamalainen, Esa
    Haanpaa, Mikko
    Dunkel, Leo
    CLINICA CHIMICA ACTA, 2012, 413 (5-6) : 594 - 599
  • [39] A method for quantification of human transporter proteins by liquid chromatography-tandem mass spectrometry
    Hou, Zhe
    Zhang, Lei
    Guo, Xuan
    Li, Hui
    Li, Xiaodong
    Dong, Jing
    Zhang, Guangqin
    Liu, Dongyang
    SEPARATION SCIENCE PLUS, 2023, 6 (03)
  • [40] Sensitive quantification of rifaximin in human plasma by liquid chromatography-tandem mass spectrometry
    Zhang, Xianhua
    Duan, Jingli
    Li, Ke
    Zhou, Liya
    Zhai, Suodi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2): : 348 - 355