Straightforward quantification of endogenous steroids with liquid chromatography-tandem mass spectrometry: Comparing calibration approaches

被引:9
|
作者
Visconti, Gioele [1 ,2 ]
de Figueiredo, Miguel [1 ,2 ]
Salamin, Olivier [4 ,5 ,6 ,7 ,8 ]
Boccard, Julien [1 ,2 ,3 ]
Vuilleumier, Nicolas [9 ]
Nicoli, Raul [5 ,6 ,7 ,8 ]
Kuuranne, Tiia [5 ,7 ,8 ]
Rudaz, Serge [1 ,2 ,3 ,6 ]
机构
[1] Univ Geneva, Sch Pharmaceut Sci, CMU Rue Michel Servet 1, Geneva, Switzerland
[2] Univ Geneva, Inst Pharmaceut Sci Western Switzerland, CMU Rue Michel Servet 1, Geneva, Switzerland
[3] Swiss Ctr Appl Human Toxicol SCAHT, Basel, Switzerland
[4] Univ Lausanne, Inst Sport Sci, Ctr Res & Expertise Antidoping Sci REDs, Lausanne, Switzerland
[5] Lausanne Univ Hosp, Univ Ctr Legal Med, Swiss Lab Doping Anal, Lausanne, Eswatini
[6] Lausanne Univ Hosp, Univ Ctr Legal Med, Swiss Lab Doping Anal, Geneva, Switzerland
[7] Univ Lausanne, Lausanne, Switzerland
[8] Univ Lausanne, Geneva, Switzerland
[9] Geneva Univ Hosp HUG, Dept Genet, Lab Med, Geneva, Switzerland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2023年 / 1226卷
关键词
Switzerland; Quantification; External calibration; Internal calibration; Steroids; LC-MS; LC-MS/MS; INTERNAL CALIBRATION; METHOD VALIDATION; PLASMA; PRECISION; URINE; DRUGS; SERUM;
D O I
10.1016/j.jchromb.2023.123778
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Different calibration strategies are used in liquid chromatography hyphenated to mass spectrometry (LC-MS) bioanalysis. Currently, the surrogate matrix and surrogate analyte represent the most widely used approaches to compensate for the lack of analyte-free matrices in endogenous compounds quantification. In this context, there is a growing interest in rationalizing and simplifying quantitative analysis using a one-point concentration level of stable isotope-labeled (SIL) standards as surrogate calibrants. Accordingly, an internal calibration (IC) can be applied when the instrument response is translated into analyte concentration via the analyte-to-SIL ratio performed directly in the study sample. Since SILs are generally used as internal standards to normalize variability between authentic study sample matrix and surrogate matrix used for the calibration, IC can be calculated even if the calibration protocol was achieved for an external calibration (EC). In this study, a complete dataset of a published and fully validated method to quantify an extended steroid profile in serum was recomputed by adapting the role of SIL internal standards as surrogate calibrants. Using the validation samples, the quantitative performances for IC were comparable with the original method, showing acceptable trueness (79%-115%) and precision (0.8%-11.8%) for the 21 detected steroids. The IC methodology was then applied to human serum samples (n = 51) from healthy women and women diagnosed with mild hyperandrogenism, showing high agreement (R2 > 0.98) with the concentrations obtained using the conventional quantification based on EC. For IC, Passing-Bablok regression showed proportional biases between -15.0% and 11.3% for all quantified steroids, with an average difference of -5.8% compared to EC. These results highlight the reliability and the advantages of implementing IC in clinical laboratories routine to simplify quantification in LC-MS bioanalysis, especially when a large panel of analytes is monitored.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Accurate quantification of endogenous N-acylethanolamides by chemical isotope labeling coupled with liquid chromatography-tandem mass spectrometry
    Chen, Yan-Qing
    Shen, Hong
    Yang, Ru-Jie
    Wan, Jian-Bo
    ANALYTICA CHIMICA ACTA, 2021, 1179
  • [22] A Review on Liquid Chromatography-Tandem Mass Spectrometry Methods for Rapid Quantification of Oncology Drugs
    Wong, Andrea Li-Ann
    Xiang, Xiaoqiang
    Ong, Pei Shi
    Mitchell, Ee Qin Ying
    Syn, Nicholas
    Wee, Ian
    Kumar, Alan Prem
    Yong, Wei Peng
    Sethi, Gautam
    Goh, Boon Cher
    Ho, Paul Chi-Lui
    Wang, Lingzhi
    PHARMACEUTICS, 2018, 10 (04):
  • [23] Confirmatory analysis of steroids in muscle using liquid chromatography-tandem mass spectrometry
    Pedersen, Mikael
    Andersen, Jens Hinge
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2011, 28 (04): : 428 - 437
  • [24] Identification and quantification of fox meat in meat products by liquid chromatography-tandem mass spectrometry
    Zhang, Yingying
    Liu, Mengyao
    Wang, Shouwei
    Kang, Chaodi
    Zhang, Mingyue
    Li, Yingying
    FOOD CHEMISTRY, 2022, 372
  • [25] Rapid quantification of murine bile acids using liquid chromatography-tandem mass spectrometry
    Hermeling, Sven
    Plagge, Johannes
    Krautbauer, Sabrina
    Ecker, Josef
    Burkhardt, Ralph
    Liebisch, Gerhard
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025, 417 (04) : 687 - 696
  • [26] Liquid chromatography-tandem mass spectrometry for clinical diagnostics
    不详
    NATURE REVIEWS METHODS PRIMERS, 2022, 2 (01):
  • [27] Simultaneous Quantification of Adalimumab and Infliximab in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry
    Jourdil, Jean-Francois
    Nemoz, Benjamin
    Gautier-Veyret, Elodie
    Romero, Charlotte
    Stanke-Labesque, Francoise
    THERAPEUTIC DRUG MONITORING, 2018, 40 (04) : 417 - 424
  • [28] A liquid chromatography-tandem mass spectrometry assay for the detection and quantification of trehalose in biological samples
    Kretschmer, Philip M.
    Bannister, Austin M.
    O'Brien, Molly K.
    MacManus-Spencer, Laura A.
    Paulick, Margot G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1033 : 9 - 16
  • [29] Quantification of chlordesmethyldiazepam by liquid chromatography-tandem mass spectrometry: application to a cloxazolam bioequivalence study
    Oliveira-Silva, Diogo
    Oliveira, Celso H.
    Mendes, Gustavo D.
    Galvinas, Paulo Alexandre R.
    Barrientos-Astigarraga, Rafael E.
    De Nucci, Gilberto
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (12) : 1266 - 1275
  • [30] Ocrelizumab quantitation by liquid chromatography-tandem mass spectrometry
    Hallin, Erik I.
    Serkland, Trond Traetteberg
    Myhr, Kjell-Morten
    Torkildsen, Oivind Grytten
    Skrede, Silje
    JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB, 2022, 25 : 53 - 60